Interference of Electronic Apex Locators with Implantable Cardioverter Defibrillators

被引:15
|
作者
Idzahi, Karim [1 ,4 ]
de Cock, Carel C. [5 ,6 ]
Shemesh, Hagay [1 ]
Brand, Henk S. [2 ,3 ,4 ]
机构
[1] Univ Amsterdam, Acad Ctr Dent Amsterdam, Dept Endodontol, NL-1081 BT Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Ctr Dent Amsterdam, Dept Oral Biochem, NL-1081 BT Amsterdam, Netherlands
[3] Univ Amsterdam, Acad Ctr Dent Amsterdam, Dept Oral Maxillofacial Surg, NL-1081 BT Amsterdam, Netherlands
[4] Vrije Univ Amsterdam, NL-1081 LA Amsterdam, Netherlands
[5] Vrije Univ Amsterdam, Dept Cardiol, Med Ctr, NL-1081 LA Amsterdam, Netherlands
[6] Vrije Univ Amsterdam, Inst Cardiovasc Res VU, Med Ctr, NL-1081 LA Amsterdam, Netherlands
关键词
Electromagnetic interference; electronic apex locator; implantable cardioverter defibrillator; CARDIAC-PACEMAKER; DENTAL DEVICES; PULP TESTERS; PART II; ENVIRONMENT; PATIENT;
D O I
10.1016/j.joen.2013.07.027
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The purpose of this in vitro study was to evaluate the potential electromagnetic interference of electronic apex locators (EALs) on implantable cardioverter defibrillators (ICDs). Methods: Four different EALs were tested for their ability to interfere with the correct function of 3 different ICDs. Each ICD was placed in a plastic container with 1.5 L physiological saline, and the EAL unit was placed at a distance of 2.5 cm from the ICD. The file electrode and lip clip were placed directly against the ICD. The EAL was turned on for 30 seconds while continuously showing the "APEX" mark. As a negative control, the ICD was tested without EAL for 30 seconds. An electrosurgical unit served as a positive control. During each test, the ICD output was monitored continuously by real-time telemetry, and after completion of the experiment, intracardiac electrocardiograms were printed. The tests were repeated 3 times for each device. The electrocardiograms were examined for interference on ICD ventricular activity. Results: All EALs tested and the negative control failed to produce electromagnetic interference in each of the ICDs tested. The electrosurgical unit induced interference in the ICDs, which were detected as episodes of ventricular tachycardia and led to the initiation of electrical shocks in all ICDs. Conclusions: The 4 EALs tested did not interfere with the correct functioning of ICDs in vitro.
引用
收藏
页码:277 / 280
页数:4
相关论文
共 50 条
  • [2] Safety of electronic apex locators and pulp testers in patients with implanted cardiac pacemakers or cardioverter/defibrillators
    Wilson, Brian L.
    Broberg, Craig
    Baumgartner, J. Craig
    Harris, Chris
    Kron, Jack
    JOURNAL OF ENDODONTICS, 2006, 32 (09) : 847 - 852
  • [3] Incidence of electromagnetic interference in implantable cardioverter defibrillators
    Kolb, C
    Zrenner, B
    Schmitt, C
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (04): : 465 - 468
  • [4] Electromagnetic interference of dental equipment with implantable cardioverter defibrillators
    de Sant'Anna Dadalti, Manoela Teixeira
    Ledo Alves da Cunha, Antonio Jose
    Pimenta de Araujo, Marcos Cesar
    Belo de Moraes, Luis Gustavo
    Risso, Patricia de Andrade
    ACTA ODONTOLOGICA SCANDINAVICA, 2017, 75 (08) : 584 - 587
  • [5] Electromagnetic interference in implantable cardioverter defibrillators: present but rare
    Gesa von Olshausen
    Ina-Christine Rondak
    Carsten Lennerz
    Verena Semmler
    Christian Grebmer
    Tilko Reents
    Sonia Ammar-Busch
    Alessandra Buiatti
    Felix Bourier
    Isabel Deisenhofer
    Christof Kolb
    Clinical Research in Cardiology, 2016, 105 : 657 - 665
  • [6] Electromagnetic interference in implantable cardioverter defibrillators: present but rare
    von Olshausen, Gesa
    Rondak, Ina-Christine
    Lennerz, Carsten
    Semmler, Verena
    Grebmer, Christian
    Reents, Tilko
    Ammar-Busch, Sonia
    Buiatti, Alessandra
    Bourier, Felix
    Deisenhofer, Isabel
    Kolb, Christof
    CLINICAL RESEARCH IN CARDIOLOGY, 2016, 105 (08) : 657 - 665
  • [7] Implantable cardioverter defibrillators and cellular telephones: Is there any interference?
    Occhetta, E
    Plebani, L
    Bortnik, M
    Sacchetti, G
    Trevi, G
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (07): : 983 - 989
  • [8] Electronic apex locators
    Gordon, MPJ
    Chandler, NP
    INTERNATIONAL ENDODONTIC JOURNAL, 2004, 37 (07) : 425 - 437
  • [9] Implantable cardioverter defibrillators
    Shah, CP
    Thakur, RK
    Xie, BY
    Hoon, VK
    EMERGENCY MEDICINE CLINICS OF NORTH AMERICA, 1998, 16 (02) : 463 - +
  • [10] Implantable cardioverter defibrillators
    Cardiac Pacemakers, Inc, St. Paul, United States
    Proc IEEE, 3 (468-479):