The diagnostic value of single photon-emission computed tomography bone scans combined with CT (SPECT-CT) in diseases of the foot and ankle

被引:29
|
作者
Singh, Vinay Kumar [1 ]
Javed, Sadaf [2 ]
Parthipun, Arum [1 ]
Sott, Andrea Helene [1 ]
机构
[1] Epsom & St Helier Univ Hosp NHS Trust, Carshalton SM5 1AA, Surrey, England
[2] Barts & London NHS Trust, London E1 1BB, England
关键词
Foot; Ankle; SPECT-CT; Diagnostic;
D O I
10.1016/j.fas.2012.11.002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: A radionuclide bone scan with single photon-emission computed tomography and CT (SPECT-CT) is a new imaging modality which combines highly detailed CT with the functional information from a triple phase radionuclide bone scan. Little has been published about its diagnostic accuracy and usefulness in foot and ankle pathology. The aim of this study is to evaluate whether bone scans with SPECT-CT provide a useful contribution to the management of patients with foot and ankle pain, and whether it results in changes to clinical management. Methods: A retrospective study involving 50 patients was conducted between March 2010 and April 2011. SPECT-CT was requested in cases where definitive clinical diagnosis could not be achieved after clinical examination and plain radiography. Pathology as highlighted on SPECT-CT was taken as the definitive diagnosis in these patients and was treated accordingly. Patients were subsequently seen in the follow up clinic to evaluate the outcome of their treatment. Results: In 11 patients (22%), the provisional clinical diagnosis matched with the findings of the SPECT-CT and no change in treatment was necessary. In 39 patients (78%) the findings of the SPECT-CT did not correlate exactly with the initial clinical diagnosis and led to a modified treatment plan. The accuracy, sensitivity, specificity, positive predictive and negative predictive value of SPECT-CT in this series was 94%, 95.45%, 83.3%, 97.6% and 71.43% respectively. Conclusions: SPECT-CT is a useful investigation tool in foot and ankle pathologies. The present study shows a high diagnostic accuracy and we recommend its use in cases with diagnostic uncertainty. (C) 2012 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:80 / 83
页数:4
相关论文
共 50 条
  • [31] 99MTC-MIBI SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY-COMPUTED TOMOGRAPHY (SPECT-CT) TO DETECT TUMOR PROGRESSION IN GLIOBLASTOMAS (GB)
    Victor, Carolina
    Lopez, Rossana
    Nunes, Rafael
    Marta, Gustavo
    Picarelli, Helder
    Buchpiguel, Carlos Alberto
    Feher, Olavo
    NEURO-ONCOLOGY, 2017, 19 : 149 - 149
  • [32] SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHY COMBINED WITH COMPUTED TOMOGRAPHY (SPECT/CT) TO DETECT SENTINEL LYMPH NODES IN BREAST CANCER
    Okesh, M.
    Avdeyev, A.
    Benberin, V
    Kudaibergenova, M.
    Shanazarov, N.
    Akhmedullin, R.
    Bariyeva, G.
    Aimanova, T.
    VALUE IN HEALTH, 2022, 25 (01) : S169 - S170
  • [33] Comparison of bone single-photon emission computed tomography (SPECT)/CT and bone scintigraphy in assessing knee joints
    Young-Sil An
    Do Young Park
    Byoung-Hyun Min
    Su Jin Lee
    Joon-Kee Yoon
    BMC Medical Imaging, 21
  • [34] Comparison of bone single-photon emission computed tomography (SPECT)/CT and bone scintigraphy in assessing knee joints
    An, Young-Sil
    Park, Do Young
    Min, Byoung-Hyun
    Lee, Su Jin
    Yoon, Joon-Kee
    BMC MEDICAL IMAGING, 2021, 21 (01)
  • [35] The Utility of Metaiodobenzylguanidine Single Photon Emission Computed Tomography/Computed Tomography (MIBG SPECT/CT) for the Diagnosis of Pheochromocytoma
    Goswin Y. Meyer-Rochow
    Geoff P. Schembri
    Diana E. Benn
    Mark S. Sywak
    Leigh W. Delbridge
    Bruce G. Robinson
    Paul J. Roach
    Stan B. Sidhu
    Annals of Surgical Oncology, 2010, 17 : 392 - 400
  • [36] The Utility of Metaiodobenzylguanidine Single Photon Emission Computed Tomography/Computed Tomography (MIBG SPECT/CT) for the Diagnosis of Pheochromocytoma
    Meyer-Rochow, Goswin Y.
    Schembri, Geoff P.
    Benn, Diana E.
    Sywak, Mark S.
    Delbridge, Leigh W.
    Robinson, Bruce G.
    Roach, Paul J.
    Sidhu, Stan B.
    ANNALS OF SURGICAL ONCOLOGY, 2010, 17 (02) : 392 - 400
  • [37] THALLIUM STUDIES USING SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY (SPECT)
    COLEMAN, RE
    COBB, FR
    JASZCZAK, RJ
    JOURNAL OF NUCLEAR MEDICINE, 1981, 22 (06) : P11 - P11
  • [38] Clinical Value of Combined Single Photon Emission Computerized Tomography and Conventional Computer Tomography (SPECT/CT) in Sports Medicine
    Hirschmann, Michael Tobias
    Davda, Kinner
    Rasch, Helmut
    Arnold, Markus P.
    Friederich, Niklaus F.
    SPORTS MEDICINE AND ARTHROSCOPY REVIEW, 2011, 19 (02): : 174 - 181
  • [39] The improved accuracy of planar bone scintigraphy by adding single photon emission computed tomography (SPECT-CT) to detect skeletal metastases from prostate cancer
    McLoughlin, L. C.
    O'Kelly, F.
    O'Brien, C.
    Sheikh, M.
    Feeney, J.
    Torreggiani, W.
    Thornhill, J. A.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2016, 185 (01) : 101 - 105
  • [40] The improved accuracy of planar bone scintigraphy by adding single photon emission computed tomography (SPECT-CT) to detect skeletal metastases from prostate cancer
    L. C. McLoughlin
    F. O’Kelly
    C. O’Brien
    M. Sheikh
    J. Feeney
    W. Torreggiani
    J. A. Thornhill
    Irish Journal of Medical Science (1971 -), 2016, 185 : 101 - 105