The influence of acetabular bone cracks in the press-fit hip replacement: Numerical and experimental analysis

被引:10
|
作者
Ramos, A. [1 ]
Duarte, R. J. [1 ]
Relvas, C. [1 ]
Completo, A. [1 ]
Simoes, J. A. [1 ]
机构
[1] Univ Aveiro, TEMA, Dept Mech Engn, P-3810193 Aveiro, Portugal
关键词
Bone crack; Experimental tests; Finite element analysis; Micromotions; Total hip arthroplasty; FEMUR; CUP; VALIDATION; STABILITY; PATTERNS; PELVIS;
D O I
10.1016/j.clinbiomech.2013.06.005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The press-fit hip acetabular prosthesis implantation can cause crack formation in the thin regions surrounding the acetabular. As a consequence the presence of cracks in this region can lead to poor fixation and fibrous tissue formation. Methods: Numerical and experimental models of commercial press-fit hip replacements were developed to compare the behavior between the intact and implanted joints. Numerical models with an artificial crack and without crack were considered. The iliac and the femur were created through 3D geometry acquisition based on composite human replicas and 3D-Finite Element models were generated. Findings: The mechanical behavior was assessed numerically and experimentally considering the principal strains. The comparison between Finite Element model predictions and experimental measurements revealed a maximum difference of 9%. Similar distribution of the principal strains around the acetabular cavity was obtained for the intact and implanted models. When comparing the Von Mises stresses, it is possible to observe that the intact model is the one that presents the highest stress values in the entire acetabular cavity surface. Interpretation: The crack in the posterior side changes significantly the principal strain distribution, suggesting bone loss after hip replacement Relatively to micromotions, these were higher on the superior side of the acetabular cavity and can change the implant stability and bone ingrowth. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:635 / 641
页数:7
相关论文
共 50 条
  • [31] Complications of porous-coated press-fit cementless total hip replacement in dogs
    Kidd, Scott W.
    Preston, Christopher A.
    Moore, George E.
    [J]. VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2016, 29 (05) : 402 - 408
  • [32] Treatment Outcomes for Periprosthetic Femoral Fractures in Cementless Press-Fit Total Hip Replacement
    Monotti, Isobel C.
    Preston, Christopher A.
    Kidd, Scott W.
    [J]. VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2020, 33 (05) : 370 - 376
  • [33] Load transfer and fixation mode of press-fit acetabular sockets
    Widmer, KH
    Zurfluh, B
    Morscher, EW
    [J]. JOURNAL OF ARTHROPLASTY, 2002, 17 (07): : 926 - 935
  • [34] Influence of trabecular bone quality and implantation direction on press-fit mechanics
    Damm, Niklas B.
    Morlock, Michael M.
    Bishop, Nicholas E.
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2017, 35 (02) : 224 - 233
  • [35] Press-fit analysis of multilayer interference fit
    Wang, Xingyuan
    Wang, Yue
    Zhang, Lixun
    Lou, Zhifeng
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2023, 237 (04) : 903 - 918
  • [36] Determination of the initial stability of press-fit acetabular components using a new acetabular reamer
    Hofmeister, V
    Pitto, RP
    Schramm, M
    [J]. BIOMEDIZINISCHE TECHNIK, 1999, 44 (12): : 352 - 355
  • [37] Host bone coverage requirements for press-fit acetabular cup fixation. 3D-CT analysis
    Takao, M
    Sugano, N
    Nishii, T
    Miki, H
    Koyama, T
    Yoshikawa, H
    [J]. CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 1299 - 1299
  • [38] Finite element analysis of shear stresses at the implant-bone interface of an acetabular press-fit cup during impingement
    Voigt, Christian
    Kloehn, Carsten
    Bader, Rainer
    von Salis-Soglio, Georg
    Scholz, Roger
    [J]. BIOMEDIZINISCHE TECHNIK, 2007, 52 (02): : 208 - 215
  • [39] AN INVESTIGATION OF A COMPLIANT INTERFACE FOR PRESS-FIT JOINT REPLACEMENT
    WALKER, PS
    RODGER, RF
    MIEGEL, RE
    SCHILLER, AL
    DELAND, JT
    ROBERTSON, DD
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1990, 8 (03) : 453 - 463
  • [40] Effect of cup medialization on primary stability of press-fit acetabular cups
    Morosato, Federico
    Cristofolini, Luca
    Castagnini, Francesco
    Traina, Francesco