Clinical Efficacy of Electronic Apex Locators: Systematic Review

被引:60
|
作者
Martins, Jorge N. R. [1 ,2 ,3 ]
Marques, Duarte [1 ,4 ,5 ]
Mata, Antonio [1 ,4 ,6 ]
Carames, Joao [1 ,5 ]
机构
[1] Univ Lisbon, Sch Dent Med, P-1699 Lisbon, Portugal
[2] NYU, Coll Dent, Inter PG Endodont, New York, NY USA
[3] Implantol Inst, Dept Endodont, Lisbon, Portugal
[4] Univ Lisbon, Evidence Based Dent Ctr, Oral Biol & Biochem Grp, Biomed & Oral Sci Res Unit,FCT Unit 4062, P-1699 Lisbon, Portugal
[5] Implantol Inst, Lisbon, Portugal
[6] NYU, Coll Dent, New York, NY USA
关键词
Electric impedance; electronics; odontometry; radiography; WORKING LENGTH DETERMINATION; ROOT-CANAL LENGTH; IN-VIVO EVALUATION; ENDODONTIC TREATMENT; POSTERIOR TEETH; TOOTH LENGTH; PART; ACCURACY; ZX; RADIOGRAPHS;
D O I
10.1016/j.joen.2014.03.011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: Apical constriction has been proposed as the most appropriate apical limit for the endodontic working length. Despite being the most used, some limitations are attributed to the radiographic method of working length determination. It lacks precision because it is based on the average position of the apical constriction. The electronic apex locators have been presented as an alternative to the odontometry performed by radiography. These devices detect the transition of the pulp to the periodontal tissue, which is anatomically very close to the apical constriction and may perform with improved accuracy. Methods: A systematic review was performed to compare the radiographic and electronic methods. Clinical studies that compared both methods were searched for on 7 electronic databases, a manual search was,performed on the bibliography of articles collected on the electronic databases, and the authors were contacted to ask for references of more research not detected on the electronic and manual search. Results: Twenty-one articles were selected. The majority were comparative or evaluation studies, and very few clinical studies comparing both methods are available. Several methodological limitations are present on the collected articles and debated in this review. Conclusions: Although the available scientific evidence base is short and at considerable risk of bias, it is still possible to conclude that the apical locator reduces the patient radiation exposure and also that the electronic method may perform better on the working length determination. At least one radiographic control should be performed to detect possible errors of the electronic devices.
引用
收藏
页码:759 / 777
页数:19
相关论文
共 50 条
  • [41] An in-vivo investigation of the performance of five electronic apex locators.
    Hooper, SM
    Meredith, N
    [J]. JOURNAL OF DENTAL RESEARCH, 1999, 78 (05) : 1061 - 1061
  • [42] Evaluation of Interference of Cellular Phones on Electronic Apex Locators: An In Vitro Study
    Sidhu, Preena
    Shankargouda, Swapnil
    Dicksit, Daniel DevaPrakash
    Mandey, Haydar Majeed
    Muzaffan, Danish
    Arora, Shelly
    [J]. JOURNAL OF ENDODONTICS, 2016, 42 (04) : 622 - 625
  • [43] In vitro evaluation of the accuracy of Root ZX series electronic apex locators
    Duh, Bor-Ren
    [J]. JOURNAL OF DENTAL SCIENCES, 2009, 4 (02) : 75 - 80
  • [44] The influence of two forms of chlorhexidine on the accuracy of contemporary electronic apex locators
    Ewa Marek
    Ryta Łagocka
    Katarzyna Kot
    Krzysztof Woźniak
    Mariusz Lipski
    [J]. BMC Oral Health, 20
  • [45] The influence of two forms of chlorhexidine on the accuracy of contemporary electronic apex locators
    Marek, Ewa
    Lagocka, Ryta
    Kot, Katarzyna
    Wozniak, Krzysztof
    Lipski, Mariusz
    [J]. BMC ORAL HEALTH, 2019, 20 (01)
  • [46] Effect of using electronic apex locators on selected endodontic treatment parameters
    Fouad, AF
    Reid, LC
    [J]. JOURNAL OF ENDODONTICS, 2000, 26 (06) : 364 - 367
  • [47] Precision of multi-frequency electronic apex locatorsQuestion: How precise are electronic apex locators in identifying the apical constriction?
    Roy George
    [J]. Evidence-Based Dentistry, 2016, 17 (3) : 86 - 87
  • [48] Accuracy of electronic apex locators in comparison to actual length - an in vivo study
    Haffner, C
    Folwaczny, M
    Galler, K
    Hickel, R
    [J]. JOURNAL OF DENTISTRY, 2005, 33 (08) : 619 - 625
  • [49] Comparison of working length determination with radiographs and four electronic apex locators
    Vieyra, J. P.
    Acosta, J.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2011, 44 (06) : 510 - 518
  • [50] Influence of Preflaring on the Accuracy of Length Determination With Four Electronic Apex Locators
    de Camargo, Ericson Janolio
    Zapata, Ronald Ordinola
    Medeiros, Paulo Leal
    Bramante, Clovis Monteiro
    Bernardineli, Norberti
    Garcia, Roberto Brandao
    de Moraes, Ivaldo Gomes
    Hungaro Duarte, Marco Antonio
    [J]. JOURNAL OF ENDODONTICS, 2009, 35 (09) : 1300 - 1302