Quality of cardiopulmonary resuscitation: Degree of agreement between instructor and a feedback device during a simulation exercise

被引:3
|
作者
Arrogante, Oscar [1 ]
Maria Gonzalez-Romero, Gracia [1 ]
Manuel Caperos, Jose [1 ]
Samith, Sabrina [1 ]
Carrion-Garcia, Laura [1 ]
Rios-Diaz, Jose [1 ]
机构
[1] Univ Nebrija, Ctr Ciencias Salud San Rafael, Fdn San Juan Dios, Paseo Habana 70, Madrid 28036, Spain
关键词
Cardiopulmonary resuscitation; Education; Nursing; Quality; Simulation; Training; ASSOCIATION GUIDELINES UPDATE; HOSPITAL CARDIAC-ARREST; EUROPEAN RESUSCITATION; CHEST COMPRESSIONS; COUNCIL GUIDELINES; VISUAL FEEDBACK; TIME; CPR; COEFFICIENT; RELIABILITY;
D O I
10.1016/j.ienj.2020.100907
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Background: High-quality cardiopulmonary resuscitation (CPR) saves lives after a cardiorespiratory arrest. Currently used feedback devices (FD) provide accurate information on CPR quality during training. However, there is no consensus in previous studies that have compared FD to the feedback provided by an instructor and most show methodological limitations. This study aimed to analyse the degree of agreement between an FD and an instructor in the assessment of high-quality CPR. Method: 60 undergraduate nursing students participated in a descriptive observational study. Variables related to the quality of chest compressions (CC) and ventilation were recorded. Students were evaluated during 2 minute compression/ventilation cycles by an expert instructor and using the CPR training torso, Little AnneTM QCPR (Laerdal Medical) with its associated QCPR Instructor App software for iOS. Results: The degree of agreement between instructor and FD assessments was moderate-good: CC rate per minute (Intracass correlation coeficiente [ICC] = 0.791), complete chest recoil (ICC = 0.437); CC depth (k = 0.804); CC with correct depth (ICC = 0.557); correct ventilations (k = 0.510); ventilations per cycle (ICC = 0.635); CC per cycle (ICC = 0.215); overall quality of CPR (ICC = 0.602). However, the degree of agreement should be considered poor since the limits were broad. Conclusions: Although there were discrepancies between the FD and the instructor, it would be advisable to follow a combined approach in CPR training, whereby the quantitative feedback supplied by the FD is complemented by the qualitative assessment of an instructor.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Using a Feedback Device to Improve Quality of Cardiopulmonary Resuscitation
    Kupchik, Nicole
    Nehmer, Maria
    CRITICAL CARE NURSE, 2016, 36 (02) : E42 - E42
  • [2] Feedback during cardiopulmonary resuscitation
    Bohn, Andreas
    Gude, Philipp
    CURRENT OPINION IN ANESTHESIOLOGY, 2008, 21 (02) : 200 - 203
  • [3] A comparison of video review and feedback device measurement of chest compressions quality during pediatric cardiopulmonary resuscitation
    Hsieh, Ting-Chang
    Wolfe, Heather
    Sutton, Robert
    Myers, Sage
    Nadkarni, Vinay
    Donoghue, Aaron
    RESUSCITATION, 2015, 93 : 35 - 39
  • [4] Design of a new feedback device for Cardiopulmonary Resuscitation
    Lhoucine, Ben Taleb
    Elmaati, Essoukaki
    Aissam, Lyazidi
    Azeddine, Mouhsen
    Abdelhadi, Assir
    Mourad, Rattal
    Mohammed, Harmouchi
    2018 IEEE 4TH MIDDLE EAST CONFERENCE ON BIOMEDICAL ENGINEERING (MECBME), 2018, : 90 - 95
  • [5] Effect of Audiovisual Cardiopulmonary Resuscitation Feedback Device on Improving Chest Compression Quality
    Chia-Ying Lin
    Shao-Hsuan Hsia
    En-Pei Lee
    Oi-Wa Chan
    Jainn-Jim Lin
    Han-Ping Wu
    Scientific Reports, 10
  • [6] Effect of Audiovisual Cardiopulmonary Resuscitation Feedback Device on Improving Chest Compression Quality
    Lin, Chia-Ying
    Hsia, Shao-Hsuan
    Lee, En-Pei
    Chan, Oi-Wa
    Lin, Jainn-Jim
    Wu, Han-Ping
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [7] Hand injuries caused by feedback device usage during cardiopulmonary resuscitation training
    Hong, Jun Young
    Oh, Je Hyeok
    Kim, Chan Woong
    Lee, Dong Hoon
    RESUSCITATION, 2016, 107 : E3 - E4
  • [8] A New Method for Feedback on the Quality of Chest Compressions during Cardiopulmonary Resuscitation
    Gonzalez-Otero, Digna M.
    Ruiz, Jesus
    Ruiz de Gauna, Sofia
    Irusta, Unai
    Ayala, Unai
    Alonso, Erik
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [9] Advantage and Limitation of Using a Visual Feedback Device during Cardiopulmonary Resuscitation Training
    Kim, Chan Woong
    Oh, Je Hyeok
    PREHOSPITAL AND DISASTER MEDICINE, 2020, 35 (01) : 104 - 108
  • [10] Simulation of an Electro-Mechanical Resuscitation Device for Cardiopulmonary Resuscitation
    Garcia, Alejandro Mendoza
    Eichhorn, Stefan
    Polski, Marcin
    Knoll, Alois
    2014 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), VOL 41, 2014, 41 : 1049 - 1052