Multifrequency bioelectrical impedance analysis to assess human body composition

被引:3
|
作者
Islam, S
Kabir, I
Wahed, MA
Goran, MI
Mahalanabis, D
Fuchs, GJ
Khaled, MA
机构
[1] ICDDR B, Div Clin Sci, Dhaka 1000, Bangladesh
[2] Univ Alabama Birmingham, Dept Nutr Sci, Birmingham, AL 35294 USA
基金
美国国家卫生研究院;
关键词
impedance; frequency; total body water; extracellular water; intracellular water;
D O I
10.1016/S0271-5317(99)00079-2
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Multifrequency bioelectrical impedance analysis (MF-BIA) was validated as a method to predict total body water (TBW), extracellular water (ECW), fat free mass (FFM) and fat mass (FM) with other laboratory based methods. Twenty-two healthy adult male volunteers were selected from the staffs of International Centre for Diarrhoeal Disease Research, Bangladesh (ICDDR,B). Ten mL of deuterium oxide (D2O) along with 1 mL/Kg of 3 g% NaBr solution were given orally to each subject. In order to validate the method, deuterium- and bromide-dilution principles were utilized by using isotope-ratio mass spectrophotometer (IRMS), high performance liquid chromatography (HPLC) and spectrophotometer (SP). Data obtained by these methods were compared to assess the accuracy between the methods. The mean+/-SD BMI was 24.2+/-1.7 which indicates that the volunteers were not obese or overweight anthrapometrically. A significant correlation of TEW was observed between MF-BIA and IRMS techniques (r(2) = 0.44, p<0.001). However, the ECW volume was 7% higher by MF-BIA and 2% by HPLC in relation to the D2O dilution method whereas SP method gave the most accurate volume of ECW. The findings of the study indicate that MF-BIA method overestimated ECW although TBW by MF-BIA and IRMS correlated well. The co-efficient of variation (CV%) of ECW measured by HPLC was 9% and by SP method was 27%, indicating that ECW measured by HPLC was more accurate. In summary it could be concluded that MF-BIA is a rapid and useful technique to assess the body composition and its usefulness could be increased if ECW measurement by this method is improved further. (C) 1999 Elsevier Science Inc.
引用
收藏
页码:1179 / 1188
页数:10
相关论文
共 50 条
  • [1] Multifrequency bioelectrical impedance analysis (BIA) to assess human body composition.
    Islam, S
    Kabir, I
    Wahed, MA
    Goran, MI
    Mahalanabis, D
    Fuchs, GJ
    Khaled, MA
    [J]. FASEB JOURNAL, 1997, 11 (03): : 3759 - 3759
  • [2] Evaluation of Multifrequency Bioelectrical Impedance Analysis in Assessing Body Composition of Wrestlers
    Utter, Alan C.
    Lambeth, Pamela G.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2010, 42 (02): : 361 - 367
  • [3] USE OF BIOELECTRICAL IMPEDANCE ANALYSIS TO ASSESS HUMAN-BODY COMPOSITION - A REVIEW
    LUKASKI, HC
    [J]. NUTRITIONAL STATUS ASSESSMENT OF THE INDIVIDUAL, 1989, : 189 - 204
  • [4] Does multifrequency bioelectrical impedance relate to body composition?
    Suzuki, H
    Rounds, JD
    Wilmore, DM
    [J]. JOURNAL OF SURGICAL RESEARCH, 1996, 65 (01) : 63 - 69
  • [5] BIOELECTRICAL IMPEDANCE ANALYSIS AS A METHOD TO ASSESS BODY-COMPOSITION
    LAWLOR, MR
    CRISMAN, RP
    HODGDON, JA
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1985, 17 (02): : 271 - 272
  • [6] Evaluation of body composition in COPD patients using multifrequency bioelectrical impedance analysis
    de Blasio, Francesca
    de Blasio, Francesco
    Berlingieri, Giulia Miracco
    Bianco, Andrea
    La Greca, Marta
    Franssen, Frits M. E.
    Scalfi, Luca
    [J]. INTERNATIONAL JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2016, 11 : 2419 - 2426
  • [7] Early embryo development in terms of body composition by multifrequency bioelectrical impedance analysis
    Kobayashi, M.
    Yoshida, A.
    Koyama, S.
    Yoshie, M.
    Jwa, J.
    Tanaka, M.
    [J]. HUMAN REPRODUCTION, 2014, 29 : 230 - 231
  • [8] Postoperative Changes in Body Composition After Pancreaticoduodenectomy Using Multifrequency Bioelectrical Impedance Analysis
    Mikamori, Manabu
    Miyamoto, Atsushi
    Asaoka, Tadafumi
    Maeda, Sakae
    Hama, Naoki
    Yamamoto, Kazuyoshi
    Hirao, Motohiro
    Ikeda, Masataka
    Sekimoto, Mitsugu
    Doki, Yuichiro
    Mori, Masaki
    Nakamori, Shoji
    [J]. JOURNAL OF GASTROINTESTINAL SURGERY, 2016, 20 (03) : 611 - 618
  • [9] Postoperative Changes in Body Composition After Pancreaticoduodenectomy Using Multifrequency Bioelectrical Impedance Analysis
    Manabu Mikamori
    Atsushi Miyamoto
    Tadafumi Asaoka
    Sakae Maeda
    Naoki Hama
    Kazuyoshi Yamamoto
    Motohiro Hirao
    Masataka Ikeda
    Mitsugu Sekimoto
    Yuichiro Doki
    Masaki Mori
    Shoji Nakamori
    [J]. Journal of Gastrointestinal Surgery, 2016, 20 : 611 - 618
  • [10] VALIDATION OF TETRAPOLAR BIOELECTRICAL IMPEDANCE METHOD TO ASSESS HUMAN-BODY COMPOSITION
    LUKASKI, HC
    BOLONCHUK, WW
    HALL, CB
    SIDERS, WA
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1986, 60 (04) : 1327 - 1332