Body composition: validity of segmental bioelectrical impedance analysis

被引:0
|
作者
LaForgia, Joe [2 ]
Gunn, Simon M. [1 ]
Withers, Robert T. [1 ]
机构
[1] Flinders Univ S Australia, Sch Educ, Exercise Physiol Lab, Adelaide, SA 5001, Australia
[2] Univ S Australia, Sch Pharm & Med Sci, Adelaide, SA 5001, Australia
基金
英国医学研究理事会;
关键词
total body water; percent body fat; foot-to-foot BIA; four-compartment body composition model; fat free mass;
D O I
暂无
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Bioelectrical impedance analysis (BIA) measures the impedance associated with passage of an alternating current through the body which is proportional to total body water (TBW) and therefore can provide expedient estimates of body composition. However, little validity information is available for commercially available bathroom scale type devices which perform whole body estimates from segmental (lower limb) measurements. This study therefore compared body composition estimates between a commercially available segmental BIA device (Tanita BC-532) and four compartment criterion values. Body composition of nine males and nine females (mean +/- SD: 37.7 +/- 18.7 yr; 170.7 +/- 5.3 cm; 68.38 +/- 9.7 kg) was determined via BIA and a four compartment model incorporating measures of body density, TBW and bone mineral mass. While the mean %BF and fat free mass (FFM) values for both methods were not significantly different, considerable intra-individual differences were observed. BIA values varied from the four compartment values by -3.0 to 4.4 %BF and -3.3 to 1.9 kg FFM. The BIA estimates of TBW were significantly different from the criterion measures and intra-individual differences displayed a large range (-0.6 to 3.6 kg). Significant underestimations of TBW via BIA are concerning given that this is the parameter initially established by this method. Furthermore, the BIA data resulted in a FFM hydration value of 68.5% which was significantly (p < 0.001) lower than the four compartment value of 72.0%. In conclusion, the BIA device tested displayed poor individual accuracy for the estimation of body composition compared with a four compartment criterion method.
引用
下载
收藏
页码:586 / 591
页数:6
相关论文
共 50 条
  • [41] Body composition of young laborers:: The results of a bioelectrical impedance analysis
    Ozener, Baris
    Duyar, Izzet
    Atamturk, Derya
    COLLEGIUM ANTROPOLOGICUM, 2007, 31 (04) : 949 - 954
  • [42] MEASUREMENT OF BODY-COMPOSITION USING BIOELECTRICAL IMPEDANCE ANALYSIS
    LUBANSKI, RE
    KURZER, M
    MEGUID, MM
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1987, 45 (04): : 830 - 830
  • [43] Applications of bioelectrical impedance analysis for body composition to epidemiologic studies
    Roubenoff, R
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1996, 64 (03): : 459 - 462
  • [44] Assessment of body composition in elderly:: Accuracy of bioelectrical impedance analysis
    Bussolotto, M
    Ceccon, A
    Sergi, G
    Giantin, V
    Benincà, P
    Enzi, G
    GERONTOLOGY, 1999, 45 (01) : 39 - 43
  • [45] The use of bioelectrical impedance analysis for body composition in epidemiological studies
    Bohm, A.
    Heitmann, B. L.
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2013, 67 : S79 - S85
  • [46] Bioelectrical impedance: The effect of exercise on bioelectrical impedance measurement and calculation of body composition
    Civar, S
    Ozer, K
    Gursel, E
    RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 2006, 77 (01) : A37 - A38
  • [47] A COMPARISON OF TWO SEGMENTAL BIOELECTRICAL IMPEDANCE ANALYSIS METHODS WITH WHOLE-BODY ANALYSIS
    Cannon, Thomas
    Choi, JungHun
    2019 DESIGN OF MEDICAL DEVICES CONFERENCE, 2019,
  • [48] Clinical usefulness of segmental bioelectrical impedance analysis
    Sakamoto, Y
    Sakamoto, N
    Ikeda, Y
    Nishizawa, M
    Heymsfield, SB
    OBESITY RESEARCH, 2000, 8 : 111S - 111S
  • [49] Urine Specific Gravity Effect on Total and Segmental Body Composition Validity of Multifrequency Bioelectrical Impedance Analysis Compared With Dual Energy X-Ray Absorptiometry
    Fleck, Steven J.
    Hayes, Alexa
    Stadler, Garrett
    Goesch, Tucker
    Goldammer, Morgan
    Braun, Saori
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2021, 35 (02) : 373 - 384
  • [50] Body mass index, bioelectrical impedance, and body composition
    Lukaski, HC
    NUTRITION, 2001, 17 (01) : 55 - 56