The influence of acetabular bone cracks in the press-fit hip replacement: Numerical and experimental analysis

被引:10
|
作者
Ramos, A. [1 ]
Duarte, R. J. [1 ]
Relvas, C. [1 ]
Completo, A. [1 ]
Simoes, J. A. [1 ]
机构
[1] Univ Aveiro, TEMA, Dept Mech Engn, P-3810193 Aveiro, Portugal
关键词
Bone crack; Experimental tests; Finite element analysis; Micromotions; Total hip arthroplasty; FEMUR; CUP; VALIDATION; STABILITY; PATTERNS; PELVIS;
D O I
10.1016/j.clinbiomech.2013.06.005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The press-fit hip acetabular prosthesis implantation can cause crack formation in the thin regions surrounding the acetabular. As a consequence the presence of cracks in this region can lead to poor fixation and fibrous tissue formation. Methods: Numerical and experimental models of commercial press-fit hip replacements were developed to compare the behavior between the intact and implanted joints. Numerical models with an artificial crack and without crack were considered. The iliac and the femur were created through 3D geometry acquisition based on composite human replicas and 3D-Finite Element models were generated. Findings: The mechanical behavior was assessed numerically and experimentally considering the principal strains. The comparison between Finite Element model predictions and experimental measurements revealed a maximum difference of 9%. Similar distribution of the principal strains around the acetabular cavity was obtained for the intact and implanted models. When comparing the Von Mises stresses, it is possible to observe that the intact model is the one that presents the highest stress values in the entire acetabular cavity surface. Interpretation: The crack in the posterior side changes significantly the principal strain distribution, suggesting bone loss after hip replacement Relatively to micromotions, these were higher on the superior side of the acetabular cavity and can change the implant stability and bone ingrowth. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:635 / 641
页数:7
相关论文
共 50 条
  • [41] Initial stability of press-fit acetabular cups - An in-vitro study
    Wetzel, R
    Simnacher, M
    Scheller, G
    [J]. BIOMEDIZINISCHE TECHNIK, 2005, 50 (12): : 400 - 403
  • [42] PRESS-FIT DESIGN IN TOTAL HIP-REPLACEMENT - A COMPARISON BETWEEN THE LUBINUS AND STANMORE PROSTHESES
    BURGAARD, P
    OLSEN, PA
    JENSEN, NM
    ANDERSEN, PB
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1987, 58 (03): : 326 - 326
  • [43] Initial Stability of Press-Fit Acetabular Components Under Rotational Forces
    Fehring, Keith A.
    Owen, John R.
    Kurdin, Anton A.
    Wayne, Jennifer S.
    Jiranek, William A.
    [J]. JOURNAL OF ARTHROPLASTY, 2014, 29 (05): : 1038 - 1042
  • [44] Analysis on cracks of press-fit cylinder blocks in high-pressure piston pumps
    Xu, Liqiang
    Sun, Hongfei
    [J]. JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2019, 41 (11)
  • [45] Experimental analysis of insertion torques and forces of threaded and press-fit acetabular cups by means of ex vivo and in vivo measurements
    Vogel, Danny
    Rathay, Andreas
    Teufel, Stephanie
    Ellenrieder, Martin
    Zietz, Carmen
    Sander, Manuela
    Bader, Rainer
    [J]. ACTA OF BIOENGINEERING AND BIOMECHANICS, 2017, 19 (03) : 155 - 163
  • [46] A novel approach to determine primary stability of acetabular press-fit cups
    Weissmann, Volker
    Boss, Christian
    Bader, Rainer
    Hansmann, Harald
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 80 : 1 - 10
  • [47] A novel method to assess primary stability of press-fit acetabular cups
    Crosnier, Emilie A.
    Keogh, Patrick S.
    Miles, Anthony W.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2014, 228 (11) : 1126 - 1134
  • [48] Analysis on cracks of press-fit cylinder blocks in high-pressure piston pumps
    Liqiang Xu
    Hongfei Sun
    [J]. Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2019, 41
  • [49] Limitation of total hip arthroplasty of the acetabular roof by press-fit without screw fixation: Discussion of a biomechanical study
    Kanda A.
    Kaneko K.
    Obayashi O.
    Mogami A.
    Iwase H.
    [J]. European Journal of Orthopaedic Surgery & Traumatology, 2013, 23 (4) : 417 - 424
  • [50] Incomplete seating of press-fit porous-coated acetabular components
    Springer, Bryan D.
    Griffin, William L.
    Fehring, Thomas K.
    Suarez, Juan
    Odum, Susan
    Thompson, Caryn
    [J]. JOURNAL OF ARTHROPLASTY, 2008, 23 (06): : 121 - 126