Verification of step-and-shoot IMRT delivery using a fast video-based electronic portal imaging device

被引:33
|
作者
Zeidan, OA [1 ]
Li, JG [1 ]
Ranade, M [1 ]
Stell, AM [1 ]
Dempsey, JF [1 ]
机构
[1] Univ Florida, Dept Radiat Oncol, Gainesville, FL 32610 USA
关键词
EPID; IMRT; MLC; fluence; CCD camera; IMRT treatment plan verification;
D O I
10.1118/1.1644518
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We present an investigation into the use of a fast video-based electronic portal-imaging device (EPID) to study intensity modulated radiation therapy (IMRT) delivery. The aim of this study is to test the feasibility of using an EPID system to independently measure the orchestration of collimator leaf motion and beam fluence; simultaneously measuring both the delivered field fluence and shape as it exits the accelerator head during IMRT delivery. A fast EPID that consists of a terbium-doped gadolinium oxysulphide (GdO2S:Tb) scintillator coupled with an inexpensive commercial 30 frames-per-second (FPS) CCD-video recorder (16.7 ms shutter time) was employed for imaging IMRT delivery. The measurements were performed on a Varian 2100 C/D linear accelerator equipped with a 120-leaf multileaf-collimator (MLQ. A characterization of the EPID was performed that included measurements of spatial resolution, linac pulse-rate dependence, linear output response, signal uniformity, and imaging artifacts. The average pixel intensity for fields imaged with the EPID was found to be linear in the delivered monitor units of static non-lMRT fields between 3 X 3 and 15 X 15 cm(2). A systematic increase of the average pixel intensity was observed with increasing field size, leading to a maximum variation of 8%. Deliveries of a clinical step-andshoot mode leaf sequence were imaged at 600 MU/min. Measurements from this IMRT delivery were compared with experimentally validated MLC controller log files and were found to agree to within 5%. An analysis of the EPID image data allowed identification of three types of errors: (1) 5 out of 35 segments were undelivered; (2) redistributing all of the delivered segment MUs; and (3) leaf movement during segment delivery. Measurements with the EPID at lower dose rates showed poor agreement with log files due to an aliasing artifact. The study was extended to use a highspeed camera (1-1000 FPS and 10 mus shutter time) with our EPID to image the same delivery to demonstrate the feasibility of imaging without aliasing artifacts. High-speed imaging was shown to be a promising direction toward validating IMRT deliveries with reasonable image resolution and noise. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:463 / 476
页数:14
相关论文
共 50 条
  • [31] Verification of MLC Position Using Electric Portal Imaging Device During VMAT Delivery
    Hashimoto, M.
    Haga, A.
    Takahashi, R.
    Nakajima, M.
    Hashimoto, T.
    Saotome, S.
    Sato, T.
    Nakagawa, K.
    Kozuka, T.
    Oguchi, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S768 - S769
  • [32] Intensity modulated radiation therapy (IMRT) verification using the frame averaging feature of Varian Mark II electronic portal imaging device (EPID)
    Chang, J
    Mageras, G
    Ling, CC
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 2059 - 2062
  • [33] Leaf Position Verification during Dynamic Beam Delivery of Volumetric Modulated Arc Therapy Using Electronic Portal Imaging Device
    Sarkar, B.
    Manikandan, A.
    Holla, R.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [34] Assessing radiation and light field congruence with a video based electronic portal imaging device
    Luchka, K
    Chen, D
    Shalev, S
    Gluhchev, G
    Rajapakshe, R
    MEDICAL PHYSICS, 1996, 23 (07) : 1245 - 1252
  • [35] Clinical Feasibility of Using an Electronic Portal Imaging Device for Position Verification during Conventional Radiotherapy
    Shen, Yuxiaotong
    Zhang, Jie
    Ge, Yun
    Chen, Ying
    Li, Haiwei
    Sun, Wei
    Ji, Mingxi
    Wei, Quanbo
    Cai, Jing
    Li, Bing
    2016 IEEE 10TH INTERNATIONAL CONFERENCE ON NANO/MOLECULAR MEDICINE AND ENGINEERING (NANOMED), 2016, : 99 - 103
  • [36] Set-up verification on a belly-board device using electronic portal imaging
    Roels, Sarah
    Verstraete, Jan
    Haustermans, Karin
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2007, 6 (02) : 73 - 82
  • [37] Research on the correction method for radiotherapy verification plans based on displaced electronic portal imaging device
    Guo, Jian
    Zhou, Leyuan
    Zeng, Haibin
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (08):
  • [38] SIFT: A method to verify the IMRT fluence delivered during patient treatment using an electronic portal imaging device
    Vieira, SC
    Dirkx, MLP
    Heijmen, BJM
    de Boer, HCJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (03): : 981 - 993
  • [39] Radiotherapy delivery error detection with electronic portal imaging device (EPID)-based in vivo dosimetry
    Yang Xueying
    Geng Lisheng
    Huang David
    Li Kaiwen
    Zhuang Hongqing
    Cai Jing
    Yang Ruijie
    中华医学杂志英文版, 2023, 136 (08)
  • [40] Geometrical Verification of Real-Time Tumor Tracking Using Electronic Portal Imaging Device (EPID)
    Han-Oh, Y.
    Yi, B.
    Berman, B.
    Yu, C.
    MEDICAL PHYSICS, 2009, 36 (06)