Influence of custom-made and prefabricated insoles before and after an intense run

被引:19
|
作者
Gabriel Lucas-Cuevas, Angel [1 ]
Camacho-Garcia, Andres [2 ]
Llinares, Raul [2 ]
Priego Quesada, Jose Ignacio [1 ,3 ]
Llana-Belloch, Salvador [1 ]
Perez-Soriano, Pedro [1 ]
机构
[1] Univ Valencia, Dept Phys Educ & Sports, Res Grp Sport Biomech GIBD, Valencia, Spain
[2] Univ Politecn Valencia, Alcoy, Spain
[3] Univ Valencia, Dept Physiol, Biophys & Med Phys Grp, Valencia, Spain
来源
PLOS ONE | 2017年 / 12卷 / 02期
关键词
TIBIAL STRESS-FRACTURE; GROUND REACTION FORCE; SHOCK ATTENUATION; LOWER-EXTREMITY; IMPACT FORCES; PERCEIVED EXERTION; MIDSOLE THICKNESS; OVERUSE INJURIES; PLANTAR PRESSURE; STRIKE PATTERN;
D O I
10.1371/journal.pone.0173179
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Each time the foot contacts the ground during running there is a rapid deceleration that results in a shock wave that is transmitted from the foot to the head. The fatigue of the musculoskeletal system during running may decrease the ability of the body to absorb those shock waves and increase the risk of injury. Insoles are commonly prescribed to prevent injuries, and both custom-made and prefabricated insoles have been observed to reduce shock accelerations during running. However, no study to date has included a direct comparison of their behaviour measured over the same group of athletes, and therefore great controversy still exists regarding their effectiveness in reducing impact loading during running. The aim of the study was to analyse the acute differences in stride and shock parameters while running on a treadmill with custom-made and prefabricated insoles. Stride parameters (stride length, stride rate) and shock acceleration parameters (head and tibial peak acceleration, shock magnitude, acceleration rate, and shock attenuation) were measured using two triaxial accelerometers in 38 runners at 3.33 m/s before and after a 15-min intense run while using the sock liner of the shoe (control condition), prefabricated insoles and custom-made insoles. No differences in shock accelerations were found between the custom-made and the control insoles. The prefabricated insoles increased the head acceleration rate (post-fatigue, p = 0.029) compared to the control condition. The custom-made reduced tibial (pre-fatigue, p = 0.041) and head acceleration rates (pre-fatigue and post-fatigue, p = 0.01 and p = 0.046) compared to the prefabricated insoles. Neither the stride nor the acceleration parameters were modified as a result of the intense run. In the present study, the acute use of insoles (custom-made, prefabricated) did not reduce shock accelerations compared to the control insoles. Therefore, their effectiveness at protecting against injuries associated with elevated accelerations is not supported and remains unclear.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Custom-made prosthesis replacement for reconstruction of elbow after tumor resection
    Tang, Xiaodong
    Guo, Wei
    Yang, Rongli
    Tang, Shun
    Yang, Yi
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2009, 18 (05) : 796 - 803
  • [32] Inexpensive custom-made stenting of auditory meatus after stenosis release
    Rodríguez-Vegas, JM
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2005, 116 (03) : 926 - 928
  • [33] Custom-made Prosthesis for Reconstruction after Radical Resection for Chondrosarcoma of Manubrium
    Ma, Xin-long
    Wang, Don-bin
    Ma, Jian-xiong
    Wang, Yin
    Sun, Lei
    Lu, Bin
    Wang, Yan
    Zhao, Xing-wen
    Li, Fei
    Fan, Zheng-rui
    Han, Biao
    Bai, Hao-hao
    Yang, Bao-cheng
    Jiang, Xuan
    Tian, Ai-xian
    Dong, Ben-chao
    Du, Yu-ren
    ORTHOPAEDIC SURGERY, 2018, 10 (03) : 272 - 275
  • [34] Effectiveness of custom-made functional foot orthoses versus flat cushioning insoles on pain in patients with systemic lupus erythematosus
    Palomo-Toucedo, Inmaculada C.
    Dominguez-Maldonado, Gabriel
    Reina-Bueno, Maria
    del Carmen Vazquez-Bautista, Maria
    Manuel Castillo-Lopez, Jose
    Ramos-Ortega, Javier
    Munuera-Martinez, Pedro, V
    CLINICAL REHABILITATION, 2023, 37 (01) : 86 - 97
  • [35] Mechanical complications and infection control comparison of custom-made and prefabricated articular hip spacers in the treatment of periprosthetic infection
    Emmer, Jan
    Tomas, Tomas
    Apostolopoulos, Vasileios
    Brancik, Pavel
    Rapi, Jakub
    Nachtnebl, Lubos
    JOINT DISEASES AND RELATED SURGERY, 2023, 34 (03): : 557 - 564
  • [36] Comparison of Custom-made Versus Prefabricated Thumb Splinting for Carpometacarpal Arthrosis: A Systematic Review and Meta-analysis
    Baradaran, Aslan
    Baradaran, Ashkan
    Ebrahimzadeh, Mohammad H.
    Kachooei, Amir R.
    Rivlin, Michael
    Beredjiklian, Pedro
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2018, 6 (06): : 478 - 485
  • [37] Influence of custom-made and stock mouthguard thickness on biomechanical response to a simulated impact
    Mendes Tribst, Joao Paulo
    de Oliveira Dal Piva, Amanda Maria
    Borges, Alexandre Luiz Souto
    Bottino, Marco Antonio
    DENTAL TRAUMATOLOGY, 2018, 34 (06) : 429 - 437
  • [38] High Rate of Early Revision After Custom-Made Unicondylar Knee Arthroplasty
    Talmo, Carl T.
    Anderson, Marie C.
    Jia, Eliot S.
    Robbins, Claire E.
    Rand, Jason D.
    McKeon, Brian P.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (07): : S100 - S104
  • [39] Custom-made Stent Grafts for the Treatment of Pseudoaneurysms after Childhood Coarctation Surgery
    Lescan, Mario
    Hornung, Andreas
    Hofbeck, Michael
    Schlensak, Christian
    THORACIC AND CARDIOVASCULAR SURGEON, 2019, 67 (01): : 50 - 54
  • [40] Effects of custom-made insoles on foot pressure redistribution, gait parameters, and pain in calcaneal apophysitis-a pretest and posttest study
    Feyzioglu, Ozlem
    Ozturk, Ozgul
    Mugrabi, Selim
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2021, 45 (06) : 532 - 537