Accuracy of the dose delivery in prostate cancer patients-using an electronic portal imaging device (EPID)

被引:6
|
作者
Mahdavi, S. R. [1 ]
Gharehbagh, E. Jazayeri [2 ]
Mofid, B. [3 ]
Jafari, A. H. [4 ]
Nikoofar, A. R. [5 ]
机构
[1] Iran Univ Med Sci, Dept Med Phys, Tehran, Iran
[2] Univ Tehran Med Sci, Sch Allied Hlth Sci, Dept Radiol & Radiotherapy Technol, Tehran, Iran
[3] Shahid Beheshti Univ Med Sci, Dept Radiotherapy, Tehran, Iran
[4] Tehran Univ Medial Sci, Res Ctr Biomed Technol & Robot, Tehran, Iran
[5] Iran Univ Med Sci, Dept Radiotherapy, Tehran, Iran
来源
关键词
Prostate cancer; EPID; systematic errors; random errors; RADIOPAQUE MARKERS; ORGAN MOTION; TREATMENT VERIFICATION; STANDARD RADIOTHERAPY; ROUTINE RADIOTHERAPY; GUIDED RADIOTHERAPY; PELVIC RADIOTHERAPY; IRRADIATION; POSITION; LOCALIZATION;
D O I
10.18869/acadpub.ijrr.15.1.39
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: To correct patient positioning errors (setup errors) during prostate cancer treatment using EPID and fiducial gold markers, to improve the accuracy of the dose delivery in these patients. Materials and Methods: Fifteen patients with localized prostate carcinoma after implantation of fiducial gold markers in their prostate gland underwent the five-field IMRT planning technique. The plan was prepared in accordance with ICRU 50 guidance (PTV to receive 95-107% dose). The software program reconstructed the three-dimensional position of the markers from the different Beams Eye Views (BEV). The discrepancies of the seeds' positions (prostate surrogate) between plan and daily images were calculated three dimensionally. Then, necessary corrections were applied to match the prostate fiducial markers in the portal image with the BEV image in the planned one by moving the couch in the X, Y and Z directions. Results: Data from 15 patients and 469 fractions of radiotherapy were analyzed in this study. Two sets of data were available from EPID software before and after 3D set-up corrections. The mean of the population displacement in Left /Right (L/R), Anterior/Posterior (A/P) and Crania/Caudal (C/C) directions were 0.5,-1.0 and 2.4mm before, and-0.1,-0.5 and 0.9mm after corrections, respectively. The systematic and random errors for the measured populations in the three mentioned directions were 2.4, 2.7 and 2mm and 6.4, 5.9 and 6.1mm before corrections, and 1.1, 2.4 and 1.4mm and 3.8, 3.9 and 3.6mm after corrections, correspondingly. Conclusion: This study provides further evidence that using gold markers in the prostate improves dose delivery to the prostate. Also, it has been demonstrated that the EPID can be a powerful tool in the reduction of treatment setup errors and the quality assurance and verification of complex treatments.
引用
收藏
页码:39 / 47
页数:9
相关论文
共 50 条
  • [1] Transit Dosimetry for Verification of Dose Delivery Using Electronic Portal Imaging Device (EPID)
    Baek, T.
    Chung, E.
    Lee, S.
    Yoon, M.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 301 - 301
  • [2] Transit dosimetry with an electronic portal imaging device (EPID) for 115 prostate cancer patients
    Pasma, KL
    Kroonwijk, M
    Quint, S
    Visser, AG
    Heijmen, BJM
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (05): : 1297 - 1303
  • [3] PORTAL DOSE MEASUREMENT IN RADIOTHERAPY USING AN ELECTRONIC PORTAL IMAGING DEVICE (EPID)
    HEIJMEN, BJM
    PASMA, KL
    KROONWIJK, M
    ALTHOF, VGM
    DEBOER, JCJ
    VISSER, AG
    HUIZENGA, H
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (11): : 1943 - 1955
  • [4] In vivo dosimetry for prostate cancer patients using an electronic portal imaging device (EPID); demonstration of internal organ motion
    Kroonwijk, M
    Pasma, KL
    Quint, S
    Koper, PCM
    Visser, AG
    Heijmen, BJM
    [J]. RADIOTHERAPY AND ONCOLOGY, 1998, 49 (02) : 125 - 132
  • [5] Improvement of radiotherapy treatment delivery accuracy using an electronic portal imaging device
    Dirkx, M. L. P.
    de Boer, J. C. J.
    Heijmen, B. J. M.
    [J]. RADIATION PROTECTION DOSIMETRY, 2006, 121 (01) : 70 - 79
  • [6] Assement of the accuracy of treatment fields with electronic portal imaging device (EPID) in a breast irradiation
    Cetinayak, H. O.
    Gorken, I.
    Eyiler, F.
    Dag, N.
    Bayraktar, F.
    Sengunay, F.
    Yigitbasi, L.
    Ates, L.
    Alanyali, H.
    Kinay, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S278 - S279
  • [7] In Vivo 3D Dose Verification for IMRT Using Electronic Portal Imaging Device (EPID)
    Chang, C.
    Anderson, N. G.
    Zhu, T. C.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [8] Dose verifications by use of liquid ionization chamber of an electronic portal imaging device (EPID).
    Tateoka K.
    Oouchi A.
    Nakata K.
    Hareyama M.
    [J]. Radiological Physics and Technology, 2008, 1 (2) : 171 - 177
  • [9] Repositining of prostate cancer patients, using implanted gold seeds into prostate and electronic portal imaging device
    Coskun, Nedret
    Olacak, Nezahat
    Hoca, Sinan
    Ozkok, Serdar
    Aras, Arif Bulent
    [J]. TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2013, 28 (01): : 23 - 35
  • [10] Using an electronic portal imaging device (EPID) for routine geometrical LINAC verifications
    Bejarano, M. Benito
    Beltran, F. Saez
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S253 - S254