Research of a Water Hydraulic Piston Pump Applied for Water Mist Fire Suppression System

被引:0
|
作者
Zhang Zuti [1 ]
Qu Xuliang [1 ]
Luo Xiaohui [1 ]
Cao Shuping [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Mech Sci & Engn, Wuhan 430074, Hubei, Peoples R China
关键词
piston pump; water mist fire suppression; pressure pulsation;
D O I
暂无
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Fire is one of the fatal threats in manned spacecraft, water mist fire suppression technology has become one of the most important methods to preventing fires. As the main motive components, high pressure water hydraulic piston pump is very important for the development of water mist fire suppression technology. A novel crankshaft piston pump was studied through simulations and experiments in this paper. Furthermore, an attenuator was designed and utilized to reduce the pressure pulsation for the improvement of the performance of the piston pump. Analysis results show that the pump has many essential advantages, such as little lateral force, low PV value, good friction and wear conditions, as well as high volumetric efficiency. In addition, the performances of the pump were obtained through simulations using AMESim. Simulation results indicated that the piston pump has a good flow rate property. The flow rate is well in agreement with the theoretic design and it reaches to 235L/min. However, the flow pulsation unavoidably occurs, and it further causes pressure pulsation. Generally, the pressure pulsation frequency is the product of the shaft rotation frequency and the piston number. Fortunately, the utilization of attenuator could effectively reduce the pressure pulsation, so that the performance of the piston pump is well improved. The pressure pulsation ratio could be reduced to 1%. The new type crankshaft piston pump with low pressure pulsation is helpful to the development of water hydraulic technology and the water mist fire suppression system.
引用
收藏
页码:30 / 35
页数:6
相关论文
共 50 条
  • [21] Diagnosis of cavitation inception in water hydraulic piston pump
    Zhou, H
    Yang, HY
    [J]. SIXTH SCANDINAVIAN INTERNATIONAL CONFERENCE ON FLUID POWER, VOLS 1 AND 2, 1999, : 129 - 138
  • [22] Catastrophe analysis of the water mist fire suppression process
    School of Astronautics, Beijing University of Aeronautics and Astronautics, Beijing 100191, China
    [J]. Beijing Hangkong Hangtian Daxue Xuebao, 3 (340-343):
  • [23] Effectiveness of Swirl Water Mist Nozzles for Fire Suppression
    Kraus-Namrozy, Natalia
    Brzezinska, Dorota
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (23)
  • [24] Fire suppression mechanisms of solid fires with water mist
    State Key Laboratory of Fire Science, University of Science and Technology of China, Hefei 230026, China
    [J]. Ranshao Kexue Yu Jishu, 2007, 1 (40-44):
  • [25] A Review of Additives for Water Mist Fire Suppression Systems
    Robinet, Antonin
    Chetehouna, Khaled
    [J]. FIRE TECHNOLOGY, 2024, 60 (05) : 2923 - 2961
  • [26] Fire suppression performance of water mist systems with additives
    Kim, AK
    [J]. PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL II, PT A AND B, 2000, 2 : 561 - 566
  • [27] Suppression of pool fire in a large enclosure with water mist
    Lal, Suresh
    Gupta, Meenakshi
    Kushari, A.
    Kapoor, J. C.
    Maji, S.
    [J]. INTERNATIONAL JOURNAL OF SPRAY AND COMBUSTION DYNAMICS, 2013, 5 (03) : 181 - 199
  • [28] Influence of additives on the fire suppression performance of water mist
    [J]. Jiang, Juncheng, 1600, China University of Mining and Technology (43):
  • [29] Improving fire suppression of water mist by chemical additives
    Chow, W. K.
    Jiang, Z.
    Li, S. F.
    Han, D. L.
    [J]. POLYMER-PLASTICS TECHNOLOGY AND ENGINEERING, 2007, 46 (01) : 51 - 60
  • [30] Numerical Simulation on Water Mist Fire Suppression System Operation in Typical Environment
    Liu, Peng
    [J]. THERMAL, POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 732-733 : 491 - 494