Influence of custom-made and prefabricated insoles before and after an intense run

被引:19
|
作者
Gabriel Lucas-Cuevas, Angel [1 ]
Camacho-Garcia, Andres [2 ]
Llinares, Raul [2 ]
Priego Quesada, Jose Ignacio [1 ,3 ]
Llana-Belloch, Salvador [1 ]
Perez-Soriano, Pedro [1 ]
机构
[1] Univ Valencia, Dept Phys Educ & Sports, Res Grp Sport Biomech GIBD, Valencia, Spain
[2] Univ Politecn Valencia, Alcoy, Spain
[3] Univ Valencia, Dept Physiol, Biophys & Med Phys Grp, Valencia, Spain
来源
PLOS ONE | 2017年 / 12卷 / 02期
关键词
TIBIAL STRESS-FRACTURE; GROUND REACTION FORCE; SHOCK ATTENUATION; LOWER-EXTREMITY; IMPACT FORCES; PERCEIVED EXERTION; MIDSOLE THICKNESS; OVERUSE INJURIES; PLANTAR PRESSURE; STRIKE PATTERN;
D O I
10.1371/journal.pone.0173179
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Each time the foot contacts the ground during running there is a rapid deceleration that results in a shock wave that is transmitted from the foot to the head. The fatigue of the musculoskeletal system during running may decrease the ability of the body to absorb those shock waves and increase the risk of injury. Insoles are commonly prescribed to prevent injuries, and both custom-made and prefabricated insoles have been observed to reduce shock accelerations during running. However, no study to date has included a direct comparison of their behaviour measured over the same group of athletes, and therefore great controversy still exists regarding their effectiveness in reducing impact loading during running. The aim of the study was to analyse the acute differences in stride and shock parameters while running on a treadmill with custom-made and prefabricated insoles. Stride parameters (stride length, stride rate) and shock acceleration parameters (head and tibial peak acceleration, shock magnitude, acceleration rate, and shock attenuation) were measured using two triaxial accelerometers in 38 runners at 3.33 m/s before and after a 15-min intense run while using the sock liner of the shoe (control condition), prefabricated insoles and custom-made insoles. No differences in shock accelerations were found between the custom-made and the control insoles. The prefabricated insoles increased the head acceleration rate (post-fatigue, p = 0.029) compared to the control condition. The custom-made reduced tibial (pre-fatigue, p = 0.041) and head acceleration rates (pre-fatigue and post-fatigue, p = 0.01 and p = 0.046) compared to the prefabricated insoles. Neither the stride nor the acceleration parameters were modified as a result of the intense run. In the present study, the acute use of insoles (custom-made, prefabricated) did not reduce shock accelerations compared to the control insoles. Therefore, their effectiveness at protecting against injuries associated with elevated accelerations is not supported and remains unclear.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] An analysis of athletes' knowledge, acceptance and usability toward custom-made mouthguards: uncontrolled before–after study
    Sandra Regina Santos Meyfarth
    Katherine Azevedo Batistela Rodrigues
    Rodrigo Von Held
    Philippe Sarkis
    Luiz Edmundo Costa Gouvea Junior
    Lívia Azeredo Alves Antunes
    Leonardo Santos Antunes
    Sport Sciences for Health, 2023, 19 : 267 - 275
  • [22] Comparison of Prefabricated and Custom-Made Bars Used for Implant-Retained Mandibular Complete Overdentures
    El-Dayem, Mohamed A. Abd
    Assad, Ahmed S.
    Sanad, Mohamed Essam Eldin
    Mogahed, Sayed Abd Al-hady Mahmoud
    IMPLANT DENTISTRY, 2009, 18 (06) : 501 - 511
  • [23] Load-Bearing Capacity of Custom-Made Versus Prefabricated Commercially Available Zirconia Abutments
    Hjerppe, Jenni
    Lassila, Lippo V. J.
    Rakkolainen, Tero
    Narhi, Timo
    Vallittu, Pekka K.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (01) : 132 - 138
  • [24] Fracture resistance of prefabricated versus custom-made zirconia crowns after thermo-mechanical aging: an in-vitro study
    El Shahawy, Osama Ibrahim
    Azab, Maha Moussa
    BMC ORAL HEALTH, 2022, 22 (01)
  • [25] Fracture resistance of prefabricated versus custom-made zirconia crowns after thermo-mechanical aging: an in-vitro study
    Osama Ibrahim El Shahawy
    Maha Moussa Azab
    BMC Oral Health, 22
  • [26] Effects of custom-made textile insoles on plantar pressure distribution and lower limb EMG activity during turning
    W. T. Lo
    D. P. Wong
    K. L. Yick
    S. P. Ng
    J. Yip
    Journal of Foot and Ankle Research, 9
  • [27] Effects of custom-made textile insoles on plantar pressure distribution and lower limb EMG activity during turning
    Lo, W. T.
    Wong, D. P.
    Yick, K. L.
    Ng, S. P.
    Yip, J.
    JOURNAL OF FOOT AND ANKLE RESEARCH, 2016, 9
  • [28] An analysis of athletes' knowledge, acceptance and usability toward custom-made mouthguards: uncontrolled before-after study
    Santos Meyfarth, Sandra Regina
    Batistela Rodrigues, Katherine Azevedo
    Von Held, Rodrigo
    Sarkis, Philippe
    Costa Gouvea Junior, Luiz Edmundo
    Alves Antunes, Livia Azeredo
    Antunes, Leonardo Santos
    SPORT SCIENCES FOR HEALTH, 2023, 19 (01) : 267 - 275
  • [29] Custom-made prefabricated titanium miniplates in Le Fort I osteotomies: principles, procedure and clinical insights
    Philippe, B.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2013, 42 (08) : 1001 - 1006
  • [30] An In-Vitro Investigation into the Fracture Resistance of Prefabricated and Custom-Made Zirconia Crowns for Permanent Molars in Children
    Bani-Hani, Thikrayat
    Al-Fodeh, Rami S.
    Al-Wahadni, Ahed M.
    Abu-Alhaija, Elham S.
    Al-Hakam, Mahmoud
    DENTISTRY JOURNAL, 2025, 13 (02)