Taking the perfect nuclear image: Quality control, acquisition, and processing techniques for cardiac SPECT, PET, and hybrid imaging

被引:21
|
作者
Case, James A. [1 ,2 ,3 ]
Bateman, Timothy M. [1 ,2 ,3 ]
机构
[1] St Lukes Mid Amer Heart Inst, Kansas City, MO USA
[2] Univ Missouri, Kansas City, MO 64110 USA
[3] Cardiovasc Imaging Technol, Kansas City, MO USA
关键词
Image artifacts; image processing; image reconstruction; PET imaging; SPECT; MYOCARDIAL-PERFUSION SPECT; POSITRON-EMISSION-TOMOGRAPHY; CORONARY-ARTERY-DISEASE; ATTENUATION CORRECTION; PATIENT MOTION; DIAGNOSTIC-ACCURACY; SESTAMIBI SPECT; FLOW RESERVE; SIMULTANEOUS TRANSMISSION; QUANTITATIVE ASSESSMENT;
D O I
10.1007/s12350-013-9760-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Nuclear Cardiology for the past 40 years has distinguished itself in its ability to non-invasively assess regional myocardial blood flow and identify obstructive coronary disease. This has led to advances in managing the diagnosis, risk stratification, and prognostic assessment of cardiac patients. These advances have all been predicated on the collection of high quality nuclear image data. National and international professional societies have established guidelines for nuclear laboratories to maintain high quality nuclear cardiology services. In addition, laboratory accreditation has further advanced the goal of the establishing high quality standards for the provision of nuclear cardiology services. This article summarizes the principles of nuclear cardiology single photon emission computed tomography (SPECT) and positron emission tomography (PET) imaging and techniques for maintaining quality: from the calibration of imaging equipment to post processing techniques. It also will explore the quality considerations of newer technologies such as cadmium zinc telleride (CZT)-based SPECT systems and absolute blood flow measurement techniques using PET.
引用
收藏
页码:891 / 907
页数:17
相关论文
共 50 条
  • [41] Early Detection Method of Enterococci for Water Quality Control with Digital Image Processing Techniques
    Morales, Laura Victoria Vigoya
    Dolores Valdes, Maria
    Trillo, Cristina
    [J]. 2016 XXI SYMPOSIUM ON SIGNAL PROCESSING, IMAGES AND ARTIFICIAL VISION (STSIVA), 2016,
  • [42] Imaging techniques and methodologies for acquisition, processing and distribution of multimodal image data from the oeuvre of Jan van Eyck
    Fransen, Bart
    Temmermans, Frederik
    Currie, Christina
    [J]. OPTICS, PHOTONICS AND DIGITAL TECHNOLOGIES FOR IMAGING APPLICATIONS VI, 2021, 11353
  • [43] SPECT imaging in the diagnosis of pulmonary embolism: Automated detection of match and mismatch defects by means of image-processing techniques
    Reinartz, P
    Kaiser, HJ
    Wildberger, JE
    Gordji, C
    Nowak, B
    Buell, U
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2006, 47 (06) : 968 - 973
  • [44] Image Quality Performance of a Dedicated Cardiac Discovery NM 530c SPECT: Impact of Time Acquisition and Reconstruction Parameters
    Favero, Mariana Saibt
    Marques da Silva, Ana Maria
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 3, 2019, 68 (03): : 703 - 707
  • [45] Quality Control of PET/MRI systems: Consensus Recommendations from a European Network of Hybrid Imaging Sites (HYBRID)
    Valladares, A.
    Ahangari, S.
    Beyer, T.
    Boellaard, R.
    Chalampalakis, Z.
    Comtat, C.
    DalToso, L.
    Hansen, A. E.
    Koole, M.
    Mackewn, J.
    Marsden, P.
    Nuyts, J.
    Poth, S.
    Solari, E.
    Rausch, I.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S207 - S208
  • [46] Advances in cardiac imaging: Taking a closer look at PET perfusion imaging American Society of Nuclear Cardiology, Philadelphia, PA, 24 September 2010
    Branscomb, Elizabeth
    Heller, Gary
    Bateman, Timothy
    Soman, Prem
    Bateman, Timothy
    Branscomb, Elizabeth
    Maddahi, Jamshid
    Branscomb, Elizabeth
    Garcia, Ernest
    Soman, Prem
    Garcia, Ernest
    Berman, Daniel
    DePuey, Gordon
    Garcia, Ernest
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2012, 19 : S46 - S47
  • [47] The hybrid imaging techniques- SPECT-CT and PET-CT in the diagnostic algorithm in patients with somatostatin expressing tumors
    Kostadinova, I.
    Stoinova, V.
    Grudeva, V.
    Demirev, A.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S651 - S651
  • [48] Nuclear imaging drug development tools - PET and SPECT help enhance the quality of a product and prevent late-stage failure
    Buchanan, Lynn
    Jurek, Paul
    Redshaw, Russ
    [J]. GENETIC ENGINEERING & BIOTECHNOLOGY NEWS, 2007, 27 (08): : 23 - +
  • [49] Evaluation of optimal acquisition time and image quality for half-dose 201Tl SPECT-MPI using cardiac dedicated ultrafast SPECT camera
    Kimoto, R.
    Nagahiro, K.
    Tanaka, M.
    Ogushi, G.
    Tomiguchi, S.
    Katsda, N.
    Shiraishi, S.
    Yamashita, Y.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S653 - S654
  • [50] Advanced signal processing techniques for THz imaging and sensing enhancement in material quality control applications
    Stock, Daniel
    Kahl, Matthias
    Wigger, Anna K.
    Wong, Tak Ming
    Kolb, Andreas
    Bolivar, Peter Haring