Taking the perfect nuclear image: Quality control, acquisition, and processing techniques for cardiac SPECT, PET, and hybrid imaging

被引:21
|
作者
Case, James A. [1 ,2 ,3 ]
Bateman, Timothy M. [1 ,2 ,3 ]
机构
[1] St Lukes Mid Amer Heart Inst, Kansas City, MO USA
[2] Univ Missouri, Kansas City, MO 64110 USA
[3] Cardiovasc Imaging Technol, Kansas City, MO USA
关键词
Image artifacts; image processing; image reconstruction; PET imaging; SPECT; MYOCARDIAL-PERFUSION SPECT; POSITRON-EMISSION-TOMOGRAPHY; CORONARY-ARTERY-DISEASE; ATTENUATION CORRECTION; PATIENT MOTION; DIAGNOSTIC-ACCURACY; SESTAMIBI SPECT; FLOW RESERVE; SIMULTANEOUS TRANSMISSION; QUANTITATIVE ASSESSMENT;
D O I
10.1007/s12350-013-9760-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Nuclear Cardiology for the past 40 years has distinguished itself in its ability to non-invasively assess regional myocardial blood flow and identify obstructive coronary disease. This has led to advances in managing the diagnosis, risk stratification, and prognostic assessment of cardiac patients. These advances have all been predicated on the collection of high quality nuclear image data. National and international professional societies have established guidelines for nuclear laboratories to maintain high quality nuclear cardiology services. In addition, laboratory accreditation has further advanced the goal of the establishing high quality standards for the provision of nuclear cardiology services. This article summarizes the principles of nuclear cardiology single photon emission computed tomography (SPECT) and positron emission tomography (PET) imaging and techniques for maintaining quality: from the calibration of imaging equipment to post processing techniques. It also will explore the quality considerations of newer technologies such as cadmium zinc telleride (CZT)-based SPECT systems and absolute blood flow measurement techniques using PET.
引用
收藏
页码:891 / 907
页数:17
相关论文
共 50 条
  • [21] Towards consensus in acquisition and image analysis of PET and SPECT in the assessment of cardiac sympathetic innervation: a mini-review
    Walter Noordzij
    Andor W. J. M. Glaudemans
    Luis E. Juarez-Orozco
    Riemer H. J. A. Slart
    [J]. Clinical and Translational Imaging, 2019, 7 : 33 - 38
  • [22] Towards consensus in acquisition and image analysis of PET and SPECT in the assessment of cardiac sympathetic innervation: a mini-review
    Noordzij, Walter
    Glaudemans, Andor W. J. M.
    Juarez-Orozco, Luis E.
    Slart, Riemer H. J. A.
    [J]. CLINICAL AND TRANSLATIONAL IMAGING, 2019, 7 (01) : 33 - 38
  • [23] Image Quality Assessment for Low-Dose-CT in Hybrid SPECT/CT Imaging
    Grosser, Oliver S.
    Ruf, Juri
    Kupitz, Dennis
    Czuczwara, Damian
    Loewenthal, David
    Thormann, Markus
    Furth, Christian
    Ricke, Jens
    Pech, Maciej
    Kreissl, Michael C.
    Amthauer, Holger
    [J]. NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2018, 57 (04): : 153 - 159
  • [24] Medical Image Processing Server applied to Quality Control of Nuclear Medicine
    Vergara, C.
    Graffigna, J. P.
    Marino, E.
    Omati, S.
    Holleywell, P.
    [J]. 20TH ARGENTINEAN BIOENGINEERING SOCIETY CONGRESS (XX ARGENTINE BIOENGINEERING CONGRESS AND IX CONFERENCE OF CLINICAL ENGINEERING), (SABI 2015), 2016, 705
  • [25] Image quality as a function of acquisition protocol for whole-body PET oncology imaging.
    Kinahan, PE
    Meltzer, CC
    McCook, B
    Chandler, S
    Lartizien, C
    Swensson, R
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 201P - 201P
  • [26] Image quality evaluation of a new acquisition orbit (cardiac-centered circular orbit) in myocardial perfusion SPECT
    Ichikawa, Hajime
    Kato, Toyohiro
    Kondo, Hiroki
    Shibutani, Takayuki
    Shimada, Hideki
    Onoguchi, Masahisa
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [27] Hybrid imaging in Crohn's disease: from SPECT/CT to PET/MR and new image interpretation criteria
    Catalano, Onofrio
    Macioni, Francesca
    Lauri, Chiara
    Auletta, Sveva
    Dierckx, Rudi
    Signore, Alberto
    [J]. QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 62 (01): : 40 - 55
  • [28] Impact of Point-Spread Function Modeling on PET Image Quality in Integrated PET/MR Hybrid Imaging
    Aklan, Bassim
    Oehmigen, Mark
    Beiderwellen, Karsten
    Ruhlmann, Marcus
    Paulus, Daniel H.
    Jakoby, Bjoern W.
    Ritt, Philipp
    Quick, Harald H.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (01) : 78 - 84
  • [29] Hybrid cardiac imaging: SPECT/CT and PET/CT. A joint position statement by the European Association of Nuclear Medicine (EANM), the European Society of Cardiac Radiology (ESCR) and the European Council of Nuclear Cardiology (ECNC)
    Flotats, Albert
    Knuuti, Juhani
    Gutberlet, Matthias
    Marcassa, Claudio
    Bengel, Frank M.
    Kaufmann, Philippe A.
    Rees, Michael R.
    Hesse, Birger
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (01) : 201 - 212
  • [30] Hybrid cardiac imaging: SPECT/CT and PET/CT. A joint position statement by the European Association of Nuclear Medicine (EANM), the European Society of Cardiac Radiology (ESCR) and the European Council of Nuclear Cardiology (ECNC)
    Albert Flotats
    Juhani Knuuti
    Matthias Gutberlet
    Claudio Marcassa
    Frank M. Bengel
    Philippe A. Kaufmann
    Michael R. Rees
    Birger Hesse
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2011, 38 : 201 - 212