Load transfer and fixation mode of press-fit acetabular sockets

被引:91
|
作者
Widmer, KH [1 ]
Zurfluh, B
Morscher, EW
机构
[1] Kantonsppital Bruderholz, Dept Orthoped Surg & Traumatol, CH-4101 Bruderholz, Switzerland
[2] Felix Platter Hosp, Orthopaed Biomech Lab, Basel, Switzerland
来源
JOURNAL OF ARTHROPLASTY | 2002年 / 17卷 / 07期
关键词
peripheral load transfer; press-fit fixation; contact area; 3-point support; physiologic load transmission;
D O I
10.1054/arth.2002.34526
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Adequate initial fixation is a prerequisite for osseointegration and secondary stability of noncemented cups. Physiologic force transmission between the cup and acetabulum guarantees the best long-term fixation. To study load transfer within the natural hip joint and in the bone-implant interface of 2 different hemispherical noncemented press-fit cups, 10 hips were investigated in an experimental setup simulating single-leg stance. Load distribution and contact area were measured using prescale pressure-sensitive films and digital image analysis. Three dominant locations near the periphery of the acetabulum could be identified. Main load transfer occurs in the cranial region of the acetabulum, where it is buttressed by the iliac bone; the second location is at the posterior-inferior region at the ischial facet, and the third location is at the anterior region, where support is provided by the pubic bone. Peripheral rim contact was present in both cups but not completely circumferential. It showed marked loading at the same 3 locations similar to the natural hip joint. The ilioischial diagonal axis produced the highest press-fit. Peak local forces were found at the ischial and iliac facets. Local forces can be grouped into an iliac, an ischial, and a pubic group contributing 55%, 25%, and 20% to the total hip joint force. Pole contact was not present in the natural hip and with the biradial press-fit cup with flattened pole area but was observed with the pure hemispherical cup. Hence, stable fixation of an acetabular cup is achieved best by a 3-point-like bony support at the iliac, ischial, and pubic bone. The acetabular fovea does riot provide functional support of the femoral head or endoprosthetic socket. In revision surgery, remaining peripheral bone stock at the iliac, ischial, and pubic locations allows stable implanation of primary cups.
引用
收藏
页码:926 / 935
页数:10
相关论文
共 50 条
  • [1] Acetabular component deformation with press-fit fixation
    Squire, Matthew
    Griffin, William L.
    Mason, Bohannon
    Peindl, Richard D.
    Odum, Susan
    [J]. JOURNAL OF ARTHROPLASTY, 2006, 21 (06): : 72 - 77
  • [2] Press-fit cementless acetabular fixation with and without screws
    Ni, Sheng-Hui
    Guo, Lei
    Jiang, Tian-Long
    Zhao, Jie
    Zhao, Yan-Gang
    [J]. INTERNATIONAL ORTHOPAEDICS, 2014, 38 (01) : 7 - 12
  • [3] Press-fit cementless acetabular fixation with and without screws
    Sheng-Hui Ni
    Lei Guo
    Tian-Long Jiang
    Jie Zhao
    Yan-Gang Zhao
    [J]. International Orthopaedics, 2014, 38 : 7 - 12
  • [4] Press-fit acetabular cup fixation: principles and testing
    Macdonald, W
    Carlsson, LV
    Charnley, GJ
    Jacobsson, CM
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H1) : 33 - 39
  • [5] Acetabular Cup Seating Impact Sensing for Press-Fit Acetabular Cup Fixation
    Tang, L.
    Tennant, J. K.
    Forster, A.
    Reddy, M.
    [J]. 2016 12TH IEEE/ASME INTERNATIONAL CONFERENCE ON MECHATRONIC AND EMBEDDED SYSTEMS AND APPLICATIONS (MESA), 2016,
  • [6] STABILITY OF PRESS-FIT ACETABULAR CUPS
    KUMMER, FJ
    STUCHIN, SA
    ADLER, A
    [J]. BULLETIN OF THE HOSPITAL FOR JOINT DISEASES ORTHOPAEDIC INSTITUTE, 1991, 51 (01): : 116 - 116
  • [7] The initial fixation of the press-fit acetabular shell – clinical observation and experimental study
    K. Kaneko
    Yukio Inoue
    Yasushi Yanagihara
    Souichi Uta
    Atsuhiko Mogami
    Hideaki Iwase
    [J]. Archives of Orthopaedic and Trauma Surgery, 2000, 120 : 323 - 325
  • [8] FACTORS THAT INFLUENCE BONE-INGROWTH FIXATION OF PRESS-FIT ACETABULAR CUPS
    Wiznia, Daniel H.
    Schwarzkopf, Ran
    Iorio, Richard
    Long, William J.
    [J]. JBJS REVIEWS, 2019, 7 (06)
  • [9] Reamed surface topography and component seating in press-fit cementless acetabular fixation
    Kim, YS
    Brown, TD
    Pedersen, DR
    Callaghan, JJ
    [J]. JOURNAL OF ARTHROPLASTY, 1995, 10 : S14 - S21
  • [10] The initial fixation of the press-fit acetabular shell - clinical observation and experimental study
    Kaneko, K
    Inoue, Y
    Yanagihara, Y
    Uta, S
    Mogami, A
    Iwase, H
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2000, 120 (5-6) : 323 - 325