Initial Stability Measurements of Implants Using a New Magnetic Resonance Frequency Analyzer With Titanium Transducers: An Ex Vivo Study

被引:16
|
作者
Bural, Canan [1 ]
Dayan, Cagatay [2 ]
Geckili, Onur [1 ]
机构
[1] Istanbul Cerrahpasa Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkey
[2] Istanbul Univ, Program Dent Technicians, Istanbul, Turkey
关键词
osseointegration; implantology; experimental design; implant stability; resonance frequency; dental implant; IN-VITRO; DENTAL IMPLANTS; DEVICES; DESIGNS;
D O I
10.1563/aaid-joi-D-19-00126
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The establishment of dental implant stability is mandatory for successful osseointegration. Resonance frequency analysis (RFA) is the most frequently used method for the clinical measurement of implant stability. The purpose of the present study was to evaluate the reliability of the recently developed RF analyzer Penguin RFA and to compare it with the traditional RF analyzer Osstell ISQ. Sixty implants were inserted into fresh steer vertebrae and pelvis. Implant stability was measured using Penguin RFA by its transducers (multipegs) and Osstell ISQ by its transducers (smartpegs). Additionally, stability was measured by multipegs with Osstell ISQ and by smartpegs with Penguin RFA. The intraobserver and interobserver reliability of Penguin RFA were estimated by the intraclass coefficient (ICC). Mean implant stability quotients (ISQs) measured with Osstell ISQ were higher than the ISQs measured with Penguin RFA (P < .05). The intra- and interobserver reliability of Penguin RFA were considered as excellent (ICC > 0.7). For Osstell ISQ, no significance in ISQs was detected between the readings by smartpegs and multipegs (P > .05), while for Penguin RFA ISQs by smartpegs were significantly higher than the ISQs by multipegs (P <.05). The recently developed Penguin RFA is reliable and can be used in clinical practice for the measurement of dental implant stability regardless of the bone type. The multipegs originally manufactured for the Penguin RFA is also compatible with Osstell ISQ.
引用
收藏
页码:35 / 40
页数:6
相关论文
共 37 条
  • [1] The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia
    Meredith, N
    Shagaldi, F
    Alleyne, D
    Sennerby, L
    Cawley, P
    CLINICAL ORAL IMPLANTS RESEARCH, 1997, 8 (03) : 234 - 243
  • [2] Evaluation of effect on stability of implants with and without platelet rich fibrin using a resonance frequency analyzer- An in-vivo study
    Anapu, Mounica Priya
    Atluri, Kaleswara Rao
    Tripuraneni, Sunil Chandra
    Issrani, Rakhi
    Bader, Alzarea K.
    Alkhalaf, Zainab A.
    Sghaireen, Mohammed Ghazi
    Prabhu, Namdeo
    Alshammari, Raed Rbea D. H.
    Khalid, Ghosoun
    Matab, Ghada
    Khan, Farida Habib
    HELIYON, 2024, 10 (07)
  • [3] Resonance frequency measurements of implant stability in vivo - A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla
    Meredith, N
    Book, K
    Friberg, B
    Jemt, T
    Sennerby, L
    CLINICAL ORAL IMPLANTS RESEARCH, 1997, 8 (03) : 226 - 233
  • [4] Stability measurements of cranio-facial implants using resonance frequency analysis
    Meredith, N
    Heo, SJ
    Sennerby, L
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 1024 - 1024
  • [5] A comparative study on the initial stability of different implants placed above the bone level using resonance frequency analysis
    Kang, In-Ho
    Kim, Chang-Whe
    Lim, Young-Jun
    Kim, Myung-Joo
    JOURNAL OF ADVANCED PROSTHODONTICS, 2011, 3 (04): : 190 - 195
  • [6] Safety of 3 Tesla Magnetic Resonance Imaging on iStent Implants: An Ex-Vivo Study
    Ayalon, Anfisa
    Fanadka, Feda
    Belkin, Avner
    Burgansky, Zvia
    Moisseiev, Elad
    JOURNAL OF GLAUCOMA, 2021, 30 (05) : E252 - E255
  • [7] Study of the aging process of PDMS implants in-vivo and ex-vivo by magnetic resonance spectroscopy and imaging
    Pfleiderer, B.
    Moore, J.
    Ackerman, J.L.
    Garrido, L.
    Polymer Preprints, Division of Polymer Chemistry, American Chemical Society, 1992, 33 (01):
  • [8] Stability measurements of craniofacial implants by means of resonance frequency analysis. A clinical pilot study
    Heo, SJ
    Sennerby, L
    Odersjo, M
    Granstrom, G
    Tjellstrom, A
    Meredith, N
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1998, 112 (06): : 537 - 542
  • [9] Stability measurements of 1-stage implants in the maxilla by means of resonance frequency analysis: A pilot study
    Zix, J
    Kessler-Liechti, G
    Mericske-Stern, D
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2005, 20 (05) : 747 - 752
  • [10] Determination of the Optimum Torque to Tighten the Smartpegs of Magnetic Resonance Frequency Analyses Devices: An Ex Vivo Study
    Geckili, Onur
    Cilingir, Altug
    Bural, Canan
    Bilmenoglu, Caglar
    Bilhan, Hakan
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (06) : E252 - E256