Acetabular Cup Seating Impact Sensing for Press-Fit Acetabular Cup Fixation

被引:0
|
作者
Tang, L. [1 ]
Tennant, J. K. [1 ]
Forster, A. [2 ]
Reddy, M. [2 ]
机构
[1] Massey Univ, Palmerston North, New Zealand
[2] Palmerston North Hosp, Palmerston North, New Zealand
关键词
acetabular cup fixation; impact sensing; wireless data processing; DEFORMATION; INSERTION;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Total Hip Arthroplasty (THA) is an excellent and reliable pain relieving operation which improves the function and quality of life for patients disabled by osteoarthritis [1]. Non-cemented hemispherical acetabular cup implants are now popular and accepted by surgeons world-wide [2]. In surgery, the acetabular cup is impacted into the native acetabulum with a cup impactor and hand-held mallets. Surgeons rely on multiple impacts to achieve the satisfactory stability and fully seat the implant [3]. The impacts on cup impactors greatly affect the quality of the surgery. Quantifying the load-transfer at the bone-implant interface and the understanding of the distribution pattern [2] is essential to determine the optimal force range that can satisfactorily seat the hemispherical acetabular cup to achieve mechanical stability without causing potential damage to surrounding tissue. This paper presents a novel acetabular cup seating impact capturing system that quantifies and records the dynamic impacts applied on an acetabular cup by surgeons using a cup impactor with different sized mallets. The system is an integrated mechatronics system. It consists of three modules: microcontroller-based sensing, wireless communication and PC-based data acquisition. The system is designed as an add-on unit to the cup impactor. Laboratory-based preliminary testing was performed on the system by surgeons using synthetic polyurethane left hemipelvis saw bones. Dynamic impacts applied on a non-cemented hemispherical acetabular cup were captured, recorded and wirelessly transferred to a computer in real time.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Interfacial conditions between a press-fit acetabular cup and bone during daily activities: implications for achieving bone in-growth
    Spears, IR
    Pfleiderer, M
    Schneider, E
    Hille, E
    Bergmann, G
    Morlock, MM
    [J]. JOURNAL OF BIOMECHANICS, 2000, 33 (11) : 1471 - 1477
  • [32] Cup Press Fit in Uncemented THA Depends on Sex, Acetabular Shape, and Surgical Technique
    Garcia-Rey, Eduardo
    Garcia-Cimbrelo, Eduardo
    Cruz-Pardos, Ana
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (11) : 3014 - 3023
  • [33] Acetabular cup replacement
    Reichel, H.
    Fuchs, M.
    [J]. ORTHOPADE, 2021, 50 (10): : 832 - 834
  • [34] Late loosening of press-fit cementless acetabular components
    Jiranek, WA
    Whiddon, DR
    Johnstone, WT
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (418) : 172 - 178
  • [35] Deformation characteristics and eigenfrequencies of press-fit acetabular cups
    Hothan, Arne
    Huber, Gerd
    Weiss, Cornelius
    Hoffmann, Norbert
    Morlock, Michael
    [J]. CLINICAL BIOMECHANICS, 2011, 26 (01) : 46 - 51
  • [36] Determination of the initial stability of press-fit acetabular components using a new acetabular reamer
    Hofmeister, V
    Pitto, RP
    Schramm, M
    [J]. BIOMEDIZINISCHE TECHNIK, 1999, 44 (12): : 352 - 355
  • [37] The Relation between micromotion and Screw Fixation in Acetabular Cup
    Hsu, Jui-Ting
    Lai, Kuo-An
    Chen, Qingshan
    Zobitz, Mark E.
    Huang, Heng-Li
    An, Kai-Nan
    Chang, Chih-Han
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2006, 84 (01) : 34 - 41
  • [38] Risk factors for unsuccessful acetabular press-fit fixation at primary total hip arthroplasty
    Brulc, U.
    Antolic, V.
    Mavcic, B.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (07) : 993 - 997
  • [39] Prediction of intraoperative press-fit stability of the acetabular cup in total hip arthroplasty using radiomics-based machine learning models
    He, Bin
    Zhang, Xin
    Peng, Shengwang
    Zeng, Dong
    Chen, Haicong
    Liang, Zhenming
    Zhong, Huan
    Ouyang, Hanbin
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2024, 181
  • [40] Minimum 20-year follow-up of a press-fit acetabular cup in cementless total hip replacement in young patients
    Lunz, Andre
    Von Falkenhayn, Moritz
    Jaeger, Sebastian
    Reiner, Tobias
    Merle, Christian
    Streit, Marcus R.
    Renkawitz, Tobias
    Innmann, Moritz M.
    [J]. ACTA ORTHOPAEDICA, 2023, 94 : 321 - 327