Semiconductor and thermoluminescent dosimetry of pulsed soft X ray plasma sources

被引:9
|
作者
Krása, J [1 ]
Cejnarová, A
Juha, L
Ryé, L
Scholz, M
Kubes, P
机构
[1] ASCR, Inst Phys, Dept Gas Lasers, Prague 18221 8, Czech Republic
[2] Inst Plasma Phys & Laser Microfus, PL-00908 Warsaw, Poland
[3] Czech Tech Univ, Prague 16627 6, Czech Republic
关键词
D O I
10.1093/oxfordjournals.rpd.a005906
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A multichannel detection system having a dynamic range of approximate to1 X 10(-9) Gy-20Gy was developed with the use of commercially produced Si-photodiodes and TLDs for accurate measurement of X ray energy emitted from plasma-focus facility and from laser-produced plasmas. The proof of linearity of the employed detectors accomplished by a comparison of their responses to a broad band spectrum of X rays emitted from plasmas, is reported. It is demonstrated that TLDs irradiated with no protective filter show an incorrect response due to overloading in the sub-keV range and repopulation of dosimetric peaks induced by the UV radiation. The measurement of the power of undesirable secondary X ray sources driven by the primary plasma inside the interaction chamber was performed on the basis of analysis of space dependence of X ray intensity with respect to the assumed r(-2) decrease in the intensity far away from the plasma.
引用
收藏
页码:429 / 432
页数:4
相关论文
共 50 条
  • [11] A COMPARISON OF SEMICONDUCTOR AND THERMOLUMINESCENT DOSIMETERS FOR INVIVO DOSIMETRY
    AUKETT, RJ
    BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (766): : 947 - 952
  • [12] Design, fabrication and characterization of an x-ray bolometer for pulsed plasma x-ray sources
    Mahadevan, S
    Chakera, JA
    Vaidya, PP
    Balasubramanian, D
    Kaushik, OP
    Naik, PA
    Rangarajan, LM
    Gupta, PD
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2005, 16 (11) : 2287 - 2291
  • [14] LASER-PLASMA SOURCES OF SOFT-X-RAY RADIATION
    ANANIN, OB
    BYKOVSKII, YA
    EREMIN, YV
    ZHURAVLEV, AA
    ZNAMENSKII, VY
    KOVALENKO, AV
    NOVIKOV, IK
    FROLOV, SP
    LASER PHYSICS, 1994, 4 (03) : 521 - 531
  • [15] Radiance of intense impulse soft-X-ray plasma sources
    Bobashev, SV
    CONTRIBUTIONS TO PLASMA PHYSICS, 2000, 40 (1-2) : 77 - 80
  • [16] PULSED X-RAY SOURCES
    BELAGO, VA
    BUDTSEV, VY
    FILIPPENKO, AS
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1980, 23 (02) : 499 - 501
  • [17] Initial thermoluminescent dosimetry experience with K2YF5 materials using beta and X-ray sources
    McLean, D
    Varas, J
    Khaidukov, N
    RADIATION PHYSICS AND CHEMISTRY, 2004, 71 (3-4) : 995 - 996
  • [18] THERMOLUMINESCENT INTERNAL BETA-RAY DOSIMETRY
    KASTNER, J
    HUKKOO, R
    OLTMAN, BG
    DAYAL, Y
    RADIATION RESEARCH, 1967, 32 (03) : 625 - &
  • [19] SOFT-X-RAY SOURCES
    GORENSTEIN, P
    TUCKER, WH
    ANNUAL REVIEW OF ASTRONOMY AND ASTROPHYSICS, 1976, 14 : 373 - 416
  • [20] SOFT-X-RAY DOSIMETRY - CALIBRATING THE SOFT-X-RAY CONTACT MICROSCOPY STATION
    GUTTMANN, GD
    HENKE, B
    HOWELLS, MR
    KERNER, JA
    MEDICAL PHYSICS, 1987, 14 (03) : 455 - 455