Semiconductor and thermoluminescent dosimetry of pulsed soft X ray plasma sources

被引:9
|
作者
Krása, J [1 ]
Cejnarová, A
Juha, L
Ryé, L
Scholz, M
Kubes, P
机构
[1] ASCR, Inst Phys, Dept Gas Lasers, Prague 18221 8, Czech Republic
[2] Inst Plasma Phys & Laser Microfus, PL-00908 Warsaw, Poland
[3] Czech Tech Univ, Prague 16627 6, Czech Republic
关键词
D O I
10.1093/oxfordjournals.rpd.a005906
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A multichannel detection system having a dynamic range of approximate to1 X 10(-9) Gy-20Gy was developed with the use of commercially produced Si-photodiodes and TLDs for accurate measurement of X ray energy emitted from plasma-focus facility and from laser-produced plasmas. The proof of linearity of the employed detectors accomplished by a comparison of their responses to a broad band spectrum of X rays emitted from plasmas, is reported. It is demonstrated that TLDs irradiated with no protective filter show an incorrect response due to overloading in the sub-keV range and repopulation of dosimetric peaks induced by the UV radiation. The measurement of the power of undesirable secondary X ray sources driven by the primary plasma inside the interaction chamber was performed on the basis of analysis of space dependence of X ray intensity with respect to the assumed r(-2) decrease in the intensity far away from the plasma.
引用
收藏
页码:429 / 432
页数:4
相关论文
共 50 条
  • [31] Investigations on calibration sources for soft-x-ray plasma spectroscopy and impurity monitors
    Schumacher, U
    Asmussen, K
    Fussmann, G
    Liebsch, T
    Neu, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (08): : 2826 - 2830
  • [32] Use of thermoluminescent dosimetry (TLD) for quality assurance of orthovoltage X-ray therapy machines
    Nelson, V. K.
    McLean, I. D.
    Holloway, L.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 908 - 911
  • [33] A windowless ionization chamber for soft X-ray dosimetry
    Pszona, S.
    Wincel, K.
    Zareba, B.
    Bulski, W.
    Ulkowski, P.
    Traczyk, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2010, 268 (01): : 92 - 96
  • [34] A COMPARISON OF 3 DETECTORS FOR SOFT-X-RAY DOSIMETRY
    MEGER, CM
    PEARSON, DW
    DELUCA, PM
    WELLS, GM
    REDAELLI, R
    CERRINA, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 266 (1-3): : 608 - 611
  • [35] Soft X-ray transients as ultraluminous X-ray sources
    Lee, CH
    Brown, GE
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF JAPAN, 2004, 56 (02) : 347 - 351
  • [36] A pulsed monoenergetic soft X-ray source
    Nagornyi, VI
    Nefedov, YY
    Usenko, PL
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1996, 39 (01) : 122 - 126
  • [37] X-ray microscopy with compact pulsed sources
    Richardson, M
    Kado, M
    Torres, D
    Yamamoto, Y
    Friedman, H
    Rajyaguru, J
    Muszynski, M
    EXPLOITING NEW IMAGE SOURCES AND SENSORS, 26TH AIPR WORKSHOP, 1998, 3240 : 29 - 35
  • [38] An hybrid detector GEM-ASIC for 2-D soft X-ray imaging for laser produced plasma and pulsed sources
    Pacella, D.
    Claps, G.
    De Angelis, R.
    Murtas, F.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [39] Sample Injection for Pulsed X-ray Sources
    DePonte, Daniel P.
    Nass, Karol
    Stellato, Francesco
    Liang, Mengning
    Chapman, Henry N.
    ADVANCES IN X-RAY FREE-ELECTRON LASERS: RADIATION SCHEMES, X-RAY OPTICS, AND INSTRUMENTATION, 2011, 8078
  • [40] INTENSE-PULSED PLASMA X-RAY SOURCES FOR LITHOGRAPHY - MASK DAMAGE EFFECTS
    HYMAN, HA
    BALLANTYNE, A
    FRIEDMAN, HW
    REILLY, DA
    SOUTHWORTH, RC
    DYM, CL
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1982, 21 (04): : 1012 - 1016