Intraoperative Imaging With a 3D C-Arm System After Zygomatico-Orbital Complex Fracture Reduction

被引:76
|
作者
Wilde, Frank [1 ,2 ]
Lorenz, Kai [2 ,3 ]
Ebner, Ann-Kathrin [4 ]
Krauss, Oliver [2 ,5 ]
Mascha, Frank [1 ,2 ]
Schramm, Alexander [1 ,2 ]
机构
[1] Mil Hosp Ulm, Dept Oral & Maxillofacial Surg, D-89081 Ulm, Germany
[2] Univ Ulm, Acad Hosp, D-89081 Ulm, Germany
[3] Mil Hosp Ulm, Dept Otolaryngol Head & Neck Surg, D-89081 Ulm, Germany
[4] Univ Ulm, Dept Dent, D-89081 Ulm, Germany
[5] Mil Hosp Ulm, Dept Ophthalmol, D-89081 Ulm, Germany
关键词
COMPUTED-TOMOGRAPHY; BLINDNESS; SURGERY; TRAUMA;
D O I
10.1016/j.joms.2012.10.031
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: During the repair of zygomatico-orbital complex (ZMC) fractures, the lateral orbital wall and/or the orbital floor is often reduced by merely reducing the zygoma. Intraoperative 3D imaging can help surgeons decide whether the orbit must be reconstructed as well. The purpose of this study was therefore to assess the usefulness of intraoperative 3D C-arm imaging in evaluating the adequacy of fracture reduction. Methods: A total of 21 patients with unilateral ZMC fractures were enrolled in this retrospective study. Four fractures were treated with a closed reduction technique. Seventeen fractures were repaired with open reduction and internal fixation of the zygomaticomaxillary buttress area. Intraoperative 3D C-arm imaging was performed in all cases. All patients underwent postoperative computed tomography and a clinical examination no earlier than 5 months after the procedure. Results: After reduction of the ZMC fractures, intraoperative 3D scans showed inadequate repair of the orbital floor in 2 patients and inadequate repair of the lateral orbit in 1 patient. Zygoma and zygomatic arch fracture reduction had to be corrected in 1 further case. The other 17 patients did not need an additional procedure. Postoperative imaging showed that no patient required a secondary operation. No postoperative diplopia or enophthalmos developed in any patient. Conclusions: Intraoperative 3D C-arm imaging appears to be an effective tool for evaluating ZMC fracture reduction. It helps avoid additional procedures and thus helps reduce morbidity. In addition, there appears to be no need for postoperative imaging. (C) 2013 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 71:894-910, 2013
引用
收藏
页码:894 / 910
页数:17
相关论文
共 50 条
  • [21] Development of an intraoperative 3D C-arm technique for torsion control of femur fractures: a cadaver study
    T. Stubig
    H. Aidarous
    A. Khalifa
    M. Omar
    C. Krettek
    T. Omar Pacha
    Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 1739 - 1743
  • [22] 3D C-arm navigated acromioclavicular joint stabilization
    Alexander Böhringer
    Florian Gebhard
    Christoph Dehner
    Alexander Eickhoff
    Raffael Cintean
    Carlos Pankratz
    Konrad Schütze
    Archives of Orthopaedic and Trauma Surgery, 2024, 144 : 601 - 610
  • [23] 3D C-arm navigated acromioclavicular joint stabilization
    Boehringer, Alexander
    Gebhard, Florian
    Dehner, Christoph
    Eickhoff, Alexander
    Cintean, Raffael
    Pankratz, Carlos
    Schuetze, Konrad
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (02) : 601 - 610
  • [24] Technical Assessment of Dose and 3D Imaging Performance for a New Mobile Isocentric C-Arm for Intraoperative Cone-Beam CT
    Sheth, N.
    De Silva, T.
    Uneri, A.
    Ketcha, M.
    Han, R.
    Vijayan, R.
    Kleinszig, G.
    Vogt, S.
    Siewerdsen, J.
    MEDICAL PHYSICS, 2019, 46 (06) : E111 - E111
  • [25] Radiofrequency ablation under 3D intraoperative Iso-C C-arm navigation for the treatment of osteoid osteomas
    Yu, Feng
    Niu, Xiao-hui
    Zhang, Qing
    Zhao, Hai-tao
    Xu, Li-hui
    Deng, Zhi-ping
    BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1056):
  • [26] Automated Digital Image Optimisation in Intraoperative 2D and 3D Imaging Using a Mobile C-Arm With Flat-Panel Detector
    Groh, J.
    Perl, M.
    Braeuer, L.
    Stadthalter, H.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2025, 21 (02):
  • [27] 3D imaging with an isocentric mobile C-arm - Comparison of image quality with spiral CT
    Kotsianos, D
    Wirth, S
    Fischer, T
    Euler, E
    Rock, C
    Linsenmaier, U
    Pfeifer, KJ
    Reiser, M
    EUROPEAN RADIOLOGY, 2004, 14 (09) : 1590 - 1595
  • [28] 3D X-ray imaging of human bones using a mobile C-arm
    Lütjens, J
    Koppe, R
    Klotz, E
    Grass, M
    Rasche, V
    CARS 2002: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2002, : 1016 - 1016
  • [29] Artifacts Reduction in Low-Contrast Neurological Imaging with C-arm System
    Xia, Dan
    Chang, Yu-Bing
    Siddiqui, Adnan H.
    Zhang, Zheng
    Manak, Joe
    Sidky, Emil Y.
    Pan, Xiaochuan
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [30] 3D reconstruction from projection matrices in a C-arm based 3D-angiography system
    Navab, N
    Bani-Hashemi, A
    Nadar, MS
    Wiesent, K
    Durlak, P
    Brunner, T
    Barth, K
    Graumann, R
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI'98, 1998, 1496 : 119 - 129