Determination of herbicides in environmental water samples by simultaneous in-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction and silylation followed by GC-MS

被引:26
|
作者
Suarez, Ruth [1 ]
Clavijo, Sabrina [2 ]
Gonzalez, Alba [2 ]
Cerda, Victor [1 ,2 ]
机构
[1] Univ Balearic Isl, Grp Analyt Chem Automat & Environm, Palma De Mallorca, Spain
[2] Univ Balearic Isl, Sciware Syst SL, Bunyola, Spain
关键词
aqueous silylation; dispersive liquid-liquid microextraction; groundwater; herbicides; SOLID-PHASE EXTRACTION; CHROMATOGRAPHY-MASS SPECTROMETRY; GAS-CHROMATOGRAPHY; AQUEOUS SAMPLES; TRIAZINE HERBICIDES; RAPID-DETERMINATION; ACID HERBICIDES; ATRAZINE; PESTICIDES; ALACHLOR;
D O I
10.1002/jssc.201700875
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An on-line, fast, simple, selective, and sensitive method has been developed for the determination of three herbicides belonging to the following families: triazines (atrazine), chloroacetamide (alachlor), and phenoxy (2,4-dichlorophenoxyacetic acid) in water samples. The method involves an in-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction along with simultaneous silylation prior to their determination by gas chromatography with mass spectrometry. Extraction, derivatization, and preconcentration have been simultaneously performed using acetone as dispersive solvent, N-methyl-N-tert-butyldimethylsilyltrifluoroacetamide as derivatization agent and trichloroethylene as extraction solvent. After stirring for 180 s, the sedimented phase was transferred to a rotary micro-volume injection valve (3 mu L) and introduced by an air stream into gas chromatograph with mass spectrometry detector. Recovery and enrichment factors were 87.2-111.2% and 7.4-10.4, respectively. Relative standard deviations were in the ranges of 6.6-7.4 for intraday and 9.2-9.6 for interday precision. The detection limits were in the range of 0.045-0.03 mu g/L, and good linearity was observed up to 200 mu g/L, with R-2 ranging between 0.9905 and 0.9964. The developed method was satisfactorily applied to assess the occurrence of the studied herbicides in groundwater samples. The recovery test was also performed with values between 77 and 117%.
引用
收藏
页码:1096 / 1103
页数:8
相关论文
共 50 条
  • [21] Multivariate optimization of dispersive liquid-liquid microextraction for the determination of paclobutrazol and triflumizole in water by GC-MS
    Chormey, Dotse Selali
    Karakus, Yesim
    Karayaka, Sena
    Ozsoyler, Cagla
    Bozdogan, Abdurrezzak Emin
    Bakirdere, Sezgin
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (23) : 4541 - 4548
  • [22] Dispersive liquid-liquid microextraction for the determination of menthol residue in fish by GC-MS
    Coelho Botrel, Bianca Mesquita
    Pereira Abreu, Daiane Cassia
    Saczk, Adelir Aparecida
    Ferreira Bazana, Matheus Julien
    Nascimento, Carina de Fatima
    Vieira e Rosa, Priscila
    MICROCHEMICAL JOURNAL, 2017, 133 : 70 - 75
  • [23] Application of dispersive liquid-liquid microextraction followed by HPLC-MS/MS for the trace determination of clotrimazole in environmental water samples
    Zgola-Grzeskowiak, Agnieszka
    Grzeskowiak, Tomasz
    JOURNAL OF SEPARATION SCIENCE, 2013, 36 (15) : 2514 - 2521
  • [24] In-syringe magnetic-stirring-assisted liquid–liquid microextraction for the spectrophotometric determination of Cr(VI) in waters
    Camelia Henríquez
    Burkhard Horstkotte
    Petr Solich
    Víctor Cerdà
    Analytical and Bioanalytical Chemistry, 2013, 405 : 6761 - 6769
  • [25] Comparison of two novel in-syringe dispersive liquid-liquid microextraction techniques for the determination of iodide in water samples using spectrophotometry
    Kaykhaii, Massoud
    Sargazi, Mona
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2014, 121 : 173 - 179
  • [26] In-syringe demulsified dispersive liquid-liquid microextraction and high performance liquid chromatography-mass spectrometry for the determination of trace fungicides in environmental water samples
    Xia, Yating
    Cheng, Min
    Guo, Feng
    Wang, Xiangfang
    Cheng, Jing
    ANALYTICA CHIMICA ACTA, 2012, 724 : 47 - 53
  • [27] Simultaneous determination of nine dinitroaniline herbicides in environmental samples using a validated vortex-assisted dispersive liquid–liquid microextraction procedure coupled with GC–MS/MS
    Osama Ibrahim Abdallah
    Chemical Papers, 2020, 74 : 2311 - 2326
  • [28] Application of dispersive liquid-liquid microextraction and GC-MS/MS for the determination of GHB in beverages and hair
    Meng, Liang
    Chen, Sihai
    Zhu, Binling
    Zhang, Jun
    Mei, Yue
    Cao
    Zheng, Kefang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2020, 1144 (1144):
  • [29] Vortex-assisted extraction in tandem with dispersive liquid-liquid microextraction followed by GC-MS for determination of Achillea wilhelmsii essential oil
    Sereshti, Hassan
    Ghiasi, Abdollah
    Naderloo, Mandi
    Taghizadeh, Massoud
    Astaneh, Shakiba Darvish Alipoar
    ANALYTICAL METHODS, 2014, 6 (17) : 6695 - 6701
  • [30] Magnetic stirring-assisted dispersive liquid-liquid microextraction in narrow neck glass tube for determination of cadmium in water, fruit and vegetable samples using response surface methodology
    Mohammadzadeh, Ali
    Ramezani, Majid
    Niazi, Ali
    DESALINATION AND WATER TREATMENT, 2016, 57 (21) : 9745 - 9755