SR-4000 and CamCube3.0 Time of Flight (ToF) Cameras: Tests and Comparison

被引:45
|
作者
Piatti, Dario [1 ]
Rinaudo, Fulvio [1 ]
机构
[1] Politecn Torino, DITAG, I-10129 Turin, Italy
关键词
Time-of-Flight; SwissRanger; PMD; warm up; measurement precision; sunlight influence; RANGE; CALIBRATION; ARRAY;
D O I
10.3390/rs4041069
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this paper experimental comparisons between two Time-of-Flight (ToF) cameras are reported in order to test their performance and to give some procedures for testing data delivered by this kind of technology. In particular, the SR-4000 camera by Mesa Imaging AG and the CamCube3.0 by PMD Technologies have been evaluated since they have good performances and are well known to researchers dealing with Time-of-Flight (ToF) cameras. After a brief overview of commercial ToF cameras available on the market and the main specifications of the tested devices, two topics are presented in this paper. First, the influence of camera warm-up on distance measurement is analyzed: a warm-up of 40 minutes is suggested to obtain the measurement stability, especially in the case of the CamCube3.0 camera, that exhibits distance measurement variations of several centimeters. Secondly, the variation of distance measurement precision variation over integration time is presented: distance measurement precisions of some millimeters are obtained in both cases. Finally, a comparison between the two cameras based on the experiments and some information about future work on evaluation of sunlight influence on distance measurements are reported.
引用
收藏
页码:1069 / 1089
页数:21
相关论文
共 50 条
  • [21] Comparison of normalisation methods for surface-enhanced laser desorption and ionisation (SELDI) time-of-flight (TOF) mass spectrometry data
    Wouter Meuleman
    Judith YMN Engwegen
    Marie-Christine W Gast
    Jos H Beijnen
    Marcel JT Reinders
    Lodewyk FA Wessels
    BMC Bioinformatics, 9
  • [22] AN ANALYTICAL COMPARISON BETWEEN BISMUTH-GERMANATE BGO AND BARIUM FLUORIDE SCINTILLATORS FOR NON-TIME-OF-FLIGHT POSITRON EMISSION TOMOGRAPHY CAMERAS
    WONG, WH
    JOURNAL OF NUCLEAR MEDICINE, 1985, 26 (05) : P100 - P100
  • [23] A comparison of 4D time-resolved MRA with keyhole and 3D time-of-flight MRA at 3.0 T for the evaluation of cerebral aneurysms
    Qian Wu
    Ming-Hua Li
    BMC Neurology, 12
  • [24] A comparison of 4D time-resolved MRA with keyhole and 3D time-of-flight MRA at 3.0 T for the evaluation of cerebral aneurysms
    Wu, Qian
    Li, Ming-Hua
    BMC NEUROLOGY, 2012, 12
  • [25] Comparison of 3.0-and 1.5-T three-dimensional time-of-flight MR angiography in Moyamoya disease: Preliminary experience
    Fushimi, Y
    Miki, Y
    Kikuta, K
    Okada, T
    Kanagaki, M
    Yamamoto, A
    Nozaki, K
    Hashimoto, N
    Hanakawa, T
    Fukuyama, H
    Togashi, K
    RADIOLOGY, 2006, 239 (01) : 232 - 237
  • [26] Evaluation of cerebral arteriovenous shunts: a comparison of parallel imaging time-of-flight magnetic resonance angiography (TOF-MRA) and compressed sensing TOF-MRA to digital subtraction angiography
    Akihiko Sakata
    Yasutaka Fushimi
    Tomohisa Okada
    Satoshi Nakajima
    Takuya Hinoda
    Peter Speier
    Michaela Schmidt
    Christoph Forman
    Kazumichi Yoshida
    Hiroharu Kataoka
    Susumu Miyamoto
    Yuji Nakamoto
    Neuroradiology, 2021, 63 : 879 - 887
  • [27] Evaluation of cerebral arteriovenous shunts: a comparison of parallel imaging time-of-flight magnetic resonance angiography (TOF-MRA) and compressed sensing TOF-MRA to digital subtraction angiography
    Sakata, Akihiko
    Fushimi, Yasutaka
    Okada, Tomohisa
    Nakajima, Satoshi
    Hinoda, Takuya
    Speier, Peter
    Schmidt, Michaela
    Forman, Christoph
    Yoshida, Kazumichi
    Kataoka, Hiroharu
    Miyamoto, Susumu
    Nakamoto, Yuji
    NEURORADIOLOGY, 2021, 63 (06) : 879 - 887
  • [28] Angiographic contrast mechanism comparison between Simultaneous Non-contrast Angiography and intraPlaque hemorrhage (SNAP) sequence and Time of Flight (TOF) sequence for intracranial artery
    Zhang, Qiang
    Chen, Zhensen
    Chen, Shuo
    Liu, Xinke
    Ning, Jia
    Han, Yongjun
    Chen, Li
    He, Le
    Zhao, Xihai
    Xiong, Yuhui
    Guo, Hua
    Yuan, Chun
    Li, Rui
    Chen, Huijun
    MAGNETIC RESONANCE IMAGING, 2020, 66 : 199 - 207
  • [29] Grouping myxococci (Corallococcus) strains by Matrix-Assisted Laser Desorption Ionization Time-of-Flight (MALDI TOF) mass spectrometry:: Comparison with gene sequence phylogenies
    Stackebrandt, E
    Päuker, O
    Erhard, M
    CURRENT MICROBIOLOGY, 2005, 50 (02) : 71 - 77
  • [30] Comparison of matrix-assisted laser desorption ionization time of flight mass spectrometry (MALDI-TOF MS) systems for the identification of moulds in the routine microbiology laboratory
    Dupont, D.
    Normand, A. -C.
    Persat, F.
    Hendrickx, M.
    Piarroux, R.
    Wallon, M.
    CLINICAL MICROBIOLOGY AND INFECTION, 2019, 25 (07) : 892 - 897