Body composition: validity of segmental bioelectrical impedance analysis

被引:0
|
作者
LaForgia, Joe [2 ]
Gunn, Simon M. [1 ]
Withers, Robert T. [1 ]
机构
[1] Flinders Univ S Australia, Sch Educ, Exercise Physiol Lab, Adelaide, SA 5001, Australia
[2] Univ S Australia, Sch Pharm & Med Sci, Adelaide, SA 5001, Australia
基金
英国医学研究理事会;
关键词
total body water; percent body fat; foot-to-foot BIA; four-compartment body composition model; fat free mass;
D O I
暂无
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Bioelectrical impedance analysis (BIA) measures the impedance associated with passage of an alternating current through the body which is proportional to total body water (TBW) and therefore can provide expedient estimates of body composition. However, little validity information is available for commercially available bathroom scale type devices which perform whole body estimates from segmental (lower limb) measurements. This study therefore compared body composition estimates between a commercially available segmental BIA device (Tanita BC-532) and four compartment criterion values. Body composition of nine males and nine females (mean +/- SD: 37.7 +/- 18.7 yr; 170.7 +/- 5.3 cm; 68.38 +/- 9.7 kg) was determined via BIA and a four compartment model incorporating measures of body density, TBW and bone mineral mass. While the mean %BF and fat free mass (FFM) values for both methods were not significantly different, considerable intra-individual differences were observed. BIA values varied from the four compartment values by -3.0 to 4.4 %BF and -3.3 to 1.9 kg FFM. The BIA estimates of TBW were significantly different from the criterion measures and intra-individual differences displayed a large range (-0.6 to 3.6 kg). Significant underestimations of TBW via BIA are concerning given that this is the parameter initially established by this method. Furthermore, the BIA data resulted in a FFM hydration value of 68.5% which was significantly (p < 0.001) lower than the four compartment value of 72.0%. In conclusion, the BIA device tested displayed poor individual accuracy for the estimation of body composition compared with a four compartment criterion method.
引用
下载
收藏
页码:586 / 591
页数:6
相关论文
共 50 条
  • [31] BIOELECTRICAL IMPEDANCE AND BODY-COMPOSITION
    不详
    LANCET, 1992, 340 (8834-5): : 1511 - 1511
  • [32] Bioelectrical impedance analysis for predicting body composition: what about the external validity of new regression equations?
    Trippo, U
    Koebnick, C
    Zunft, HJF
    Greil, H
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 2004, 79 (02): : 335 - 336
  • [33] The reproducibility and validity verification for body composition measuring devices using bioelectrical impedance analysis in Korean adults
    Yang, Seung-Won
    Kim, Tai-Hyung
    Choi, Hyun-Min
    JOURNAL OF EXERCISE REHABILITATION, 2018, 14 (04) : 621 - 627
  • [34] BIOELECTRICAL IMPEDANCE ANALYSIS AS A METHOD TO ASSESS BODY-COMPOSITION
    LAWLOR, MR
    CRISMAN, RP
    HODGDON, JA
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1985, 17 (02): : 271 - 272
  • [35] Qualitative human body composition analysis assessed with bioelectrical impedance
    Talluri, T
    COLLEGIUM ANTROPOLOGICUM, 1998, 22 (02) : 427 - 432
  • [36] The use of bioelectrical impedance analysis for body composition in epidemiological studies
    A Böhm
    B L Heitmann
    European Journal of Clinical Nutrition, 2013, 67 : S79 - S85
  • [37] Evaluation of bioelectrical impedance analysis as an estimator of moose body composition
    Hundertmark, KJ
    Schwartz, CC
    WILDLIFE SOCIETY BULLETIN, 2002, 30 (03) : 915 - 921
  • [38] Body composition by bioelectrical impedance analysis in renal transplant recipients
    Wong, HS
    Boey, LM
    Morad, Z
    TRANSPLANTATION PROCEEDINGS, 2004, 36 (07) : 2186 - 2187
  • [39] Multifrequency bioelectrical impedance analysis to assess human body composition
    Islam, S
    Kabir, I
    Wahed, MA
    Goran, MI
    Mahalanabis, D
    Fuchs, GJ
    Khaled, MA
    NUTRITION RESEARCH, 1999, 19 (08) : 1179 - 1188
  • [40] MEASUREMENT OF BODY-COMPOSITION USING BIOELECTRICAL IMPEDANCE ANALYSIS
    LUBANSKI, RE
    KURZER, M
    MEGUID, MM
    CLINICAL RESEARCH, 1987, 35 (03): : A775 - A775