3D C-arm navigated acromioclavicular joint stabilization

被引:2
|
作者
Boehringer, Alexander [1 ]
Gebhard, Florian [1 ]
Dehner, Christoph [1 ]
Eickhoff, Alexander [1 ]
Cintean, Raffael [1 ]
Pankratz, Carlos [1 ]
Schuetze, Konrad [1 ]
机构
[1] Ulm Univ, Dept Trauma Hand & Reconstruct Surg, Albert Einstein Allee 23, D-89081 Ulm, Germany
关键词
Tossy; Rockwood; AC joint separation; Tightrope; 3D C-arm navigation; Shoulder imaging; HOOK PLATE; RECONSTRUCTION; DISLOCATION; STABILITY; ISO-C-3D; REPAIR;
D O I
10.1007/s00402-023-05112-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionSurgical treatment options for acromioclavicular joint separations are varied. Frequently, suspension devices (SD) are inserted for stabilization under arthroscopic view. This study investigates the feasibility and accuracy of three-dimensional (3D) digital-volume-tomography (DVT) C-arm navigated implantation with regard to the general trend toward increasingly minimally invasive procedures.Materials and methodsThe implantation of a TightRope (R) suture button system (SD) via a navigated vertical drill channel through the clavicle and coracoid was investigated in 10 synthetic shoulder models with a mobile isocentric C-arm image intensifier setup in the usual parasagittal position. Thereby, in addition the placement of an additive horizontal suture cerclage via a navigated drill channel through the acromion was assessed.ResultsAll vertical drill channels in the Coracoclavicular (CC) direction could be placed in a line centrally through the clavicle and the coracoid base. The horizontal drill channels in the Acromioclavicular (AC) direction ran strictly in the acromion, without affecting the AC joint or lateral clavicle. All SD could be well inserted and anchored. After tensioning and knotting of the system, the application of the horizontal AC cerclage was easily possible. The image quality was good and all relevant structures could be assessed well.ConclusionIntraoperative 3D DVT imaging of the shoulder joint using a mobile isocentric C-arm in the usual parasagittal position to the patient is possible. Likewise, DVT navigated SD implantation at the AC joint in CC and AC direction on a synthetic shoulder model. By combining both methods, the application in vivo could be possible. Further clinical studies on feasibility and comparison with established methods should be performed.
引用
收藏
页码:601 / 610
页数:10
相关论文
共 50 条
  • [1] 3D C-arm navigated acromioclavicular joint stabilization
    Alexander Böhringer
    Florian Gebhard
    Christoph Dehner
    Alexander Eickhoff
    Raffael Cintean
    Carlos Pankratz
    Konrad Schütze
    [J]. Archives of Orthopaedic and Trauma Surgery, 2024, 144 : 601 - 610
  • [2] The Method of 3D C-arm Navigated AC Joint Stabilization-Surgical Technique
    Boehringer, Alexander
    Pankratz, Carlos
    Eickhoff, Alexander
    Gebhard, Florian
    Schuetze, Konrad
    [J]. SURGICAL TECHNIQUES DEVELOPMENT, 2024, 13 (02): : 214 - 226
  • [3] 3D C-arm navigated suture button implantation for AC joint dislocations - the pilot study
    Boehringer, Alexander
    Gebhard, Florian
    Dehner, Christoph
    Eickhoff, Alexander
    Cintean, Raffael
    Pankratz, Carlos
    Schuetze, Konrad
    [J]. EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2024,
  • [4] Intraoperative Computed Tomography Versus 3D C-Arm Imaging for Navigated Spinal Instrumentation
    Hecht, Nils
    Yassin, Hadya
    Czabanka, Marcus
    Foehre, Bettina
    Arden, Klaus
    Liebig, Thomas
    Vajkoczy, Peter
    [J]. SPINE, 2018, 43 (05) : 370 - 377
  • [5] Intraoperative 3D imaging with a standard c-arm
    Tita, R.
    Lueth, T. C.
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2007, 2 : S206 - S208
  • [6] 3D soft tissue imaging with a mobile C-arm
    Ritter, Dieter
    Orman, Jasmina
    Schmidgunst, Christian
    Graumann, Rainer
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2007, 31 (02) : 91 - 102
  • [7] A method for extracting 3D information of cylinder in C-arm image
    Wu, Jian
    [J]. BMEI 2008: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOL 2, 2008, : 544 - +
  • [8] Intraoperative 3D C-arm imaging. State of the art
    von Recum, J.
    Wendl, K.
    Vock, B.
    Gruetzner, P. A.
    Franke, J.
    [J]. UNFALLCHIRURG, 2012, 115 (03): : 196 - 201
  • [9] Parallelizable 3D statistical reconstruction for C-arm tomosynthesis system
    Wang, BL
    Barner, K
    Lee, D
    [J]. MEDICAL IMAGING 2005: IMAGE PROCESSING, PT 1-3, 2005, 5747 : 2171 - 2182
  • [10] Mobile C-arm 3D Reconstruction in the Presence of Uncertain Geometry
    Rottman, Caleb
    McBride, Lance
    Cheryauka, Arvidas
    Whitaker, Ross
    Joshi, Sarang
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2015, PT II, 2015, 9350 : 692 - 699