SR-4000 and CamCube3.0 Time of Flight (ToF) Cameras: Tests and Comparison

被引:45
|
作者
Piatti, Dario [1 ]
Rinaudo, Fulvio [1 ]
机构
[1] Politecn Torino, DITAG, I-10129 Turin, Italy
关键词
Time-of-Flight; SwissRanger; PMD; warm up; measurement precision; sunlight influence; RANGE; CALIBRATION; ARRAY;
D O I
10.3390/rs4041069
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this paper experimental comparisons between two Time-of-Flight (ToF) cameras are reported in order to test their performance and to give some procedures for testing data delivered by this kind of technology. In particular, the SR-4000 camera by Mesa Imaging AG and the CamCube3.0 by PMD Technologies have been evaluated since they have good performances and are well known to researchers dealing with Time-of-Flight (ToF) cameras. After a brief overview of commercial ToF cameras available on the market and the main specifications of the tested devices, two topics are presented in this paper. First, the influence of camera warm-up on distance measurement is analyzed: a warm-up of 40 minutes is suggested to obtain the measurement stability, especially in the case of the CamCube3.0 camera, that exhibits distance measurement variations of several centimeters. Secondly, the variation of distance measurement precision variation over integration time is presented: distance measurement precisions of some millimeters are obtained in both cases. Finally, a comparison between the two cameras based on the experiments and some information about future work on evaluation of sunlight influence on distance measurements are reported.
引用
收藏
页码:1069 / 1089
页数:21
相关论文
共 50 条
  • [31] Grouping Myxococci (Corallococcus) Strains by Matrix-Assisted Laser Desorption Ionization Time-of-Flight (MALDI TOF) Mass Spectrometry: Comparison with Gene Sequence Phylogenies
    Erko Stackebrandt
    Orsola Päuker
    Marcel Erhard
    Current Microbiology, 2005, 50 : 71 - 77
  • [32] Gas Chromatography Time-Of-Flight Mass Spectrometry (GC-TOF-MS)-Based Metabolomics for Comparison of Caffeinated and Decaffeinated Coffee and Its Implications for Alzheimer's Disease
    Chang, Kai Lun
    Ho, Paul C.
    PLOS ONE, 2014, 9 (08):
  • [33] Comparison of hydrolysis products of AlCl3 • 6H2O in different concentrations by electrospray ionization time of flight mass spectrometer (ESI TOF MS)
    Sarpola, Arja T.
    Hietapelto, Vesa K.
    Jalonen, Jorma E.
    Jokela, Jukka
    Ramo, Jaakko H.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2006, 86 (13) : 1007 - 1018
  • [34] Comparison of Two Commercial Matrix-Assisted Laser Desorption/Ionization-Time of Flight Mass Spectrometry (MALDI-TOF MS) Systems for Identification of Nontuberculous Mycobacteria
    Brown-Elliott, Barbara A.
    Fritsche, Thomas R.
    Olson, Brooke J.
    Vasireddy, Sruthi
    Vasireddy, Ravikiran
    Iakhiaeva, Elena
    Alame, Diana
    Wallace, Richard J., Jr.
    Branda, John A.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2019, 152 (04) : 527 - 536
  • [35] The Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry (MALDI-TOF MS) identification versus biochemical tests: a study with enterobacteria from a dairy cattle environment
    Bento Rodrigues, Naiara Miranda
    Bronzato, Greiciane Franca
    Santiago, Gabrielli Stefaninni
    Batista Botelho, Larissa Alvarenga
    Moreira, Beatriz Meurer
    Coelho, Irene da Silva
    Soares de Souza, Miliane Moreira
    de Oliveira Coelho, Shana de Mattos
    BRAZILIAN JOURNAL OF MICROBIOLOGY, 2017, 48 (01) : 132 - 138
  • [36] Comparison of adult, fetal and recombinant human fibrinogen by screening with matrix-assisted laser-desorption/ionization time-of flight (MALDI-TOF) mass spectrometry (MS)
    Henschen-Edman, AH
    Galanakis, DK
    Lord, ST
    THROMBOSIS AND HAEMOSTASIS, 1999, : 600 - 600
  • [37] Comparison of biomarker based Matrix Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry (MALDI-TOF MS) and conventional methods in the identification of clinically relevant bacteria and yeast
    Kassim, Ali
    Pfluger, Valentin
    Premji, Zul
    Daubenberger, Claudia
    Revathi, Gunturu
    BMC MICROBIOLOGY, 2017, 17
  • [38] Comparison of biomarker based Matrix Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry (MALDI-TOF MS) and conventional methods in the identification of clinically relevant bacteria and yeast
    Ali Kassim
    Valentin Pflüger
    Zul Premji
    Claudia Daubenberger
    Gunturu Revathi
    BMC Microbiology, 17
  • [39] Comparison of Saramis 4.12 and IVD 3.0 Vitek MS Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Identification of Mycobacteria from Solid and Liquid Culture Media
    Leyer, Caroline
    Gregorowicz, Guillaume
    Mougari, Faiza
    Raskine, Laurent
    Cambau, Emmanuelle
    de Briel, Dominique
    JOURNAL OF CLINICAL MICROBIOLOGY, 2017, 55 (07) : 2045 - 2054
  • [40] Comparison of Matrix-Assisted Laser Desorption Ionization-Time of Flight (MALDI-TOF) Mass Spectrometry Platforms for the Identification of Gram-Negative Rods from Patients with Cystic Fibrosis
    Alby, Kevin
    Gilligan, Peter H.
    Miller, Melissa B.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2013, 51 (11) : 3852 - 3854