Clinical Efficacy of Electronic Apex Locators: Systematic Review

被引:60
|
作者
Martins, Jorge N. R. [1 ,2 ,3 ]
Marques, Duarte [1 ,4 ,5 ]
Mata, Antonio [1 ,4 ,6 ]
Carames, Joao [1 ,5 ]
机构
[1] Univ Lisbon, Sch Dent Med, P-1699 Lisbon, Portugal
[2] NYU, Coll Dent, Inter PG Endodont, New York, NY USA
[3] Implantol Inst, Dept Endodont, Lisbon, Portugal
[4] Univ Lisbon, Evidence Based Dent Ctr, Oral Biol & Biochem Grp, Biomed & Oral Sci Res Unit,FCT Unit 4062, P-1699 Lisbon, Portugal
[5] Implantol Inst, Lisbon, Portugal
[6] NYU, Coll Dent, New York, NY USA
关键词
Electric impedance; electronics; odontometry; radiography; WORKING LENGTH DETERMINATION; ROOT-CANAL LENGTH; IN-VIVO EVALUATION; ENDODONTIC TREATMENT; POSTERIOR TEETH; TOOTH LENGTH; PART; ACCURACY; ZX; RADIOGRAPHS;
D O I
10.1016/j.joen.2014.03.011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: Apical constriction has been proposed as the most appropriate apical limit for the endodontic working length. Despite being the most used, some limitations are attributed to the radiographic method of working length determination. It lacks precision because it is based on the average position of the apical constriction. The electronic apex locators have been presented as an alternative to the odontometry performed by radiography. These devices detect the transition of the pulp to the periodontal tissue, which is anatomically very close to the apical constriction and may perform with improved accuracy. Methods: A systematic review was performed to compare the radiographic and electronic methods. Clinical studies that compared both methods were searched for on 7 electronic databases, a manual search was,performed on the bibliography of articles collected on the electronic databases, and the authors were contacted to ask for references of more research not detected on the electronic and manual search. Results: Twenty-one articles were selected. The majority were comparative or evaluation studies, and very few clinical studies comparing both methods are available. Several methodological limitations are present on the collected articles and debated in this review. Conclusions: Although the available scientific evidence base is short and at considerable risk of bias, it is still possible to conclude that the apical locator reduces the patient radiation exposure and also that the electronic method may perform better on the working length determination. At least one radiographic control should be performed to detect possible errors of the electronic devices.
引用
收藏
页码:759 / 777
页数:19
相关论文
共 50 条
  • [22] Interference of Electronic Apex Locators with Implantable Cardioverter Defibrillators
    Idzahi, Karim
    de Cock, Carel C.
    Shemesh, Hagay
    Brand, Henk S.
    [J]. JOURNAL OF ENDODONTICS, 2014, 40 (02) : 277 - 280
  • [23] Determination of location of root perforations by electronic apex locators
    Fuss, Z
    Assooline, LS
    Kaufman, AY
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1996, 82 (03): : 324 - 329
  • [24] Comparison of two electronic apex locators on human cadavers
    Marigo, Luca
    Gervasi, Gian Luca
    Somma, Francesco
    Squeo, Giuseppe
    Castagnola, Raffaella
    [J]. CLINICAL ORAL INVESTIGATIONS, 2016, 20 (07) : 1547 - 1550
  • [25] An improved model for teaching use of electronic apex locators
    Tchorz, J. P.
    Hellwig, E.
    Altenburger, M. J.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2012, 45 (04) : 307 - 310
  • [26] Accuracy of two electronic apex locators in primary teeth
    Bolan, Michele
    de Carvalho Rocha, Maria Jose
    [J]. ENDO-ENDODONTIC PRACTICE TODAY, 2010, 4 (01): : 49 - 54
  • [27] An in vivo comparison of five different electronic apex locators
    Al-Shaher, Abdulaziz A.
    Madi, Samar
    [J]. ENDO-ENDODONTIC PRACTICE TODAY, 2011, 5 (01): : 17 - 25
  • [28] Accuracy of four electronic apex locators:: an in vitro evaluation
    De Moor, RJG
    Hommez, GMG
    Martens, LC
    De Boever, JG
    [J]. ENDODONTICS & DENTAL TRAUMATOLOGY, 1999, 15 (02): : 77 - 82
  • [29] Influence of embedding media on the assessment of electronic apex locators
    Baldi, Jarcio V.
    Victorino, Fausto R.
    Bernardes, Ricardo A.
    de Moraes, Ivaldo G.
    Bramante, Colvis M.
    Garcia, Roberto B.
    Bernardineli, Norberti
    [J]. JOURNAL OF ENDODONTICS, 2007, 33 (04) : 476 - 479
  • [30] In vivo comparison of the accuracy of two electronic apex locators
    Silveira, Luiz F. M.
    Petry, Fernanda V.
    Martos, Josue
    Neto, Joao B. C.
    [J]. AUSTRALIAN ENDODONTIC JOURNAL, 2011, 37 (02) : 70 - 72