The Method of 3D C-arm Navigated AC Joint Stabilization-Surgical Technique

被引:0
|
作者
Boehringer, Alexander [1 ]
Pankratz, Carlos [1 ]
Eickhoff, Alexander [1 ]
Gebhard, Florian [1 ]
Schuetze, Konrad [1 ]
机构
[1] Univ Ulm, Dept Trauma Hand & Reconstruct Surg, Albert Einstein Allee 23, D-89081 Ulm, Germany
来源
SURGICAL TECHNIQUES DEVELOPMENT | 2024年 / 13卷 / 02期
关键词
3D C-arm imaging; computer navigation; shoulder TightRope; AC joint; Tossy; Rockwood; ROCKWOOD CLASSIFICATION; HOOK PLATE; RECONSTRUCTION; COMPLICATIONS; SEPARATIONS; DISLOCATION; INSTABILITY; REDUCTION; STABILITY; DIAGNOSIS;
D O I
10.3390/std13020014
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The arthroscopically assisted stabilization of AC joint dislocations with a suture button system is an established procedure that is widely and successfully used in everyday practice. The main advantages of this one-step method are the minimally invasive procedure and the anatomical reconstruction of the ruptured coracoclavicular ligaments with a permanent implant. With this technical note study, for the first time, the new method of navigated suture button implantation in everyday clinical practice is described with the future goal of further reducing invasiveness and increasing precision. Materials and Methods: The surgical technique is explained using precise descriptions and illustrations, photos, X-rays, and 3D reconstructions based on clinical cases. The step-by-step system setup and patient positioning, AC joint reduction and retention, 3D scan and drill tunnel planning, stab incision and Kirschner wire navigation, and cannulated drilling and implant positioning, as well as closure and documentation are described in detail. Results: The standard coracoclavicular stabilization of AC joint dislocations with the 3D C-arm navigated suture button method is described in detail. Furthermore, the feasibility of an additive horizontal acromioclavicular suture cerclage, the implantation of an additional coracoclavicular suture button system, and the single-stage cannulated screw fixation of non-displaced fractures is demonstrated. Conclusion: The navigated suture button method aims to be simple, safe, minimally invasive, and precise. Prospective clinical studies with a long follow-up should be carried out to determine the clinical and radiological outcome in comparison with current methods.
引用
收藏
页码:214 / 226
页数:13
相关论文
共 50 条
  • [1] 3D C-arm navigated acromioclavicular joint stabilization
    Boehringer, Alexander
    Gebhard, Florian
    Dehner, Christoph
    Eickhoff, Alexander
    Cintean, Raffael
    Pankratz, Carlos
    Schuetze, Konrad
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (02) : 601 - 610
  • [2] 3D C-arm navigated acromioclavicular joint stabilization
    Alexander Böhringer
    Florian Gebhard
    Christoph Dehner
    Alexander Eickhoff
    Raffael Cintean
    Carlos Pankratz
    Konrad Schütze
    [J]. Archives of Orthopaedic and Trauma Surgery, 2024, 144 : 601 - 610
  • [3] 3D C-arm navigated suture button implantation for AC joint dislocations - the pilot study
    Boehringer, Alexander
    Gebhard, Florian
    Dehner, Christoph
    Eickhoff, Alexander
    Cintean, Raffael
    Pankratz, Carlos
    Schuetze, Konrad
    [J]. EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2024,
  • [4] Intraoperative Computed Tomography Versus 3D C-Arm Imaging for Navigated Spinal Instrumentation
    Hecht, Nils
    Yassin, Hadya
    Czabanka, Marcus
    Foehre, Bettina
    Arden, Klaus
    Liebig, Thomas
    Vajkoczy, Peter
    [J]. SPINE, 2018, 43 (05) : 370 - 377
  • [5] A method for extracting 3D information of cylinder in C-arm image
    Wu, Jian
    [J]. BMEI 2008: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOL 2, 2008, : 544 - +
  • [6] Intraoperative 3D imaging with a standard c-arm
    Tita, R.
    Lueth, T. C.
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2007, 2 : S206 - S208
  • [7] A cheap and easy method for 3D C-arm reconstruction using elliptic curves
    Burkhardt, David
    Jain, Ameet
    Fichtinger, Gabor
    [J]. MEDICAL IMAGING 2007: VISUALIZATION AND IMAGE-GUIDED PROCEDURES, PTS 1 AND 2, 2007, 6509
  • [8] 3D soft tissue imaging with a mobile C-arm
    Ritter, Dieter
    Orman, Jasmina
    Schmidgunst, Christian
    Graumann, Rainer
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2007, 31 (02) : 91 - 102
  • [9] Development of an intraoperative 3D C-arm technique for torsion control of femur fractures: a cadaver study
    Stubig, T.
    Aidarous, H.
    Khalifa, A.
    Omar, M.
    Krettek, C.
    Pacha, T. Omar
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (11) : 1739 - 1743
  • [10] Development of an intraoperative 3D C-arm technique for torsion control of femur fractures: a cadaver study
    T. Stubig
    H. Aidarous
    A. Khalifa
    M. Omar
    C. Krettek
    T. Omar Pacha
    [J]. Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 1739 - 1743