In-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction for automation and downscaling of methylene blue active substances assay

被引:27
|
作者
Suarez, Ruth [1 ]
Horstkotte, Burkhard [2 ]
Cerda, Victor [1 ]
机构
[1] Univ Balearic Isl, Lab Environm Analyt Chem LQA2, Palma de Mallorca 07122, Spain
[2] Charles Univ Prague, Fac Pharm, Dept Analyt Chem, CZ-50005 Hradec Kralove, Czech Republic
关键词
In-syringe magnetic-stirring-assisted; dispersive liquid-liquid microextraction; Anionic surfactants; Methylene blue active substances assay; Sequential injection analysis; ANIONIC SURFACTANTS; SOLVENT-EXTRACTION; SPECTROPHOTOMETRIC DETERMINATION; INJECTION-ANALYSIS; CHROMATOGRAPHY; WATER; PRECONCENTRATION; LIGHTER; SYSTEM;
D O I
10.1016/j.talanta.2014.06.063
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and rapid method for the determination of the methylene blue active substances assay based on in-syringe automation of magnetic stirring-assisted dispersive liquid-liquid microextraction was developed. The proposed method proved to be valid for the determination of anionic surfactant in waste, pond, well, tap, and drinking water samples. Sample mixing with reagents, extraction and phase separation were performed within the syringe of an automated syringe pump containing a magnetic stirring bar for homogenization and solvent dispersion. The syringe module was used upside-down to enable the use of chloroform as an extraction solvent of higher density than water. The calibration was found to be linear up to 0.3 mg/L using only 200 mu L of solvent and 4 mL of sample. The limits of detection (3 sigma) and quantification (10 sigma) were 7.0 mu g/L and 22 mu g/L, respectively. The relative standard deviation for 10 replicate determinations of 0.1 mg/L SBDS was below 3%. Concentrations of anionic surfactants in natural water samples were in the range of 0.032-0.213 mg/L and no significant differences towards the standard method were found. Standard additions gave analyte recoveries between 95% and 106% proving the general applicability and adequateness of the system to MBSA index determination. Compared to the tedious standard method requiring up to 50 mL of chloroform, the entire procedure took only 345 s using 250-times less solvent. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:555 / 560
页数:6
相关论文
共 50 条
  • [1] In-syringe-stirring: A novel approach for magnetic stirring-assisted dispersive liquid-liquid microextraction
    Horstkotte, Burkhard
    Suarez, Ruth
    Solich, Petr
    Cerda, Victor
    [J]. ANALYTICA CHIMICA ACTA, 2013, 788 : 52 - 60
  • [2] In-syringe dispersive liquid-liquid microextraction
    Lemos, Valfredo Azevedo
    Barreto, Jeferson Alves
    Santos, Luana Bastos
    de Assis, Rosivan dos Santos
    Novaes, Cleber Galvao
    Cassella, Ricardo J.
    [J]. TALANTA, 2022, 238
  • [3] Automated in-syringe dispersive liquid-liquid microextraction
    Maya, Fernando
    Horstkotte, Burkhard
    Estela, Jose M.
    Cerda, Victor
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2014, 59 : 1 - 8
  • [4] Determination of herbicides in environmental water samples by simultaneous in-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction and silylation followed by GC-MS
    Suarez, Ruth
    Clavijo, Sabrina
    Gonzalez, Alba
    Cerda, Victor
    [J]. JOURNAL OF SEPARATION SCIENCE, 2018, 41 (05) : 1096 - 1103
  • [5] In-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction and silylation prior gas chromatography-mass spectrometry for ultraviolet filters determination in environmental water samples
    Clavijo, Sabrina
    Avivar, Jessica
    Suarez, Ruth
    Cerda, Victor
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2016, 1443 : 26 - 34
  • [6] In-syringe magnetic-stirring-assisted liquid-liquid microextraction for the spectrophotometric determination of Cr(VI) in waters
    Henriquez, Camelia
    Horstkotte, Burkhard
    Solich, Petr
    Cerda, Victor
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (21) : 6761 - 6769
  • [7] Fully-automated magnetic stirring-assisted lab-in-syringe dispersive liquid-liquid microextraction for the determination of arsenic species in rice samples
    Wang, Xiaojun
    Xu, Guoliang
    Chen, Peng
    Sun, Yueshu
    Yao, Xiaoting
    Lv, Yan
    Guo, Weiwei
    Wang, Guozhen
    [J]. RSC ADVANCES, 2018, 8 (30) : 16858 - 16865
  • [8] A new device for magnetic stirring-assisted dispersive liquid-liquid microextraction of UV filters in environmental water samples
    Zhang, Ping-Ping
    Shi, Zhi-Guo
    Yu, Qiong-Wei
    Feng, Yu-Qi
    [J]. TALANTA, 2011, 83 (05) : 1711 - 1715
  • [9] In-syringe magnetic-stirring-assisted liquid–liquid microextraction for the spectrophotometric determination of Cr(VI) in waters
    Camelia Henríquez
    Burkhard Horstkotte
    Petr Solich
    Víctor Cerdà
    [J]. Analytical and Bioanalytical Chemistry, 2013, 405 : 6761 - 6769
  • [10] One-step in-syringe ionic liquid-based dispersive liquid-liquid microextraction
    Cruz-Vera, Marta
    Lucena, Rafael
    Cardenas, Soledad
    Valcarcel, Miguel
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (37) : 6459 - 6465