Model based detection of hydrogen leaks in a fuel cell stack

被引:0
|
作者
Ingimundarson, Ari [1 ]
Stefanopoulou, Anna G. [1 ]
McKay, Denise [1 ]
机构
[1] Tech Univ Catalonia, Automat Control Dept, Terrassa 08222, Spain
关键词
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Hydrogen leaks are potentially dangerous faults in fuel cell systems. The paper presents an approach to detect hydrogen leaks. The method is applicable during startup and shutdown as well as normal operating conditions. The method relies on simple mass balance equations but takes into account the natural leak of the stack and humidity. Hydrogen leak detection without using relative humidity sensors is specially studied. In that case, adaptive alarm thresholds are given so that false alarms due to the lack of humidity sensors are eliminated. The validity of the method is also discussed in terms of common hydrogen supply system configurations. The detection method is validated on an real fuel cell laboratory rig where leaks could be introduced in a controlled manner.
引用
收藏
页码:1017 / 1022
页数:6
相关论文
共 50 条
  • [1] Model-based detection of hydrogen leaks in a fuel cell stack
    Ingimundarson, Ari
    Stefanopoulou, Anna G.
    McKay, Denise A.
    [J]. IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2008, 16 (05) : 1004 - 1012
  • [2] Optimization of a fuel cell stack fueled by hydrogen-based mixtures
    Grigor'ev, S. A.
    Fateev, V. N.
    Sister, V. G.
    Rusanov, V. D.
    [J]. DOKLADY PHYSICAL CHEMISTRY, 2006, 411 (1) : 293 - 296
  • [3] Optimization of a fuel cell stack fueled by hydrogen-based mixtures
    S. A. Grigor’ev
    V. N. Fateev
    V. G. Sister
    V. D. Rusanov
    [J]. Doklady Physical Chemistry, 2006, 411 : 293 - 296
  • [4] Electrochemical hydrogen pump for recirculation of hydrogen in a fuel cell stack
    Barbir, Frano
    Gorgun, Haluk
    [J]. JOURNAL OF APPLIED ELECTROCHEMISTRY, 2007, 37 (03) : 359 - 365
  • [5] Electrochemical hydrogen pump for recirculation of hydrogen in a fuel cell stack
    Frano Barbir
    Haluk Görgün
    [J]. Journal of Applied Electrochemistry, 2007, 37 : 359 - 365
  • [6] On-line model-based fault detection and isolation for PEM fuel cell stack systems
    Rosich, A.
    Sarrate, R.
    Nejjari, F.
    [J]. APPLIED MATHEMATICAL MODELLING, 2014, 38 (11-12) : 2744 - 2757
  • [7] Hydrogen pressure drop characteristics in a fuel cell stack
    Pei, PC
    Ouyang, M
    Feng, W
    Lu, LG
    Huang, HY
    Zhang, JH
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2006, 31 (03) : 371 - 377
  • [8] Fault detection and isolation for PEM fuel cell stack with independent RBF model
    Kamal, M. M.
    Yu, D. W.
    Yu, D. L.
    [J]. ENGINEERING APPLICATIONS OF ARTIFICIAL INTELLIGENCE, 2014, 28 : 52 - 63
  • [9] Optimization of Fuel Cell Stack Consistency Based on Multi-Model
    Zeng, Yijin
    Huang, Jian
    Wang, Zhiliang
    Li, Junxiong
    Yi, Yahui
    [J]. SCIENTIFIC PROGRAMMING, 2022, 2022
  • [10] A dynamic voltage model of a fuel cell stack considering the effects of hydrogen purge operation
    Hou, Yongping
    Shen, Caoyuan
    Yang, Zhihua
    He, Yuntang
    [J]. RENEWABLE ENERGY, 2012, 44 : 246 - 251