Clinical Efficacy of Electronic Apex Locators: Systematic Review

被引:60
|
作者
Martins, Jorge N. R. [1 ,2 ,3 ]
Marques, Duarte [1 ,4 ,5 ]
Mata, Antonio [1 ,4 ,6 ]
Carames, Joao [1 ,5 ]
机构
[1] Univ Lisbon, Sch Dent Med, P-1699 Lisbon, Portugal
[2] NYU, Coll Dent, Inter PG Endodont, New York, NY USA
[3] Implantol Inst, Dept Endodont, Lisbon, Portugal
[4] Univ Lisbon, Evidence Based Dent Ctr, Oral Biol & Biochem Grp, Biomed & Oral Sci Res Unit,FCT Unit 4062, P-1699 Lisbon, Portugal
[5] Implantol Inst, Lisbon, Portugal
[6] NYU, Coll Dent, New York, NY USA
关键词
Electric impedance; electronics; odontometry; radiography; WORKING LENGTH DETERMINATION; ROOT-CANAL LENGTH; IN-VIVO EVALUATION; ENDODONTIC TREATMENT; POSTERIOR TEETH; TOOTH LENGTH; PART; ACCURACY; ZX; RADIOGRAPHS;
D O I
10.1016/j.joen.2014.03.011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: Apical constriction has been proposed as the most appropriate apical limit for the endodontic working length. Despite being the most used, some limitations are attributed to the radiographic method of working length determination. It lacks precision because it is based on the average position of the apical constriction. The electronic apex locators have been presented as an alternative to the odontometry performed by radiography. These devices detect the transition of the pulp to the periodontal tissue, which is anatomically very close to the apical constriction and may perform with improved accuracy. Methods: A systematic review was performed to compare the radiographic and electronic methods. Clinical studies that compared both methods were searched for on 7 electronic databases, a manual search was,performed on the bibliography of articles collected on the electronic databases, and the authors were contacted to ask for references of more research not detected on the electronic and manual search. Results: Twenty-one articles were selected. The majority were comparative or evaluation studies, and very few clinical studies comparing both methods are available. Several methodological limitations are present on the collected articles and debated in this review. Conclusions: Although the available scientific evidence base is short and at considerable risk of bias, it is still possible to conclude that the apical locator reduces the patient radiation exposure and also that the electronic method may perform better on the working length determination. At least one radiographic control should be performed to detect possible errors of the electronic devices.
引用
收藏
页码:759 / 777
页数:19
相关论文
共 50 条
  • [1] Electronic Apex Locators and their Implications in Contemporary Clinical Practice: A Review
    Shirazi, Zainab
    Al-Jadaa, Anas
    Saleh, Abdul Rahman
    [J]. OPEN DENTISTRY JOURNAL, 2023, 17
  • [2] Clinical reproducibility of three electronic apex locators
    Miletic, V.
    Beljic-Ivanovic, K.
    Ivanovic, V.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2011, 44 (08) : 769 - 776
  • [3] Electronic apex locators
    Gordon, MPJ
    Chandler, NP
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2004, 37 (07) : 425 - 437
  • [4] Influence and safety of electronic apex locators in patients with cardiovascular implantable electronic devices: a systematic review
    AlRahabi, Mothanna K.
    Ghabbani, Hani M.
    [J]. LIBYAN JOURNAL OF MEDICINE, 2019, 14 (01)
  • [5] Efficacy of electronic apex locators in comparison with intraoral radiographs in working length determination- a systematic review and meta-analysis
    Kaur, Gurveen
    Thomas, Anchu Rachel
    Samson, Renu Sarah
    Varghese, Eby
    Ponraj, Ratna Rachel
    Nagraj, Sumanth Kumbargere
    Shrivastava, Deepti
    Algarni, Hmoud Ali
    Siddiqui, Amna Yusuf
    Alothmani, Osama S.
    Srivastava, Kumar Chandan
    [J]. BMC ORAL HEALTH, 2024, 24 (01)
  • [6] Use of electronic apex locators may improve determination of working lengthQuestion: Are electronic apex locators (EALs) accurate?
    Isabel Mello
    [J]. Evidence-Based Dentistry, 2014, 15 (4) : 120 - 120
  • [7] The Precision of Electronic Apex Locators in Working Length Determination: A Systematic Review and Meta-analysis of the Literature
    Tsesis, Igor
    Blazer, Tamar
    Ben-Izhack, Gil
    Taschieri, Silvio
    Del Fabbro, Massimo
    Corbella, Stefano
    Rosen, Eyal
    [J]. JOURNAL OF ENDODONTICS, 2015, 41 (11) : 1818 - 1823
  • [8] Are electronic apex locators accurate in determining working length in primary teeth pulpectomies? A systematic review and meta-analysis of clinical studies
    Vitali, Filipe Colombo
    Santos, Pablo Silveira
    Cardoso, Mariane
    Massignan, Carla
    Garcia, Lucas da Fonseca Roberti
    Bortoluzzi, Eduardo Antunes
    Teixeira, Cleonice da Silveira
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2022, 55 (10) : 989 - 1009
  • [9] In Vitro Comparison of Three Electronic Apex Locators
    Guise, George M.
    Goodell, Gary G.
    Imamura, Glen M.
    [J]. JOURNAL OF ENDODONTICS, 2010, 36 (02) : 279 - 281
  • [10] An overview of electronic apex locators: part 1
    Ali, R.
    Okechukwu, N. C.
    Brunton, P.
    Nattress, B.
    [J]. BRITISH DENTAL JOURNAL, 2013, 214 (04) : 155 - 158