Fully-automated magnetic stirring-assisted lab-in-syringe dispersive liquid-liquid microextraction for the determination of arsenic species in rice samples

被引:19
|
作者
Wang, Xiaojun [1 ]
Xu, Guoliang [1 ]
Chen, Peng [1 ]
Sun, Yueshu [1 ]
Yao, Xiaoting [1 ]
Lv, Yan [1 ]
Guo, Weiwei [1 ]
Wang, Guozhen [1 ]
机构
[1] Zhejiang Univ Water Resources & Elect Power, Coll Civil Engn & Architecture, 583 Xuelin St, Hangzhou 310018, Zhejiang, Peoples R China
关键词
ATOMIC-ABSORPTION-SPECTROMETRY; SOLID-PHASE EXTRACTION; ENVIRONMENTAL WATER SAMPLES; HPLC-ICP-MS; HYDRIDE GENERATION; SPECIATION; INJECTION; SELENIUM;
D O I
10.1039/c8ra00875b
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Fully-automated magnetic stirring-assisted lab-in-syringe dispersive liquid-liquid microextraction (MAS-LIS-DLLME), combined with graphite furnace atomic absorption spectrometry (GFAAS) was developed for the fast and efficient separation and preconcentration of trace levels of inorganic arsenic species in rice samples. This totally automated analytical procedure combines the advantages of lab-in-syringe flow system and dispersive liquid-liquid microextraction (DLLME) aiming at separation of trace arsenite and arsenate species from natural matrix for the first time. With a single syringe pump that is coupled with a multiposition valve, the whole lab-in-syringe microextraction process including cleaning, mixing, microextraction, phase separation, and target analyte collection was implemented in a fully-automated way. Significant factors of the MAS-LIS-DLLME method were sample acidity, concentration of the chelating agent, amounts of ionic liquids (ILs), aspiration speed and matrix interference. Using the present method, the limits of detection (LODs) for As(V) was 0.005 mu g L-1. The relative standard deviation (RSDs) for seven replicate measurements of 2.0 mu g L-1 of As(V) was 3.7%. The linear dynamic range (LDR) was 0.04-5.0 mu g L-1 and the determination coefficients was 0.9990. Under the optimum conditions, the developed totally automated analytical procedure was successfully applied for the trace arsenite and arsenate species studies in natural rice samples and standard reference materials with satisfactory results.
引用
收藏
页码:16858 / 16865
页数:8
相关论文
共 50 条
  • [1] In-syringe-stirring: A novel approach for magnetic stirring-assisted dispersive liquid-liquid microextraction
    Horstkotte, Burkhard
    Suarez, Ruth
    Solich, Petr
    Cerda, Victor
    [J]. ANALYTICA CHIMICA ACTA, 2013, 788 : 52 - 60
  • [2] Fully-automated in-syringe dispersive liquid-liquid microextraction for the determination of caffeine in coffee beverages
    Frizzarin, Rejane M.
    Maya, Fernando
    Estela, Jose M.
    Cerda, Victor
    [J]. FOOD CHEMISTRY, 2016, 212 : 759 - 767
  • [3] An automatic stirring-assisted liquid-liquid microextraction system based on lab-in-syringe platform for on-line atomic spectrometric determination of trace metals
    Giakisikli, Georgia
    Anthemidis, Aristidis N.
    [J]. TALANTA, 2017, 166 : 364 - 368
  • [4] Determination of herbicides in environmental water samples by simultaneous in-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction and silylation followed by GC-MS
    Suarez, Ruth
    Clavijo, Sabrina
    Gonzalez, Alba
    Cerda, Victor
    [J]. JOURNAL OF SEPARATION SCIENCE, 2018, 41 (05) : 1096 - 1103
  • [5] A new device for magnetic stirring-assisted dispersive liquid-liquid microextraction of UV filters in environmental water samples
    Zhang, Ping-Ping
    Shi, Zhi-Guo
    Yu, Qiong-Wei
    Feng, Yu-Qi
    [J]. TALANTA, 2011, 83 (05) : 1711 - 1715
  • [6] Lab in a syringe: fully automated dispersive liquid-liquid microextraction with integrated spectrophotometric detection
    Maya, Fernando
    Horstkotte, Burkhard
    Manuel Estela, Jose
    Cerda, Victor
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 404 (03) : 909 - 917
  • [7] Fully-Automated Fluorimetric Determination of Aluminum in Seawater by In-Syringe Dispersive Liquid-Liquid Microextraction Using Lumogallion
    Suarez, Ruth
    Horstkotte, Burkhard
    Duarte, Carlos M.
    Cerda, Victor
    [J]. ANALYTICAL CHEMISTRY, 2012, 84 (21) : 9462 - 9469
  • [8] In-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction for automation and downscaling of methylene blue active substances assay
    Suarez, Ruth
    Horstkotte, Burkhard
    Cerda, Victor
    [J]. TALANTA, 2014, 130 : 555 - 560
  • [9] Magnetic stirring-assisted dispersive liquid-liquid microextraction followed by high performance liquid chromatography for determination of phthalate esters in drinking and environmental water samples
    Ranjbari, Elias
    Hadjmohammadi, Mohammad Reza
    [J]. TALANTA, 2012, 100 : 447 - 453
  • [10] In-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction and silylation prior gas chromatography-mass spectrometry for ultraviolet filters determination in environmental water samples
    Clavijo, Sabrina
    Avivar, Jessica
    Suarez, Ruth
    Cerda, Victor
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2016, 1443 : 26 - 34