Are electronic apex locators accurate in determining working length in primary teeth pulpectomies? A systematic review and meta-analysis of clinical studies

被引:8
|
作者
Vitali, Filipe Colombo [1 ]
Santos, Pablo Silveira [1 ]
Cardoso, Mariane [2 ]
Massignan, Carla [3 ]
Garcia, Lucas da Fonseca Roberti [2 ]
Bortoluzzi, Eduardo Antunes [2 ]
Teixeira, Cleonice da Silveira [2 ]
机构
[1] Univ Fed Santa Catarina, Postgrad Program Dent, Florianopolis, SC, Brazil
[2] Univ Fed Santa Catarina, Dept Dent, Florianopolis, SC, Brazil
[3] Univ Brasilia, Dept Dent, Brasilia, DF, Brazil
关键词
electronic apex locator; meta-analysis; systematic review; tooth; deciduous; working length; VITAL PULP THERAPY; ROOT ZX; CONVENTIONAL RADIOGRAPHY; CANAL INSTRUMENTATION; PRIMARY MOLARS; QUALITY; RESORPTION; CERTAINTY; BIAS;
D O I
10.1111/iej.13798
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background The lack of a well-defined apical constriction in primary teeth raises concerns regarding the accuracy of electronic apex locators (EALs) for measuring working length. Objectives To evaluate the accuracy of EALs in determining working length in primary teeth pulpectomies. Methods Two reviewers searched ten databases up to September 2021. Clinical studies evaluating the accuracy of the electronic measurement of working length in primary teeth pulpectomies were included. Studies without a comparison group, with samples smaller than ten root canals, and that did not use a multiple frequency EAL were excluded. A meta-analysis was conducted to assess the paired differences in mean lengths between measurements obtained by electronic and comparative methods. In addition, a meta-analysis of proportion was applied according to the level of difference between the measures. The risk of bias and applicability of the studies were assessed using the QUADAS-2 tool. The certainty of evidence was assessed with the Grading of Recommendations, Assessment, Development and Evaluation (GRADE) approach. Results Twenty-nine studies were included in the qualitative analysis and twenty-three in the quantitative analysis. The methods of comparison for the electronic measurement were the radiographic method, radiovisiographic, scanning electron microscopy, and direct visualization. The meta-analysis showed that the electronic measurement tends to be shorter than radiographic measurement, while the other methods showed no difference. The proportion analysis showed a higher pooled proportion of difference values between electronic and comparative measurements within -0.5 to +0.5 mm (69.31%). The certainty of the evidence suggested very low confidence in estimating the outcome. Discussion The results of this review denote a good performance of the EALs in determining working length in primary teeth pulpectomies. However, these results are based on clinical studies with low methodological quality and high heterogeneity, which require careful interpretation for clinical practice. Conclusions Although the results suggest acceptable accuracy of EALs in determining working length in primary teeth pulpectomies, the low quality of the included studies and the very low certainty of the evidence require clinicians to interpret these results with caution. More robust evidence is required to support that these devices are accurate for primary teeth. Registration CRD42021277414 (PROSPERO).
引用
收藏
页码:989 / 1009
页数:21
相关论文
共 50 条
  • [1] Accuracy of different generations of apex locators in determining working length; a systematic review and meta-analysis
    Nasiri, Kaveh
    Wrbas, Karl-Thomas
    SAUDI DENTAL JOURNAL, 2022, 34 (01) : 11 - 20
  • [2] The Precision of Electronic Apex Locators in Working Length Determination: A Systematic Review and Meta-analysis of the Literature
    Tsesis, Igor
    Blazer, Tamar
    Ben-Izhack, Gil
    Taschieri, Silvio
    Del Fabbro, Massimo
    Corbella, Stefano
    Rosen, Eyal
    JOURNAL OF ENDODONTICS, 2015, 41 (11) : 1818 - 1823
  • [3] Accuracy of electronic apex locators in primary teeth: a meta-analysis
    Ahmad, I. A.
    Pani, S. C.
    INTERNATIONAL ENDODONTIC JOURNAL, 2015, 48 (03) : 298 - 307
  • [4] Integrated electronic apex locators for determining working length: a systematic review of in-vitro studies
    La Rosa, Giusy Rita Maria
    Angjelova, Angela
    Jovanova, Elena
    Apostolska, Sonja
    Santos, Joao Miguel
    Pedulla, Eugenio
    ODONTOLOGY, 2024,
  • [5] Conventional methods and electronic apical locator in determining working length in different primary teeth: systematic review and meta-analysis of clinical studies
    Mourao, Priscila Seixas
    Fernandes, Izabella Barbosa
    Moreira, Luana Viviam
    Machado, Gabrielly Fernandes
    Falci, Saulo Gabriel Moreira
    de Souza, Glaciele Maria
    Ramos-Jorge, Maria Leticia
    EVIDENCE-BASED DENTISTRY, 2025,
  • [6] The accuracy of electronic apex locators for determining working length: An in vitro study with artificial teeth
    Bernardo, Raquel C. F. D.
    Alves, Louise S.
    Bruno, Adilia M., V
    Coutinho, Thais M. C.
    Gusman, Heloisa
    AUSTRALIAN ENDODONTIC JOURNAL, 2021, 47 (02) : 217 - 221
  • [7] Efficacy of electronic apex locators in comparison with intraoral radiographs in working length determination- a systematic review and meta-analysis
    Kaur, Gurveen
    Thomas, Anchu Rachel
    Samson, Renu Sarah
    Varghese, Eby
    Ponraj, Ratna Rachel
    Nagraj, Sumanth Kumbargere
    Shrivastava, Deepti
    Algarni, Hmoud Ali
    Siddiqui, Amna Yusuf
    Alothmani, Osama S.
    Srivastava, Kumar Chandan
    BMC ORAL HEALTH, 2024, 24 (01)
  • [8] Modern electronic apex locators are reliable for determining root canal working length: How accurate are electronic apex locators in the determination of root canal length?
    Balto K.A.
    Evidence-Based Dentistry, 2006, 7 (2) : 31 - 32
  • [9] Working length determination in primary teeth pulpectomy: A systematic review and meta-analysis
    Paradiso, Daniele
    Tullio, Antonio
    Bensi, Caterina
    AUSTRALIAN ENDODONTIC JOURNAL, 2023, 49 (02) : 444 - 454
  • [10] Clinical Efficacy of Electronic Apex Locators: Systematic Review
    Martins, Jorge N. R.
    Marques, Duarte
    Mata, Antonio
    Carames, Joao
    JOURNAL OF ENDODONTICS, 2014, 40 (06) : 759 - 777