Image Quality Performance of a Dedicated Cardiac Discovery NM 530c SPECT: Impact of Time Acquisition and Reconstruction Parameters

被引:0
|
作者
Favero, Mariana Saibt [1 ]
Marques da Silva, Ana Maria [2 ]
机构
[1] Nucleorad, Porto Alegre, RS, Brazil
[2] Pontificia Univ Catolica Rio Grande do Sul, Sci Sch, Lab Med Imaging, Porto Alegre, RS, Brazil
关键词
SPECT; Cardiology; CZT; Image quality; Discovery NM 530c; MYOCARDIAL-PERFUSION SPECT; SIGNIFICANT REDUCTION; CZT CAMERA; PHANTOM; SYSTEM;
D O I
10.1007/978-981-10-9023-3_128
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this study is to evaluate the impact of acquisition time and reconstruction parameters in image quality in a dedicated cardiac Discovery NM 530c CZT SPECT scanner. Anthropomorphic torso phantom with a cardiac insert and a cold lesion starting with 84 kBq/ml, 62 kBq/ml and 3 kBq/ml in myocardium, liver and background, respectively, simulated high-dose stress Tc-99m acquisition. During two half-lives, images were acquired hourly to simulate lower doses, using both 3 and 5 min time acquisition. Reconstruction parameters were used separately per type of acquisition (low-dose and high-dose), according to manufacturer recommendation. Image quality and cold lesion visibility were evaluated using normalized standard deviation (NSD), ventricle-wall cavity contrast (VCC), contrast-to-noise ratio (CNR), and lesion effective contrast (EC). Variations in acquisition time did not affect quality parameters and lesion visibility for the appropriate reconstruction parameters, mainly in higher activities. However, image quality indicators are highly sensitive to the reconstruction parameters, producing significant differences (p < 0.05) in NSD, VCC, CNR and EC. Concluding, the reconstruction parameters need to be chosen carefully, considering patient's characteristics and administered activity, in order to produce the best relation image quality/lesion visibility and dose.
引用
收藏
页码:703 / 707
页数:5
相关论文
共 16 条
  • [1] Motion reduction activities in patients undergoing myocardial perfusion SPECT with the Discovery NM 530c(D530c)
    Lee, D.
    Choi, W.
    Jung, W.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S890 - S890
  • [2] 4D Reconstruction of dynamic studies performed using Discovery NM 530c
    Nakano, Sonoko
    Celler, Anna
    Pourmoghaddas, Amir
    Timmins, Rachel
    Trummer, Manfred
    Farncombe, Troy
    Wells, R. Glenn
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [3] Coronary Flow Reserve (CFR) Obtained with SPECT Discovery NM 530c Camera - Comparison with Coronary Angiography
    Blaszczyk, M.
    Cichocki, P.
    Cygulska, K.
    Kusmierek, J.
    Lipiec, P.
    Kasprzak, J. D.
    Frynas-Jonczyk, K.
    Wejner-Mik, P.
    Plachcinska, A.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S529 - S529
  • [4] Is Data-Driven Cardiac Gating Possible with REGAT Software Applied to SPECT Myocardial Perfusion Imaging Acquired with Discovery NM 530c?
    Daou, D.
    Sabbah, R.
    Bouladhour, H.
    Coaguila, C.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S518 - S518
  • [5] Data-driven respiratory-motion correction of myocardial perfusion SPECT imaging with Discovery NM 530c
    Daou, Doumit
    Sabbah, Remy
    Aladalah, Abdullah
    Monsarrat, Olivier
    Coaguila, Carlos
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [6] Feasibility of Data-Driven Respiratory-Motion Correction of Myocardial Perfusion SPECT with CZT Discovery NM 530c
    Daou, D.
    Sabbah, R.
    Boulandour, H.
    Coaguila, C.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S246 - S246
  • [7] Impact of Data-Driven Respiratory-Motion Correction on the Extent/Severity of Myocardial Perfusion Defects of MPI SPECT Acquired with Discovery NM 530c: REGAT Software
    Daou, D.
    Sabbah, R.
    Bouladhour, H.
    Coaguila, C.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S230 - S230
  • [8] Data-driven respiratory-motion correction with CZT Discovery NM 530c: impact on extent/severity of myocardial perfusion defects
    Daou, Doumit
    Sabbah, Remy
    Coaguila, Carlos
    Boulahdour, Hatem
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [9] New reconstruction algorithm for cardiac SPECT with shortened acquisition Time: impact on cardiac functional Analysis
    Valenta, I.
    Treyer, V.
    Husmann, L.
    Gaemperli, O.
    Schindler, M.
    Herzog, B. A.
    Schindler, T. H.
    Kaufmann, P. A.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S253 - S253
  • [10] Effects of varying acquisition and reconstruction parameters on image quality in pinhole SPECT imaging of mice.
    Dahlbom, M
    MacDonald, L
    Patt, BE
    Iwanczyk, JS
    Hoffman, EJ
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 212P - 212P