Acetabular Cup Seating Impact Sensing for Press-Fit Acetabular Cup Fixation

被引:0
|
作者
Tang, L. [1 ]
Tennant, J. K. [1 ]
Forster, A. [2 ]
Reddy, M. [2 ]
机构
[1] Massey Univ, Palmerston North, New Zealand
[2] Palmerston North Hosp, Palmerston North, New Zealand
关键词
acetabular cup fixation; impact sensing; wireless data processing; DEFORMATION; INSERTION;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Total Hip Arthroplasty (THA) is an excellent and reliable pain relieving operation which improves the function and quality of life for patients disabled by osteoarthritis [1]. Non-cemented hemispherical acetabular cup implants are now popular and accepted by surgeons world-wide [2]. In surgery, the acetabular cup is impacted into the native acetabulum with a cup impactor and hand-held mallets. Surgeons rely on multiple impacts to achieve the satisfactory stability and fully seat the implant [3]. The impacts on cup impactors greatly affect the quality of the surgery. Quantifying the load-transfer at the bone-implant interface and the understanding of the distribution pattern [2] is essential to determine the optimal force range that can satisfactorily seat the hemispherical acetabular cup to achieve mechanical stability without causing potential damage to surrounding tissue. This paper presents a novel acetabular cup seating impact capturing system that quantifies and records the dynamic impacts applied on an acetabular cup by surgeons using a cup impactor with different sized mallets. The system is an integrated mechatronics system. It consists of three modules: microcontroller-based sensing, wireless communication and PC-based data acquisition. The system is designed as an add-on unit to the cup impactor. Laboratory-based preliminary testing was performed on the system by surgeons using synthetic polyurethane left hemipelvis saw bones. Dynamic impacts applied on a non-cemented hemispherical acetabular cup were captured, recorded and wirelessly transferred to a computer in real time.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Press-fit acetabular cup fixation: principles and testing
    Macdonald, W
    Carlsson, LV
    Charnley, GJ
    Jacobsson, CM
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H1) : 33 - 39
  • [2] Acetabular revision in total hip replacement with a press-fit cup
    Elke, R
    Berli, B
    Wagner, A
    Morscher, EW
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (08): : 1114 - 1119
  • [3] Effect of cup medialization on primary stability of press-fit acetabular cups
    Morosato, Federico
    Cristofolini, Luca
    Castagnini, Francesco
    Traina, Francesco
    [J]. CLINICAL BIOMECHANICS, 2020, 80
  • [4] Monitoring the press-fit insertion of an acetabular cup by impact measurements: Influence of bone abrasion
    Michel, Adrien
    Bosc, Romain
    Mathieu, Vincent
    Hernigou, Philippe
    Haiat, Guillaume
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2014, 228 (10) : 1027 - 1034
  • [5] Effect of cementless acetabular cup geometry on strain distribution and press-fit stability
    Ries, MD
    Harbaugh, M
    Shea, J
    Lambert, R
    [J]. JOURNAL OF ARTHROPLASTY, 1997, 12 (02): : 207 - 212
  • [6] Reamed surface topography and component seating in press-fit cementless acetabular fixation
    Kim, YS
    Brown, TD
    Pedersen, DR
    Callaghan, JJ
    [J]. JOURNAL OF ARTHROPLASTY, 1995, 10 : S14 - S21
  • [7] Acetabular component deformation with press-fit fixation
    Squire, Matthew
    Griffin, William L.
    Mason, Bohannon
    Peindl, Richard D.
    Odum, Susan
    [J]. JOURNAL OF ARTHROPLASTY, 2006, 21 (06): : 72 - 77
  • [8] Acetabular revision of total hip arthroplasty using a press-fit dual mobility cup
    Massin, P.
    Besnier, L.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2010, 96 (01) : 8 - 12
  • [9] Advanced material modelling in numerical simulation of primary acetabular press-fit cup stability
    Souffrant, R.
    Zietz, C.
    Fritsche, A.
    Kluess, D.
    Mittelmeier, W.
    Bader, R.
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2012, 15 (08) : 787 - 793
  • [10] Primary stability of a press-fit cup in combination with impaction grafting in an acetabular defect model
    Schierjott, Ronja A.
    Hettich, Georg
    Baxmann, Marc
    Morosato, Federico
    Cristofolini, Luca
    Grupp, Thomas M.
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2021, 39 (05) : 929 - 940