Semiconductor and thermoluminescent dosimetry of pulsed soft X ray plasma sources

被引:9
|
作者
Krása, J [1 ]
Cejnarová, A
Juha, L
Ryé, L
Scholz, M
Kubes, P
机构
[1] ASCR, Inst Phys, Dept Gas Lasers, Prague 18221 8, Czech Republic
[2] Inst Plasma Phys & Laser Microfus, PL-00908 Warsaw, Poland
[3] Czech Tech Univ, Prague 16627 6, Czech Republic
关键词
D O I
10.1093/oxfordjournals.rpd.a005906
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A multichannel detection system having a dynamic range of approximate to1 X 10(-9) Gy-20Gy was developed with the use of commercially produced Si-photodiodes and TLDs for accurate measurement of X ray energy emitted from plasma-focus facility and from laser-produced plasmas. The proof of linearity of the employed detectors accomplished by a comparison of their responses to a broad band spectrum of X rays emitted from plasmas, is reported. It is demonstrated that TLDs irradiated with no protective filter show an incorrect response due to overloading in the sub-keV range and repopulation of dosimetric peaks induced by the UV radiation. The measurement of the power of undesirable secondary X ray sources driven by the primary plasma inside the interaction chamber was performed on the basis of analysis of space dependence of X ray intensity with respect to the assumed r(-2) decrease in the intensity far away from the plasma.
引用
收藏
页码:429 / 432
页数:4
相关论文
共 50 条
  • [41] Evolving approaches to pulsed X-ray sources
    Ware, KD
    Bell, DE
    Gullickson, RL
    Vitkovitsky, I
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2002, 30 (05) : 1733 - 1741
  • [42] Evolving approaches to pulsed X-ray sources
    Ware, KD
    Bell, DE
    Gullickson, RL
    Vitkovitsky, I
    PPPS-2001: PULSED POWER PLASMA SCIENCE 2001, VOLS I AND II, DIGEST OF TECHNICAL PAPERS, 2001, : 350 - 353
  • [43] Plasma-filled diode with a rod anode for repetitive pulsed X-ray sources
    Kovalchuk, B. M.
    Zherlitsyn, A. A.
    Tsoy, N. V.
    LASER AND PARTICLE BEAMS, 2016, 34 (04) : 631 - 636
  • [44] X-ray scattering applications using pulsed x-ray sources
    Larson, BC
    TIME STRUCTURE OF X-RAY SOURCES AND ITS APPLICATIONS, 1998, 3451 : 10 - 21
  • [45] ANALYZERS OF SOFT X-RAYS FROM PULSED SOURCES
    ALTYNTSEV, AT
    KRASOV, VI
    MAKSYUTOV, IB
    PAPERNYI, VL
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1978, 21 (06) : 1628 - 1630
  • [46] A PULSED PLASMA X-RAY SOURCE FOR X-RAY-LITHOGRAPHY
    MATTHEWS, S
    DAHLBACKA, G
    STRINGFIELD, R
    COOPER, R
    SZE, H
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1982, 129 (03) : C112 - C113
  • [47] Robust liquid metal collector mirror for EUV and soft X-ray plasma sources
    Fahy, Kenneth
    O'Reilly, Fergal
    Scally, Enda
    Sheridan, Paul
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS V, 2010, 7802
  • [48] Application of laser plasma soft X-ray and EUV sources in micro- and nanotechnology
    Fiedorowicz, Henryk
    Bartnik, Andrzej
    Jakubczak, Krzysztof
    Jarocki, Roman
    Juha, Libor
    LASER TECHNOLOGY VIII: APPLICATIONS OF LASERS, 2007, 6598
  • [49] Optical systems for laser-produced plasma EUV and soft X-ray sources
    Bartnik, A.
    Fiedorowicz, H.
    Wachulak, P.
    Fok, T.
    Wegrzynski, L.
    21ST CZECH-POLISH-SLOVAK OPTICAL CONFERENCE ON WAVE AND QUANTUM ASPECTS OF CONTEMPORARY OPTICS, 2018, 10976
  • [50] Stability of droplet-target laser-plasma soft x-ray sources
    Hemberg, O
    Hansson, BAM
    Berglund, M
    Hertz, HM
    JOURNAL OF APPLIED PHYSICS, 2000, 88 (09) : 5421 - 5425