Quantification of Passive Ventilation Produced by Manual Chest Compressions Using a New Cardiopulmonary Resuscitation Feedback Device

被引:0
|
作者
Ben Taleb, Lhoucine [1 ]
Essoukaki, Elmaati [1 ]
Mouhsen, Azeddine [1 ]
Lyazidi, Aissam [1 ,2 ]
Assir, Abdelhadi [1 ]
Harmouchi, Mohammed [1 ]
Rattal, Mourad [1 ,2 ]
机构
[1] Univ Hassan 1, Lab RMI, Settat 26000, Morocco
[2] Univ Hassan 1, Lab STS, Settat 26000, Morocco
关键词
CPR; chest compressions; passive ventilation; feedback device; AIRWAY PRESSURE; QUALITY; CPR; MANNEQUIN; MASSAGE; IMPACT;
D O I
10.1115/1.4046512
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Several studies have shown that chest compressions (CC) alone may produce in addition to blood circulation, a short-term passive ventilation. However, it is not clear whether high CC quality may produce in even greater amount of ventilation volumes. The aim of this study was to evaluate whether CC, using a new feedback device, can produce a substantial and sustainable passive volumes compared to standard CC. Thirty inexperienced volunteers performed CC for 2 min on a developed thoracic lung model and using a new feedback device. Participants were randomized into two groups that performed either CC with feedback first, followed by a trial without feedback, or vice versa. Efficient compression rate (correct CC rate and depth simultaneously) was significantly higher in feedback session (43.6% versus 25.5%; P = 0.006). As well, CC rate and depth efficiency were improved with feedback. Moreover, average tidal volumes and minute volumes that occurred during CC alone were significantly improved in feedback session (79.8 +/- 5 ml versus 72.9 +/- 7 ml) and (8.8 l/min versus 7.9 l/min), respectively (P < 0.001). Yet, no significant difference was found between the first and the 90th second interval (9.04 l/min versus 8.68 l/min, P = 0.163) in the feedback session. Conversely, a significant difference was evident after the first 15th seconds interval without feedback (8.77 l/min initially versus 8.38 l/min; P = 0.041). This study revealed that the new CPR feedback device improved CC quality in inexperienced volunteers. As well, the passive ventilation volumes were significantly increased and sustained when the device was used.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Do manual chest compressions provide substantial ventilation during prehospital cardiopulmonary resuscitation?
    Vanwulpen, Maxim
    Wolfskeil, Martha
    Duchatelet, Christophe
    Hachimi-Idrissi, Said
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2021, 39 : 129 - 131
  • [2] Quantification of ventilation volumes produced by compressions during emergency department cardiopulmonary resuscitation
    McDannold, Robyn
    Bobrow, Bentley J.
    Chikani, Vatsal
    Silver, Annemarie
    Spaite, Daniel W.
    Vadeboncoeur, Tyler
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2018, 36 (09): : 1640 - 1644
  • [3] A New Method for Feedback on the Quality of Chest Compressions during Cardiopulmonary Resuscitation
    Gonzalez-Otero, Digna M.
    Ruiz, Jesus
    Ruiz de Gauna, Sofia
    Irusta, Unai
    Ayala, Unai
    Alonso, Erik
    [J]. BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [4] The Role of Chest Compressions on Ventilation during Advanced Cardiopulmonary Resuscitation
    Azcarate, Izaskun
    Uriguen, Jose Antonio
    Leturiondo, Mikel
    Sandoval, Camilo Leonardo
    Redondo, Koldo
    Gutierrez, Jose Julio
    Russell, James Knox
    Wallmueller, Pia
    Sterz, Fritz
    Daya, Mohamud Ramzan
    de Gauna, Sofia Ruiz
    [J]. JOURNAL OF CLINICAL MEDICINE, 2023, 12 (21)
  • [5] Ventilation generated by manual chest compressions declines during cardiopulmonary resuscitation: evidence of small airways closure?
    Vanwulpen, M.
    Duchatelet, C.
    Wolfskeil, M.
    Van Daele, C.
    Hachimi-Idrissi, S.
    [J]. ACTA CLINICA BELGICA, 2020, 75 : 7 - 8
  • [6] A Method to Evaluate the Quality of Chest Compressions During Manual Cardiopulmonary Resuscitation
    Sun, Mingze
    Pan, Chang
    Pang, Jiaojiao
    Wang, Jiali
    Li, Ke
    Xu, Feng
    Chen, Yuguo
    [J]. 2022 INTERNATIONAL CONFERENCE ON ADVANCED ROBOTICS AND MECHATRONICS (ICARM 2022), 2022, : 325 - 330
  • [7] Evaluation of manual chest compressions according to the updated cardiopulmonary resuscitation guidelines and the impact of feedback devices in an educational resuscitation course
    Urushibata, Nao
    Murata, Kiyoshi
    Endo, Hideki
    Yoshiyuki, Ayako
    Otomo, Yasuhiro
    [J]. BMC EMERGENCY MEDICINE, 2020, 20 (01)
  • [8] Evaluation of manual chest compressions according to the updated cardiopulmonary resuscitation guidelines and the impact of feedback devices in an educational resuscitation course
    Nao Urushibata
    Kiyoshi Murata
    Hideki Endo
    Ayako Yoshiyuki
    Yasuhiro Otomo
    [J]. BMC Emergency Medicine, 20
  • [9] Comparison of the effectiveness of cardiopulmonary resuscitation with standard manual chest compressions and the use of TrueCPR and PocketCPR feedback devices
    Kurowski, Andrzej
    Szarpak, Lukasz
    Bogdanski, Lukasz
    Zasko, Piotr
    Czyzewski, Lukasz
    [J]. KARDIOLOGIA POLSKA, 2015, 73 (10) : 924 - 930
  • [10] Feedback on the Rate and Depth of Chest Compressions during Cardiopulmonary Resuscitation Using Only Accelerometers
    Ruiz de Gauna, Sofia
    Gonzalez-Otero, Digna M.
    Ruiz, Jesus
    Russell, James K.
    [J]. PLOS ONE, 2016, 11 (03):