A comparative study on the initial stability of different implants placed above the bone level using resonance frequency analysis

被引:7
|
作者
Kang, In-Ho [1 ]
Kim, Chang-Whe [1 ]
Lim, Young-Jun [1 ]
Kim, Myung-Joo [1 ]
机构
[1] Seoul Natl Univ, Sch Dent, Dept Prosthodont, Grad Sch, Seoul 110768, South Korea
来源
JOURNAL OF ADVANCED PROSTHODONTICS | 2011年 / 3卷 / 04期
关键词
Effective implant length; Initial stability; Implant design; Resonance frequency analysis; TITANIUM IMPLANTS; IDENTIFICATION;
D O I
10.4047/jap.2011.3.4.190
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. This study evaluated the initial stability of different implants placed above the bone level in different types of bone. MATERIALS AND METHODS. As described by Lekholm and Zarb, cortical layers of bovine bone specimens were trimmed to a thickness of 2 mm, 1 mm or totally removed to reproduce bone types II, III, and IV respectively. Three Implant system (Branemark System (R) Mk III TiUnite (TM), Straumann Standard Implant SLA (R), and Astra Tech Microthread (TM)-OsseoSpeed (TM)) were tested. Control group implants were placed in level with the bone, while test group implants were placed 1, 2, 3, and 4 mm above the bone level. Initial stability was evaluated by resonance frequency analysis. Data was statistically analyzed by one-way analysis of variance in confidence level of 95%. The effective implant length and the Implant Stability Quotient (ISQ) were compared using simple linear regression analysis. RESULTS. In the control group, there was a significant difference in the ISQ values of the 3 implants in bone types III and IV (P<.05). The ISQ values of each implant decreased with increased effective implant length in all types of bone. In type II bone, the decrease in ISQ value per 1-mm increase in effective implant length of the Branemark and Astra implants was less than that of the Straumann implant. In bone types III and IV, this value in the Astra implant was less than that in the other 2 implants. CONCLUSION. The initial stability was much affected by the implant design in bone types III, IV and the implant design such as the short pitch interval was beneficial to the initial stability of implants placed above the bone level. [J Adv Prosthodont 2011;3: 190-5]
引用
收藏
页码:190 / 195
页数:6
相关论文
共 50 条
  • [1] Resonance frequency analysis of implants placed in condensed bone
    Feher, Balazs
    Frommlet, Florian
    Gruber, Reinhard
    Hirtler, Lena
    Ulm, Christian
    Kuchler, Ulrike
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (10) : 1200 - 1208
  • [2] Assessment of the Correlation Between Insertion Torque and Resonance Frequency Analysis of Implants Placed in Bone Tissue of Different Densities
    Magno Filho, Luiz Carlos
    Cirano, Fabiano Ribeiro
    Hayashi, Fernando
    Feng, Hsu Shao
    Conte, Alexandre
    Dib, Luciano Lauria
    Casati, Marcio Zaffalon
    JOURNAL OF ORAL IMPLANTOLOGY, 2014, 40 (03) : 259 - 262
  • [3] Primary Stability of Implants Placed at Different Angulations in Artificial Bone
    Kashi, Ajay
    Gupta, Bhumija
    Malmstrom, Hans
    Romanos, Georgios E.
    IMPLANT DENTISTRY, 2015, 24 (01) : 92 - 95
  • [4] Primary stability and bone deformation induced by tapered implants in different bone densities: a microtomography and resonance frequency analysis
    P. Faria
    A. Vieta
    F. A. Oliveira
    V. F. Carvalho
    S. L. S. Souza
    Mario Taba
    Periodontal and Implant Research, 9 (1)
  • [5] Resonance frequency analysis (RFA) and insertional torque (IT) stability comparisons of implants placed using osteotomes versus drilling techniques: A preliminary case study
    Xing, Yi
    Khandelwal, Namita
    Petrov, Sofia
    Drew, Howard J.
    Mupparapu, Mel
    QUINTESSENCE INTERNATIONAL, 2015, 46 (09): : 789 - 798
  • [6] Measurement of Primary Stability of Mini Implants Using Resonance Frequency Analysis
    Singh, Ashish Kumar
    Kannan, Sridhar
    Arora, Nitin
    Bajaj, Yatin
    Revankar, Ameet V.
    APOS TRENDS IN ORTHODONTICS, 2018, 8 (03) : 139 - 145
  • [7] Using Resonance Frequency Analysis to Compare Delayed and Immediate Progressive Loading for Implants Placed in the Posterior Maxilla: A Pilot Study
    AL Juboori, Mohammed Jasim
    AL Attas, Mohammed Ahmed
    Gomes, Raquel Zita
    Alanbari, Basma Fathi
    OPEN DENTISTRY JOURNAL, 2018, 12 : 801 - 810
  • [8] Implants in Reconstructed Bone: A Comparative Study on the Outcome of Straumann® Tissue Level and Bone Level Implants Placed in Vertically Deficient Alveolar Ridges Treated by Means of Autogenous Onlay Bone Grafts
    Chiapasco, Matteo
    Casentini, Paolo
    Zaniboni, Marco
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2014, 16 (01) : 32 - 50
  • [9] Healing at implants placed in bone of different morphology: an experimental study in dogs
    Caroprese, Marino
    Soldini, Claudio
    Ricci, Sara
    Rea, Massimiliano
    Lang, Niklaus P.
    Botticelli, Daniele
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (08) : 961 - 965
  • [10] Challenges of Using Resonance Frequency Analysis to Identify Stability of a Dental Implant Placed in the Mandible
    Liu, Yifeng
    Sorensen, John
    Shen, I
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (02) : E7 - E21