An on-line, fast, simple, selective, and sensitive method has been developed for the determination of three herbicides belonging to the following families: triazines (atrazine), chloroacetamide (alachlor), and phenoxy (2,4-dichlorophenoxyacetic acid) in water samples. The method involves an in-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction along with simultaneous silylation prior to their determination by gas chromatography with mass spectrometry. Extraction, derivatization, and preconcentration have been simultaneously performed using acetone as dispersive solvent, N-methyl-N-tert-butyldimethylsilyltrifluoroacetamide as derivatization agent and trichloroethylene as extraction solvent. After stirring for 180 s, the sedimented phase was transferred to a rotary micro-volume injection valve (3 mu L) and introduced by an air stream into gas chromatograph with mass spectrometry detector. Recovery and enrichment factors were 87.2-111.2% and 7.4-10.4, respectively. Relative standard deviations were in the ranges of 6.6-7.4 for intraday and 9.2-9.6 for interday precision. The detection limits were in the range of 0.045-0.03 mu g/L, and good linearity was observed up to 200 mu g/L, with R-2 ranging between 0.9905 and 0.9964. The developed method was satisfactorily applied to assess the occurrence of the studied herbicides in groundwater samples. The recovery test was also performed with values between 77 and 117%.
引用
收藏
页码:1096 / 1103
页数:8
相关论文
共 50 条
  • [1] In-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction and silylation prior gas chromatography-mass spectrometry for ultraviolet filters determination in environmental water samples
    Clavijo, Sabrina
    Avivar, Jessica
    Suarez, Ruth
    Cerda, Victor
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2016, 1443 : 26 - 34
  • [2] In-syringe-stirring: A novel approach for magnetic stirring-assisted dispersive liquid-liquid microextraction
    Horstkotte, Burkhard
    Suarez, Ruth
    Solich, Petr
    Cerda, Victor
    [J]. ANALYTICA CHIMICA ACTA, 2013, 788 : 52 - 60
  • [3] Magnetic stirring-assisted dispersive liquid-liquid microextraction followed by high performance liquid chromatography for determination of phthalate esters in drinking and environmental water samples
    Ranjbari, Elias
    Hadjmohammadi, Mohammad Reza
    [J]. TALANTA, 2012, 100 : 447 - 453
  • [4] In-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction for automation and downscaling of methylene blue active substances assay
    Suarez, Ruth
    Horstkotte, Burkhard
    Cerda, Victor
    [J]. TALANTA, 2014, 130 : 555 - 560
  • [5] A new device for magnetic stirring-assisted dispersive liquid-liquid microextraction of UV filters in environmental water samples
    Zhang, Ping-Ping
    Shi, Zhi-Guo
    Yu, Qiong-Wei
    Feng, Yu-Qi
    [J]. TALANTA, 2011, 83 (05) : 1711 - 1715
  • [6] Simultaneous determination of nine dinitroaniline herbicides in environmental samples using a validated vortex-assisted dispersive liquid-liquid microextraction procedure coupled with GC-MS/MS
    Abdallah, Osama Ibrahim
    [J]. CHEMICAL PAPERS, 2020, 74 (07): : 2311 - 2326
  • [7] Fully-automated magnetic stirring-assisted lab-in-syringe dispersive liquid-liquid microextraction for the determination of arsenic species in rice samples
    Wang, Xiaojun
    Xu, Guoliang
    Chen, Peng
    Sun, Yueshu
    Yao, Xiaoting
    Lv, Yan
    Guo, Weiwei
    Wang, Guozhen
    [J]. RSC ADVANCES, 2018, 8 (30) : 16858 - 16865
  • [8] Estrogens determination in wastewater samples by automatic in-syringe dispersive liquid-liquid microextraction prior silylation and gas chromatography
    Gonzalez, Alba
    Avivar, Jessica
    Cerda, Victor
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2015, 1413 : 1 - 8
  • [9] Determination of perfluoroalkyl carboxylic acids in environmental water samples by dispersive liquid-liquid microextraction with GC-MS analysis
    Hu, Zhixiong
    Li, Qian
    Xu, Li
    Zhang, Weinong
    Zhang, Yanpeng
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2020, 43 (7-8) : 282 - 290
  • [10] Ultrasound-assisted dispersive liquid-liquid microextraction followed by GC-MS/MS analysis for the determination of valproic acid in urine samples
    Jain, Rajeev
    Gupta, Manoj Kumar
    Chauhan, Abhishek
    Pandey, Vivek
    Mudiam, Mohana Krishna Reddy
    [J]. Bioanalysis, 2015, 7 (19) : 2451 - 2459