Research of a Water Hydraulic Piston Pump Applied for Water Mist Fire Suppression System

被引:0
|
作者
Zhang Zuti [1 ]
Qu Xuliang [1 ]
Luo Xiaohui [1 ]
Cao Shuping [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Mech Sci & Engn, Wuhan 430074, Hubei, Peoples R China
关键词
piston pump; water mist fire suppression; pressure pulsation;
D O I
暂无
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Fire is one of the fatal threats in manned spacecraft, water mist fire suppression technology has become one of the most important methods to preventing fires. As the main motive components, high pressure water hydraulic piston pump is very important for the development of water mist fire suppression technology. A novel crankshaft piston pump was studied through simulations and experiments in this paper. Furthermore, an attenuator was designed and utilized to reduce the pressure pulsation for the improvement of the performance of the piston pump. Analysis results show that the pump has many essential advantages, such as little lateral force, low PV value, good friction and wear conditions, as well as high volumetric efficiency. In addition, the performances of the pump were obtained through simulations using AMESim. Simulation results indicated that the piston pump has a good flow rate property. The flow rate is well in agreement with the theoretic design and it reaches to 235L/min. However, the flow pulsation unavoidably occurs, and it further causes pressure pulsation. Generally, the pressure pulsation frequency is the product of the shaft rotation frequency and the piston number. Fortunately, the utilization of attenuator could effectively reduce the pressure pulsation, so that the performance of the piston pump is well improved. The pressure pulsation ratio could be reduced to 1%. The new type crankshaft piston pump with low pressure pulsation is helpful to the development of water hydraulic technology and the water mist fire suppression system.
引用
收藏
页码:30 / 35
页数:6
相关论文
共 50 条
  • [11] Thermodynamic modeling, simulation and experiments of a water hydraulic piston pump in water hydraulic variable ballast system
    Liu, Yinshui
    Li, Donglin
    Tang, Zhenyu
    Deng, Yipan
    Wu, Defa
    [J]. OCEAN ENGINEERING, 2017, 138 : 35 - 44
  • [12] Experimental Research of the Hydrodynamic Processes of an Axial Piston Water Hydraulic Pump
    Todic, Nenad
    Savic, Slobodan
    Gordic, Dusan
    Petrovic, Radovan
    [J]. MACHINES, 2022, 10 (09)
  • [13] Water mist suppression of a turbulent line fire
    White, James P.
    Verma, Salman
    Keller, Elizabeth
    Hao, Ailing
    Trouve, Arnaud
    Marshall, Andre W.
    [J]. FIRE SAFETY JOURNAL, 2017, 91 : 705 - 713
  • [14] Experimental and numerical study on water mist suppression system on room fire
    Yang, Peizhong
    Liu, Tao
    Qin, Xian
    [J]. BUILDING AND ENVIRONMENT, 2010, 45 (10) : 2309 - 2316
  • [15] Possibility of using water mist fire suppression system in Hong Kong
    Chow, W. K.
    Chan, L. Y.
    [J]. JOURNAL OF ENGINEERING DESIGN AND TECHNOLOGY, 2011, 9 (02) : 157 - 163
  • [16] Research on effects of port plate structure on water hammering of water axial piston hydraulic pump
    Chen, Jingtian
    Tang, Qunguo
    Zhao, Guiling
    Feng, Xiang
    [J]. PROCEEDINGS OF THE SEVENTH INTERNATIONAL CONFERENCE ON FLUID POWER TRANSMISSION AND CONTROL, 2009, : 788 - 791
  • [17] Experimental and Numerical Study of Water Mist Fire Suppression System Effectiveness on Shielded Fire
    Kuswantoro
    Nugroho, Y. S.
    [J]. 3RD INTERNATIONAL TROPICAL RENEWABLE ENERGY CONFERENCE SUSTAINABLE DEVELOPMENT OF TROPICAL RENEWABLE ENERGY (I-TREC 2018), 2018, 67
  • [18] Research and simulation on valve plate of water hydraulic axial piston pump (motor)
    Nie, S.-L.
    Li, Z.-Y.
    [J]. Jixie Kexue Yu Jishu/Mechanical Science and Technology, 2001, 20 (03): : 407 - 409
  • [19] The interaction of thermal radiation and water mist in fire suppression
    Yang, WH
    Parker, T
    Ladouceur, HD
    Kee, RJ
    [J]. FIRE SAFETY JOURNAL, 2004, 39 (01) : 41 - 66
  • [20] Scaling Study of Tunnel Fire Suppression by Water Mist
    Zhu Wei
    Chen Luyi
    [J]. PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL VII, PTS A AND B, 2008, 7 : 875 - 879