Verification of step-and-shoot IMRT delivery using a fast video-based electronic portal imaging device

被引:33
|
作者
Zeidan, OA [1 ]
Li, JG [1 ]
Ranade, M [1 ]
Stell, AM [1 ]
Dempsey, JF [1 ]
机构
[1] Univ Florida, Dept Radiat Oncol, Gainesville, FL 32610 USA
关键词
EPID; IMRT; MLC; fluence; CCD camera; IMRT treatment plan verification;
D O I
10.1118/1.1644518
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We present an investigation into the use of a fast video-based electronic portal-imaging device (EPID) to study intensity modulated radiation therapy (IMRT) delivery. The aim of this study is to test the feasibility of using an EPID system to independently measure the orchestration of collimator leaf motion and beam fluence; simultaneously measuring both the delivered field fluence and shape as it exits the accelerator head during IMRT delivery. A fast EPID that consists of a terbium-doped gadolinium oxysulphide (GdO2S:Tb) scintillator coupled with an inexpensive commercial 30 frames-per-second (FPS) CCD-video recorder (16.7 ms shutter time) was employed for imaging IMRT delivery. The measurements were performed on a Varian 2100 C/D linear accelerator equipped with a 120-leaf multileaf-collimator (MLQ. A characterization of the EPID was performed that included measurements of spatial resolution, linac pulse-rate dependence, linear output response, signal uniformity, and imaging artifacts. The average pixel intensity for fields imaged with the EPID was found to be linear in the delivered monitor units of static non-lMRT fields between 3 X 3 and 15 X 15 cm(2). A systematic increase of the average pixel intensity was observed with increasing field size, leading to a maximum variation of 8%. Deliveries of a clinical step-andshoot mode leaf sequence were imaged at 600 MU/min. Measurements from this IMRT delivery were compared with experimentally validated MLC controller log files and were found to agree to within 5%. An analysis of the EPID image data allowed identification of three types of errors: (1) 5 out of 35 segments were undelivered; (2) redistributing all of the delivered segment MUs; and (3) leaf movement during segment delivery. Measurements with the EPID at lower dose rates showed poor agreement with log files due to an aliasing artifact. The study was extended to use a highspeed camera (1-1000 FPS and 10 mus shutter time) with our EPID to image the same delivery to demonstrate the feasibility of imaging without aliasing artifacts. High-speed imaging was shown to be a promising direction toward validating IMRT deliveries with reasonable image resolution and noise. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:463 / 476
页数:14
相关论文
共 50 条
  • [41] Radiotherapy delivery error detection with electronic portal imaging device (EPID)-based in vivo dosimetry
    Yang, Xueying
    Geng, Lisheng
    Huang, David
    Li, Kaiwen
    Zhuang, Hongqing
    Cai, Jing
    Yang, Ruijie
    CHINESE MEDICAL JOURNAL, 2023, 136 (08) : 998 - 1000
  • [42] A test tool for the visual verification of light and radiation fields using film or an electronic portal imaging device
    Dunscombe, P
    Humphreys, S
    Leszczynski, K
    MEDICAL PHYSICS, 1999, 26 (02) : 239 - 243
  • [43] A method for geometrical verification of dynamic intensity modulated radiotherapy using a scanning electronic portal imaging device
    Ploeger, LS
    Smitsmans, MHP
    Gilhuijs, KGA
    van Herk, M
    MEDICAL PHYSICS, 2002, 29 (06) : 1071 - 1079
  • [44] Verification of milled two-dimensional photon compensating filters using an electronic portal imaging device
    Low, DA
    Li, ZF
    Klein, EE
    MEDICAL PHYSICS, 1996, 23 (06) : 929 - 938
  • [45] Fast 3D dosimetric verifications based on an electronic portal imaging device using a GPU calculation engine
    Jinhan Zhu
    Lixin Chen
    Along Chen
    Guangwen Luo
    Xiaowu Deng
    Xiaowei Liu
    Radiation Oncology, 10
  • [46] Fast 3D dosimetric verifications based on an electronic portal imaging device using a GPU calculation engine
    Zhu, Jinhan
    Chen, Lixin
    Chen, Along
    Luo, Guangwen
    Deng, Xiaowu
    Liu, Xiaowei
    RADIATION ONCOLOGY, 2015, 10
  • [47] Treatment planning of VMAT and step-and-shoot IMRT delivery techniques for single fraction spine SBRT: An intercomparative dosimetric analysis and phantom-based quality assurance measurements
    Ouyang, Zi
    LaHurd, Danielle, V
    Balagamwala, Ehsan H.
    Chao, Samuel T.
    Suh, John H.
    Xia, Ping
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (01): : 62 - 68
  • [48] Accuracy of the dose delivery in prostate cancer patients-using an electronic portal imaging device (EPID)
    Mahdavi, S. R.
    Gharehbagh, E. Jazayeri
    Mofid, B.
    Jafari, A. H.
    Nikoofar, A. R.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2017, 15 (01): : 39 - 47
  • [49] Real-Time Verification and Error Detection for MLC Tracking Deliveries Using An Electronic Portal Imaging Device
    Zwan, B. J.
    Colvill, E.
    Booth, J.
    O'Connor, D. J.
    Keall, P.
    Greer, P. B.
    MEDICAL PHYSICS, 2016, 43 (06) : 3856 - 3857
  • [50] The new development of positioning verification system with using electronic portal imaging device and radiation therapy LAN.
    Kamikonya, N
    Tsuboi, K
    Izumi, M
    Nakao, N
    CAR '98 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1998, 1165 : 971 - 971