The PTB water calorimeter for the absolute determination of absorbed dose to water in 60Co radiation

被引:64
|
作者
Krauss, A [1 ]
机构
[1] Phys Tech Bundesanstalt, D-3300 Braunschweig, Germany
关键词
D O I
10.1088/0026-1394/43/3/008
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The quantity to be measured in dosimetry for radiation therapy is the absorbed dose to water, D-w. At the Physikalisch-Technische Bundesanstalt a water calorimeter is established as the primary standard for D-w in Co-60 radiation under reference conditions. The water calorimeter is capable of measuring the absorbed dose to water with a combined standard uncertainty of 0.20%. Some aspects of the design and operation of the water calorimeter are discussed. Detailed experimental and theoretical investigations for the different influence quantities affecting the calorimetric results are presented.
引用
收藏
页码:259 / 272
页数:14
相关论文
共 50 条
  • [1] Absolute measurement of absorbed dose to water for γ-ray of 60Co by water calorimetry
    Yang, Qian
    Fan, Jie
    Xu, Shimeng
    [J]. He Jishu/Nuclear Techniques, 2024, 47 (07):
  • [2] The PTB water calorimeter for determining the absolute absorbed dose to water in ultra-high pulse dose rate electron beams
    Bourgouin, Alexandra
    Hackel, Thomas
    Kapsch, Ralf-Peter
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (11):
  • [3] Comparison of the standards for absorbed dose to water of the NRC and the BIPM for 60Co gamma radiation
    Kessler, C.
    Burns, D. T.
    Allisy-Roberts, P. J.
    McCaffrey, J. P.
    McEwen, M. R.
    Ross, C. K.
    [J]. METROLOGIA, 2010, 47
  • [4] Comparison of the standards for absorbed dose to water of the ARPANSA and the BIPM for 60Co gamma radiation
    Kessler, C.
    Burns, D. T.
    Allisy-Roberts, P. J.
    Butler, D.
    Lye, J.
    Webb, D.
    [J]. METROLOGIA, 2012, 49
  • [5] Comparison of the standards for absorbed dose to water of the BEV, Austria, and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    Steurer, A.
    Tiefenboeck, W.
    Gabris, F.
    [J]. METROLOGIA, 2010, 47
  • [6] CCRI supplementary comparison of standards for absorbed dose to water in 60Co gamma radiation at radiation processing dose levels
    Burns, D. T.
    Allisy-Roberts, P. J.
    Desrosiers, M. F.
    Nagy, V. Yu.
    Sharpe, P. H. G.
    Laitano, R. F.
    Mehta, K.
    Schneider, M. K. H.
    Zhang, Y. L.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2006, 75 (09) : 1087 - 1092
  • [7] A standard for absorbed dose rate to water in a 60Co field using a graphite calorimeter at the National Metrology Institute of Japan
    Morishita, Y.
    Kato, M.
    Takata, N.
    Kurosawa, T.
    Tanaka, T.
    Saito, N.
    [J]. RADIATION PROTECTION DOSIMETRY, 2013, 154 (03) : 331 - 339
  • [8] An absorbed dose to water calorimeter for collimated radiation fields
    Brede, HJ
    Hecker, O
    Hollnagel, R
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 455 (03): : 721 - 732
  • [9] A comparison of Australian and Canadian calibration coefficients for air kerma and absorbed dose to water for 60Co γ radiation
    Shortt K.R.
    Huntley R.B.
    Kotler L.H.
    Boas J.F.
    Webb D.V.
    [J]. Australasian Physics & Engineering Sciences in Medicine, 2006, 29 (2): : 206 - 215
  • [10] ABSORBED DOSE WATER CALORIMETER
    DOMEN, SR
    [J]. MEDICAL PHYSICS, 1980, 7 (02) : 157 - 159