A comparative study on the initial stability of different implants placed above the bone level using resonance frequency analysis

被引:7
|
作者
Kang, In-Ho [1 ]
Kim, Chang-Whe [1 ]
Lim, Young-Jun [1 ]
Kim, Myung-Joo [1 ]
机构
[1] Seoul Natl Univ, Sch Dent, Dept Prosthodont, Grad Sch, Seoul 110768, South Korea
来源
JOURNAL OF ADVANCED PROSTHODONTICS | 2011年 / 3卷 / 04期
关键词
Effective implant length; Initial stability; Implant design; Resonance frequency analysis; TITANIUM IMPLANTS; IDENTIFICATION;
D O I
10.4047/jap.2011.3.4.190
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. This study evaluated the initial stability of different implants placed above the bone level in different types of bone. MATERIALS AND METHODS. As described by Lekholm and Zarb, cortical layers of bovine bone specimens were trimmed to a thickness of 2 mm, 1 mm or totally removed to reproduce bone types II, III, and IV respectively. Three Implant system (Branemark System (R) Mk III TiUnite (TM), Straumann Standard Implant SLA (R), and Astra Tech Microthread (TM)-OsseoSpeed (TM)) were tested. Control group implants were placed in level with the bone, while test group implants were placed 1, 2, 3, and 4 mm above the bone level. Initial stability was evaluated by resonance frequency analysis. Data was statistically analyzed by one-way analysis of variance in confidence level of 95%. The effective implant length and the Implant Stability Quotient (ISQ) were compared using simple linear regression analysis. RESULTS. In the control group, there was a significant difference in the ISQ values of the 3 implants in bone types III and IV (P<.05). The ISQ values of each implant decreased with increased effective implant length in all types of bone. In type II bone, the decrease in ISQ value per 1-mm increase in effective implant length of the Branemark and Astra implants was less than that of the Straumann implant. In bone types III and IV, this value in the Astra implant was less than that in the other 2 implants. CONCLUSION. The initial stability was much affected by the implant design in bone types III, IV and the implant design such as the short pitch interval was beneficial to the initial stability of implants placed above the bone level. [J Adv Prosthodont 2011;3: 190-5]
引用
收藏
页码:190 / 195
页数:6
相关论文
共 50 条
  • [21] Resonance frequency analysis of implants placed with osteotome sinus floor elevation in posterior maxillae
    Qian, Shu-Jiao
    Gu, Ying-Xin
    Mo, Jia-Ji
    Qiao, Shi-Chong
    Zhuang, Long-Fei
    Lai, Hong-Chang
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (01) : 113 - 119
  • [22] The influence of fixation in formalin on the measurement of stability of implants using resonance frequency analysis and Periotest M®: A study in a dog
    Doi, Kazuya
    Kajihara, Shiho
    Morita, Koji
    Makihara, Yusuke
    Okada, Shinsuke
    Akagawa, Yasumasa
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2014, 52 (01): : 29 - 33
  • [23] To compare the stability and crestal bone loss of implants placed using osseodensification and traditional drilling protocol: A clinicoradiographical study
    Sultana, Anjum
    Makkar, Sumit
    Saxena, Deepesh
    Wadhawan, Amit
    Kusum, Chandan Kumar
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2020, 20 (01): : 45 - 51
  • [24] Initial stability measurement of dental implants placed in different anatomical regions of fresh human cadaver jawbone
    Seong, Wook-Jin
    Holte, James E.
    Holtan, James R.
    Olin, Paul S.
    Hodges, James S.
    Ko, Ching-Chang
    JOURNAL OF PROSTHETIC DENTISTRY, 2008, 99 (06): : 425 - 434
  • [25] A Retrospective Study of Bone Level Stability Around 441 Mandibular and 350 Maxillary Molar Implants Placed with an Immediate Implant Protocol
    Wagenberg, Barry
    Froum, Stuart J.
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2020, 40 (05) : 635 - 643
  • [26] Stability and Marginal Bone Level Changes of SLActive Titanium-Zirconium Implants Placed with Flapless Surgery: A Prospective Pilot Study
    Altinci, Pinar
    Can, Gulsen
    Gunes, Onur
    Ozturk, Caner
    Eren, Hakan
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2016, 18 (06) : 1193 - 1199
  • [27] A resonance frequency analysis of sandblasted and acid-etched implants with different diameters: a prospective clinical study during the initial healing period
    Kim, Hyun-Joo
    Kim, Yeun-Kang
    Joo, Ji-Young
    Lee, Ju-Youn
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2017, 47 (02): : 106 - 115
  • [28] Comparison of the primary stability achieved by using dental implants with variable thread designs when placed using different drilling techniques. An in vitro bone modular analysis
    Shetty, P. P.
    Chowdhary, R.
    JOURNAL OF OSSEOINTEGRATION, 2023, 15 (01) : 53 - 61
  • [29] A Clinical Resonance Frequency Analysis of Implants Placed at Dehiscence-Type Defects with Simultaneous Guided Bone Regeneration During Early Healing
    Janyaphadungpong, Rueangsiri
    Serichetaphongse, Pravej
    Pimkhaokham, Atiphan
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (03) : 772 - 777
  • [30] Stability measurements of craniofacial implants by means of resonance frequency analysis. A clinical pilot study
    Heo, SJ
    Sennerby, L
    Odersjo, M
    Granstrom, G
    Tjellstrom, A
    Meredith, N
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1998, 112 (06): : 537 - 542