The diagnostic value of single photon-emission computed tomography bone scans combined with CT (SPECT-CT) in diseases of the foot and ankle

被引:29
|
作者
Singh, Vinay Kumar [1 ]
Javed, Sadaf [2 ]
Parthipun, Arum [1 ]
Sott, Andrea Helene [1 ]
机构
[1] Epsom & St Helier Univ Hosp NHS Trust, Carshalton SM5 1AA, Surrey, England
[2] Barts & London NHS Trust, London E1 1BB, England
关键词
Foot; Ankle; SPECT-CT; Diagnostic;
D O I
10.1016/j.fas.2012.11.002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: A radionuclide bone scan with single photon-emission computed tomography and CT (SPECT-CT) is a new imaging modality which combines highly detailed CT with the functional information from a triple phase radionuclide bone scan. Little has been published about its diagnostic accuracy and usefulness in foot and ankle pathology. The aim of this study is to evaluate whether bone scans with SPECT-CT provide a useful contribution to the management of patients with foot and ankle pain, and whether it results in changes to clinical management. Methods: A retrospective study involving 50 patients was conducted between March 2010 and April 2011. SPECT-CT was requested in cases where definitive clinical diagnosis could not be achieved after clinical examination and plain radiography. Pathology as highlighted on SPECT-CT was taken as the definitive diagnosis in these patients and was treated accordingly. Patients were subsequently seen in the follow up clinic to evaluate the outcome of their treatment. Results: In 11 patients (22%), the provisional clinical diagnosis matched with the findings of the SPECT-CT and no change in treatment was necessary. In 39 patients (78%) the findings of the SPECT-CT did not correlate exactly with the initial clinical diagnosis and led to a modified treatment plan. The accuracy, sensitivity, specificity, positive predictive and negative predictive value of SPECT-CT in this series was 94%, 95.45%, 83.3%, 97.6% and 71.43% respectively. Conclusions: SPECT-CT is a useful investigation tool in foot and ankle pathologies. The present study shows a high diagnostic accuracy and we recommend its use in cases with diagnostic uncertainty. (C) 2012 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:80 / 83
页数:4
相关论文
共 50 条
  • [21] BRAIN SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY (SPECT) IN NEUROPEDIATRICS
    UVEBRANT, P
    BJURE, J
    HEDSTROM, A
    EKHOLM, S
    NEUROPEDIATRICS, 1991, 22 (01) : 3 - 9
  • [22] SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY (SPECT) IN SKELETAL SCINTIGRAPHY
    VANDEFLIERDT, E
    BAUER, R
    WAGNERMANSLAU, C
    LANGHAMMER, HR
    PABST, HW
    NUKLEARMEDIZINER, 1991, 14 (03): : 131 - 136
  • [23] SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY (SPECT) - 1989 AND BEYOND
    RITCHIE, JL
    CERQUEIRA, MD
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (07) : 1700 - 1701
  • [24] USE OF SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY (SPECT) IN ONCOLOGY
    OTT, RJ
    BRITISH JOURNAL OF CANCER, 1989, 59 (05) : 818 - 818
  • [25] Single photon emission computed tomography SPECT-CT improves sentinel node detection and localization in cervical and uterine malignancy
    Pandit-Taskar, Neeta
    Gemignani, Mary L.
    Lyall, Ashima
    Larson, Steven M.
    Barakat, Richard R.
    Abu Rustum, Nadeem R.
    GYNECOLOGIC ONCOLOGY, 2010, 117 (01) : 59 - 64
  • [26] Quantitative bone single photon emission computed tomography/computed tomography in symptomatic and asymptomatic foot and ankle osteoarthritis
    Ulrich, Martin
    Lehnick, Dirk
    Strobel, Klaus
    Gruenig, Hannes
    Lima, Thiago
    Iselin, Lukas
    Bhure, Ujwal
    NUCLEAR MEDICINE COMMUNICATIONS, 2024, 45 (10) : 848 - 857
  • [27] SPECT-CT contribution to conventional bone scintigraphy in the diagnosis of foot and ankle pain
    Caicedo, C. J.
    Vigil, C.
    Dominguez-Prado, I.
    Garcia-Velloso, M.
    Garrastachu, P.
    Rodriguez-Fraile, M.
    Gonzalez-Forero, M.
    Villas, C.
    Alfonso, M.
    Richter, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S348 - S348
  • [28] Lymphoscintigraphy combined with single-photon emission computed tomography-computed tomography (SPECT-CT): A very effective imaging approach for identification of the site of leak in postoperative chylothorax
    Das, Jayanta
    Thambudorai, Robin
    Ray, Soumendranath
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2015, 30 (02): : 177 - 179
  • [29] Axillary lymph node staging in breast cancer: clinical value of single photon emission computed tomography-computed tomography (SPECT-CT) with 99mTc-methoxyisobutylisonitrile
    Novikov, Sergey Nikolaevich
    Krzhivitskii, Pavel Ivanovich
    Kanaev, Sergey Vasilevich
    Krivorotko, Petr Vladimirovich
    Ilin, Nikolay Dmirievich
    Jukova, Ludmila Alexeevna
    Ponomareva, Olga Igorevna
    ANNALS OF NUCLEAR MEDICINE, 2015, 29 (02) : 177 - 183
  • [30] Axillary lymph node staging in breast cancer: clinical value of single photon emission computed tomography-computed tomography (SPECT-CT) with 99mTc-methoxyisobutylisonitrile
    Sergey Nikolaevich Novikov
    Pavel Ivanovich Krzhivitskii
    Sergey Vasilevich Kanaev
    Petr Vladimirovich Krivorotko
    Nikolay Dmirievich Ilin
    Ludmila Alexeevna Jukova
    Olga Igorevna Ponomareva
    Annals of Nuclear Medicine, 2015, 29 : 177 - 183