Semiconductor and thermoluminescent dosimetry of pulsed soft X ray plasma sources

被引:9
|
作者
Krása, J [1 ]
Cejnarová, A
Juha, L
Ryé, L
Scholz, M
Kubes, P
机构
[1] ASCR, Inst Phys, Dept Gas Lasers, Prague 18221 8, Czech Republic
[2] Inst Plasma Phys & Laser Microfus, PL-00908 Warsaw, Poland
[3] Czech Tech Univ, Prague 16627 6, Czech Republic
关键词
D O I
10.1093/oxfordjournals.rpd.a005906
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A multichannel detection system having a dynamic range of approximate to1 X 10(-9) Gy-20Gy was developed with the use of commercially produced Si-photodiodes and TLDs for accurate measurement of X ray energy emitted from plasma-focus facility and from laser-produced plasmas. The proof of linearity of the employed detectors accomplished by a comparison of their responses to a broad band spectrum of X rays emitted from plasmas, is reported. It is demonstrated that TLDs irradiated with no protective filter show an incorrect response due to overloading in the sub-keV range and repopulation of dosimetric peaks induced by the UV radiation. The measurement of the power of undesirable secondary X ray sources driven by the primary plasma inside the interaction chamber was performed on the basis of analysis of space dependence of X ray intensity with respect to the assumed r(-2) decrease in the intensity far away from the plasma.
引用
收藏
页码:429 / 432
页数:4
相关论文
共 50 条
  • [1] Semiconductor and thermoluminescent dosimetry of pulsed soft X ray plasma sources
    Krása, J
    Cejnarová, A
    Juha, L
    Ryc, L
    Scholz, M
    Kubes, P
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : 429 - 432
  • [2] Limitations of thermoluminescent dosimeters in soft X-ray diagnostics of pulsed plasma
    Krása, J
    Fárníková, M
    Juha, L
    Cejnarová, A
    NUKLEONIKA, 2001, 46 : S49 - S51
  • [3] HYDRATED ELECTRON AND THERMOLUMINESCENT DOSIMETRY OF PULSED X-RAY BEAMS
    FIELDEN, EM
    HART, EJ
    ADVANCES IN CHEMISTRY SERIES, 1968, (81): : 585 - &
  • [4] Absolute measurements of soft X-ray emission by laser plasma using thermoluminescent dosimeters and semiconductor detectors
    Farnikova, M
    Krasa, J
    Kralikova, B
    Skala, J
    Parys, P
    Ryc, L
    Wolowski, J
    Woryna, E
    FOURTH INTERNATIONAL WORKSHOP ON IODINE LASERS AND APPLICATIONS, 1996, 2767 : 113 - 118
  • [5] Thermoluminescent dosimetry of x-ray radiation emitted from a laser-produced plasma
    Farnikova, M
    Krasa, J
    Juha, L
    Ryc, L
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1996, 29 (08) : 2119 - 2123
  • [6] THERMOLUMINESCENT X-RAY DOSIMETRY OF LASER FUSION PLASMAS
    CHARATIS, G
    SEGALL, SB
    MAYER, FJ
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1976, 21 (09): : 1084 - 1084
  • [7] SOME SOURCES OF ERROR IN THERMOLUMINESCENT DOSIMETRY
    MUSILEK, L
    DARICKOVA, A
    KERNENERGIE, 1988, 31 (07): : 322 - 325
  • [8] THERMOLUMINESCENT RADIATION DOSIMETRY APPLIED TO DENTAL X-RAY EXPOSURES
    HOWLEY, JR
    ROBBINS, C
    DICKINSO.MB
    HEALTH PHYSICS, 1968, 15 (02): : 181 - +
  • [9] Application of Thermoluminescent Detectors for Pulsed X-Ray Spectrometry
    Busygina, I. A.
    Grigoryeva, I. G.
    Moskvich, P. V.
    Naumov, P. Yu.
    Salakhutdinov, G. Kh.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2024, 67 (01) : 108 - 112
  • [10] REPETITIVELY PULSED-PLASMA SOFT-X-RAY SOURCE
    NAGEL, DJ
    BROWN, CM
    PECKERAR, MC
    GINTER, ML
    ROBINSON, JA
    MCILRATH, TJ
    CARROLL, PK