Assessing practical skills in cardiopulmonary resuscitation Discrepancy between standard visual evaluation and a mechanical feedback device

被引:13
|
作者
Sanchez Gonzalez, Baltasar [1 ,2 ]
Martinez, Laura [1 ,3 ]
Cerda, Manel [2 ]
Piacentini, Enrique [1 ,3 ]
Trenado, Josep [1 ,3 ]
Quintana, Salvador [1 ,2 ,3 ]
机构
[1] Univ Barcelona, Hosp Univ Mutua Terrassa, Dept Intens Care, Terrassa, Spain
[2] Consell Catala Ressuscitacio, Barcelona, Spain
[3] Univ Barcelona, Hosp Univ Mutua Terrassa, Dept Intens Care, Terrassa, Spain
关键词
cardiopulmonary resuscitation quality; cardiopulmonary resuscitation simulation; cardiopulmonary resuscitation training; chest compressions quality; feedback from mechanical devices in CPR; inter-rater agreement; CHEST COMPRESSIONS; AUDIOVISUAL FEEDBACK; QUALITY; AGREEMENT; PERFORMANCE; MANNEQUIN; SURVIVAL; DEPTH;
D O I
10.1097/MD.0000000000006515
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This paper aims to analyze agreement in the assessment of external chest compressions (ECC) by 3 human raters and dedicated feedback software. While 54 volunteer health workers (medical transport technicians), trained and experienced in cardiopulmonary resuscitation (CPR), performed a complete sequence of basic CPR maneuvers on a manikin incorporating feedback software (Laerdal PC v 4.2.1 Skill Reporting Software) (L), 3 expert CPR instructors (A, B, and C) visually assessed ECC, evaluating hand placement, compression depth, chest decompression, and rate. We analyzed the concordance among the raters (A, B, and C) and between the raters and L with Cohen's kappa coefficient (K), intraclass correlation coefficients (ICC), Bland-Altman plots, and survival-agreement plots. The agreement (expressed as Cohen's K and ICC) was >= 0.54 in only 3 instances and was <= 0.45 in more than half. Bland-Altman plots showed significant dispersion of the data. The survival-agreement plot showed a high degree of discordance between pairs of raters (A-L, B-L, and C-L) when the level of tolerance was set low. In visual assessment of ECC, there is a significant lack of agreement among accredited raters and significant dispersion and inconsistency in data, bringing into question the reliability and validity of this method of measurement.
引用
收藏
页数:5
相关论文
共 13 条
  • [1] A comparison of standard manual cardiopulmonary resuscitation versus the autopulse mechanical cardiopulmonary resuscitation device
    Lairet, JR
    Lee, M
    ANNALS OF EMERGENCY MEDICINE, 2005, 46 (03) : S114 - S114
  • [2] Advantage and Limitation of Using a Visual Feedback Device during Cardiopulmonary Resuscitation Training
    Kim, Chan Woong
    Oh, Je Hyeok
    PREHOSPITAL AND DISASTER MEDICINE, 2020, 35 (01) : 104 - 108
  • [3] Effect Of A Visual Feedback Device On The Acquisition Of Cardiopulmonary Resuscitation Skills In Training Certified By The American Heart Association: Randomized Clinical Trial
    Castro, Carina
    Vaz, Jacqueline
    de Mattos, Mariana Oliveira Tripoli
    Barbisan, Juarez
    CIRCULATION, 2024, 150
  • [4] Clinical evaluation of an inspiratory impedance threshold device during standard cardiopulmonary resuscitation
    Aufderheide, TP
    Pirrallo, RG
    Provo, TA
    Lurie, KG
    CIRCULATION, 2004, 110 (17) : 413 - 413
  • [5] Quality of cardiopulmonary resuscitation: Degree of agreement between instructor and a feedback device during a simulation exercise
    Arrogante, Oscar
    Maria Gonzalez-Romero, Gracia
    Manuel Caperos, Jose
    Samith, Sabrina
    Carrion-Garcia, Laura
    Rios-Diaz, Jose
    INTERNATIONAL EMERGENCY NURSING, 2020, 53
  • [6] Mechanical Active Compression-Decompression Cardiopulmonary Resuscitation provide higher Airway Carbon Dioxide Values Compared to a Standard Mechanical Device During Out-of-Hospital Cardiopulmonary Resuscitation
    Svensoy, Johannes N.
    Elola, Andoni
    Berve, Per Olav
    Alonso, Erik
    Hardig, Bjarne M.
    Raeder, Johan
    Skalhegg, Tore
    Aramendi, Elisabete
    Wik, Lars
    ANESTHESIA AND ANALGESIA, 2024, 139 (06):
  • [7] Deliberate practice in resuscitation training using a feedback device, and the effects of the physical characteristics of the rescuer on the acquisition and retention of cardiopulmonary resuscitation skills: Randomized clinical trial
    Arrogante, Oscar
    Rios-Diaz, Jose
    Carrion-Garcia, Laura
    Samith, Sabrina
    Gonzalez-Romero, Gracia Maria
    Manuel Caperos, Jose
    INTERNATIONAL EMERGENCY NURSING, 2021, 58
  • [8] Role of Real-Time Visual Feedback Device on Cardiopulmonary Resuscitation Training Among School Children: A Randomized Controlled Trial
    Sahu, A.
    Thakur, N.
    Mathew, R.
    Bhoi, S.
    Aggarwal, P.
    ANNALS OF EMERGENCY MEDICINE, 2023, 82 (04) : S160 - S161
  • [9] Clinical evaluation of an inspiratory impedance threshold device during standard cardiopulmonary resuscitation in patients with out-of-hospital cardiac arrest
    Aufderheide, TP
    Pirrallo, RG
    Provo, TA
    Lurie, KG
    CRITICAL CARE MEDICINE, 2005, 33 (04) : 734 - 740
  • [10] Increased cortical cerebral blood flow with LUCAS; a new device for mechanical chest compressions compared to standard external compressions during experimental cardiopulmonary resuscitation
    Rubertsson, S
    Karlsten, R