摘要
Background Conflicting studies exist about the effectiveness of cardiopulmonary resuscitation (CPR) on a dental chair. In some situations, dental surgeons are obliged to perform CPR with the patient on the chair. Feedback devices are supposed to guide the compression depth in order to improve the quality of CPR, but some devices are based on an accelerometer that can theoretically report erroneous results because of the lack of rigidity of a dental chair. Objective The aim of this study was to evaluate the accuracy of these devices to guide chest compressions on a dental chair. Methods A prospective, randomised, crossover, equivalence/non-inferiority study was conducted to compare the values of compression depths provided by the feedback device (Real CPR Help (R), delivered by Zoll (c) Medical Corporation, Chelmsford, MA, USA) with the real measurements provided by the manikin (Resusci Anne (R) Advanced SkillTrainer, Laerdal Medical AS (c), Norway). Chest-compression-only CPR was performed by 15 Basic Life Support instructors who carried out two rounds of continuous CPR for 2 min each. Data were analysed with a correlation test, a Bland-Altman method and a Wilcoxon test. Statistical significance was defined as p<0.05. Results A significant difference was found between the mean depths of compression measured by the feedback device and the manikin on a dental chair and on the floor (p<0.0001). The feedback device overestimated the depth of chest compressions, and Bland-Altman analysis demonstrated poor agreement. Conclusion This study indicates that feedback devices with accelerometer technology are not sufficiently reliable to ensure adequate chest compression on dental chairs.
引用
收藏
页码:890 / 893
页数:4
相关论文
共 50 条
  • [21] Feedback Devices for Cardiopulmonary Resuscitation: A Narrative Review
    Wang, Yuxin
    Ma, Shuai
    Chen, Zetao
    Fan, Bin
    Hou, Shike
    APPLIED SCIENCES-BASEL, 2023, 13 (18):
  • [22] Accuracy of the cardiopulmonary resuscitation registry in an emergency department
    Park, Hyun Soo
    Jung, Sung Koo
    Kim, Hee Chan
    EMERGENCY MEDICINE JOURNAL, 2012, 29 (04) : 287 - 289
  • [23] Force measuring device applied in cardiopulmonary resuscitation
    Santic, A
    Kovacic, D
    Gilly, H
    MEDICON 2001: PROCEEDINGS OF THE INTERNATIONAL FEDERATION FOR MEDICAL & BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2001, : 273 - 276
  • [24] Use of the impedance threshold device in cardiopulmonary resuscitation
    Demestiha, Theano D.
    Pantazopoulos, Ioannis N.
    Xanthos, Theodoros T.
    WORLD JOURNAL OF CARDIOLOGY, 2010, 2 (02): : 19 - 26
  • [25] The impact of post-resuscitation feedback for paramedics on the quality of cardiopulmonary resuscitation
    Bleijenberg, Eduard
    Koster, Rudolph W.
    de Vries, Hendrik
    Beesems, Stefanie G.
    RESUSCITATION, 2017, 110 : 1 - 5
  • [26] Effective Method Using a Stool in Cardiopulmonary Resuscitation (CPR) on Dialysis Chair
    Ifuku, Takeshi
    Hitosugi, Takashi
    Kawakubo, Yoshfumi
    Tanaka, Tomoyuki
    Doi, Kazuto
    Yokoyama, Takeshi
    EMERGENCY MEDICINE INTERNATIONAL, 2020, 2020
  • [27] A comparison of video review and feedback device measurement of chest compressions quality during pediatric cardiopulmonary resuscitation
    Hsieh, Ting-Chang
    Wolfe, Heather
    Sutton, Robert
    Myers, Sage
    Nadkarni, Vinay
    Donoghue, Aaron
    RESUSCITATION, 2015, 93 : 35 - 39
  • [28] Quantification of Passive Ventilation Produced by Manual Chest Compressions Using a New Cardiopulmonary Resuscitation Feedback Device
    Ben Taleb, Lhoucine
    Essoukaki, Elmaati
    Mouhsen, Azeddine
    Lyazidi, Aissam
    Assir, Abdelhadi
    Harmouchi, Mohammed
    Rattal, Mourad
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2020, 14 (02):
  • [29] Effect of introducing a feedback device during adult and infant cardiopulmonary resuscitation training: A 'before and after' study
    Kim, Kwan Ho
    Kim, Chan Woong
    Oh, Je Hyeok
    HONG KONG JOURNAL OF EMERGENCY MEDICINE, 2020, 27 (02) : 114 - 117
  • [30] Assessing practical skills in cardiopulmonary resuscitation Discrepancy between standard visual evaluation and a mechanical feedback device
    Sanchez Gonzalez, Baltasar
    Martinez, Laura
    Cerda, Manel
    Piacentini, Enrique
    Trenado, Josep
    Quintana, Salvador
    MEDICINE, 2017, 96 (13)