SR-4000 and CamCube3.0 Time of Flight (ToF) Cameras: Tests and Comparison

被引:45
|
作者
Piatti, Dario [1 ]
Rinaudo, Fulvio [1 ]
机构
[1] Politecn Torino, DITAG, I-10129 Turin, Italy
关键词
Time-of-Flight; SwissRanger; PMD; warm up; measurement precision; sunlight influence; RANGE; CALIBRATION; ARRAY;
D O I
10.3390/rs4041069
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this paper experimental comparisons between two Time-of-Flight (ToF) cameras are reported in order to test their performance and to give some procedures for testing data delivered by this kind of technology. In particular, the SR-4000 camera by Mesa Imaging AG and the CamCube3.0 by PMD Technologies have been evaluated since they have good performances and are well known to researchers dealing with Time-of-Flight (ToF) cameras. After a brief overview of commercial ToF cameras available on the market and the main specifications of the tested devices, two topics are presented in this paper. First, the influence of camera warm-up on distance measurement is analyzed: a warm-up of 40 minutes is suggested to obtain the measurement stability, especially in the case of the CamCube3.0 camera, that exhibits distance measurement variations of several centimeters. Secondly, the variation of distance measurement precision variation over integration time is presented: distance measurement precisions of some millimeters are obtained in both cases. Finally, a comparison between the two cameras based on the experiments and some information about future work on evaluation of sunlight influence on distance measurements are reported.
引用
收藏
页码:1069 / 1089
页数:21
相关论文
共 50 条
  • [41] Classification of Nephrite Using Calibration-Free Laser Induced Breakdown Spectroscopy (CF-LIBS) with Comparison to Laser Ablation-Time-of-Flight-Mass Spectrometry (LA-TOF-MS)
    Umar, Zeshan Adeel
    Liaqat, Usman
    Ahmed, Rizwan
    Baig, Muhammad Aslam
    ANALYTICAL LETTERS, 2020, 53 (02) : 203 - 216
  • [42] Identifying bacteria using a matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometer. Comparison with routine methods used in clinical microbiology laboratories
    Ferreira, Laura
    Vega, Silvia
    Sanchez-Juanes, Fernando
    Gonzalez, Magdalena
    Herrero, Ana
    Carmen Muniz, Ma
    Manuel Gonzalez-Buitrago, Jose
    Luis Munoz, Juan
    ENFERMEDADES INFECCIOSAS Y MICROBIOLOGIA CLINICA, 2010, 28 (08): : 492 - 497
  • [43] Comparison of Matrix-assisted Laser Desorption Ionization Time-of-flight Mass Spectrometry (MALDI-TOF MS) and the Vitek 2 System for Routine Identification of Clinically Relevant Bacteria and Yeast
    Garza-Gonzalez, Elvira
    Camacho-Ortiz, Adrian
    Rodriguez-Noriega, Eduardo
    Esparza-Ahumada, Sergio
    Flores-Trevino, Samantha
    Bocanegra-Ibarias, Paola
    Tijerina-Rodriguez, Laura
    Morfin-Otero, Rayo
    ANNALS OF CLINICAL AND LABORATORY SCIENCE, 2020, 50 (01): : 119 - 127
  • [44] Comparison of two matrix-assisted laser desorption/ionization-time of flight (MALDI-TOF) mass spectrometry methods and API 20AN for identification of clinically relevant anaerobic bacteria
    Jamal, Wafaa Y.
    Shahin, May
    Rotimi, Vincent O.
    JOURNAL OF MEDICAL MICROBIOLOGY, 2013, 62 : 540 - 544
  • [45] Investigation of the presence of carbapenemases in carbapenem-resistant Klebsiella pneumoniae strains by MALDI-TOF MS (matrix-assisted laser desorption ionization-time of flight mass spectrometry) and comparison with real-time PCR method
    Melike, Yas Comma Ar-Duman
    Cilli, Fatma Feriha
    INDIAN JOURNAL OF MEDICAL MICROBIOLOGY, 2021, 39 (03) : 300 - 305
  • [46] Comparison of quad rupole-time-of-flight (Q-tof), triple quadrupole, and ion-trap mass spectrometry/mass spectrometry (MS/MS) for the analysis of unknown pesticides and pharmaceuticals in water.
    Thurman, EM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 223 : U510 - U510
  • [47] Eddy covariance emission and deposition flux measurements using proton transfer reaction - time of flight - mass spectrometry (PTR-TOF-MS): comparison with PTR-MS measured vertical gradients and fluxes
    Park, J. -H.
    Goldstein, A. H.
    Timkovsky, J.
    Fares, S.
    Weber, R.
    Karlik, J.
    Holzinger, R.
    ATMOSPHERIC CHEMISTRY AND PHYSICS, 2013, 13 (03) : 1439 - 1456
  • [48] Comparison of Mechanical Disruption Techniques for Rapid Inactivation of Mycobacterium and Nocardia Species before Identification Using Matrix-Assisted Laser Desorption Ionization-Time of Flight (MALDI-TOF) Mass Spectrometry
    Totty, Heather
    Miller, Eric
    Moreno, Erik
    Dunne, W. Michael, Jr.
    Deol, Parampal
    JOURNAL OF CLINICAL MICROBIOLOGY, 2016, 54 (10) : 2626 - 2627
  • [49] Evaluation of Time of flight (TOF) and Point Spread Function (PSF) reconstructions in the Quantification of Myocardial Blood Flow with 13N Ammonia and PET: Comparison Among Reconstructions (Reprojection, OSEM), Software (PMOD and CARIMAS) and Operators
    Presotto, L.
    Busnardo, E.
    Bettinardi, V.
    Landoni, C.
    Todeschini, P.
    Rimoldi, O.
    Gilardi, M. C.
    Gianolli, L.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3979 - 3982
  • [50] Poly-dimethyl-siloxane (PDMS) contamination of polystyrene (PS) oligomers samples:: a comparison of time-of-flight static secondary ion mass spectrometry (TOF-SSIMS) and X-ray photoelectron spectroscopy (XPS) results
    Oran, U
    Ünveren, E
    Wirth, T
    Unger, WES
    APPLIED SURFACE SCIENCE, 2004, 227 (1-4) : 318 - 324