Research of a Water Hydraulic Piston Pump Applied for Water Mist Fire Suppression System

被引:0
|
作者
Zhang Zuti [1 ]
Qu Xuliang [1 ]
Luo Xiaohui [1 ]
Cao Shuping [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Mech Sci & Engn, Wuhan 430074, Hubei, Peoples R China
关键词
piston pump; water mist fire suppression; pressure pulsation;
D O I
暂无
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Fire is one of the fatal threats in manned spacecraft, water mist fire suppression technology has become one of the most important methods to preventing fires. As the main motive components, high pressure water hydraulic piston pump is very important for the development of water mist fire suppression technology. A novel crankshaft piston pump was studied through simulations and experiments in this paper. Furthermore, an attenuator was designed and utilized to reduce the pressure pulsation for the improvement of the performance of the piston pump. Analysis results show that the pump has many essential advantages, such as little lateral force, low PV value, good friction and wear conditions, as well as high volumetric efficiency. In addition, the performances of the pump were obtained through simulations using AMESim. Simulation results indicated that the piston pump has a good flow rate property. The flow rate is well in agreement with the theoretic design and it reaches to 235L/min. However, the flow pulsation unavoidably occurs, and it further causes pressure pulsation. Generally, the pressure pulsation frequency is the product of the shaft rotation frequency and the piston number. Fortunately, the utilization of attenuator could effectively reduce the pressure pulsation, so that the performance of the piston pump is well improved. The pressure pulsation ratio could be reduced to 1%. The new type crankshaft piston pump with low pressure pulsation is helpful to the development of water hydraulic technology and the water mist fire suppression system.
引用
收藏
页码:30 / 35
页数:6
相关论文
共 50 条
  • [41] Experimental study on the pulse water mist fire suppression system performance in a confined space
    P. Y. Lun
    Q. Zhang
    X. K. Li
    [J]. Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2020, 42
  • [42] CONCEPT DESIGN AND TESTING OF MULTI-NOZZLE WATER MIST FIRE SUPPRESSION SYSTEM
    Sumarsono, Danardono A.
    Nugroho, Yulianto S.
    Mariance
    Ariasa, I. Gede Wahyu W.
    [J]. MAKARA JOURNAL OF TECHNOLOGY, 2010, 14 (02): : 138 - 142
  • [43] Experiment on Water Mist Fire Suppression in Long and Narrow Spaces
    Liu Jianghong
    Zhu Wei
    Liao Guangxuan
    [J]. PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL. VIII, PTS A AND B, 2010, 8 : 798 - 806
  • [44] Experimental study on the pulse water mist fire suppression system performance in a confined space
    Lun, P. Y.
    Zhang, Q.
    Li, X. K.
    [J]. JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2020, 42 (05)
  • [45] On water mist fire suppression mechanisms in a gaseous diffusion flame
    Ndubizu, CC
    Ananth, R
    Tatem, PA
    Motevalli, V
    [J]. FIRE SAFETY JOURNAL, 1998, 31 (03) : 253 - 276
  • [46] A zone model in simulating water mist suppression on obstructed fire
    Li, Y. F.
    Chow, W. K.
    [J]. HEAT TRANSFER ENGINEERING, 2006, 27 (10) : 99 - 115
  • [47] Experimental research on the water mist fire suppression performance in an enclosed space by changing the characteristics of nozzles
    Liu Yinshui
    Jiang Zhuo
    Wang Dan
    Li Xiaohui
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2014, 52 : 174 - 181
  • [48] Comprehensive analysis of contact stress between piston and cylinder in water hydraulic piston pump
    Yu, Zuyao
    Li, Zhungyun
    Nie, Songlin
    Zhang, Tiehua
    [J]. Zhongguo Jixie Gongcheng/China Mechanical Engineering, 2002, 13 (03):
  • [49] Analyses of fire suppression experiments of sheltered fire sources in wind generator compartment using water mist system
    Chiu, Chen-Wei
    Shu, Yi-Liang
    Hsu, Hui-Kuan
    [J]. Journal of Applied Fire Science, 2011, 21 (04): : 343 - 362
  • [50] Extinguishment of cooking oil fires by water mist fire suppression systems
    Liu, ZG
    Kim, AK
    Carpenter, D
    Kanabus-Kaminska, JM
    [J]. FIRE TECHNOLOGY, 2004, 40 (04) : 309 - 333