Background: The arthroscopically assisted stabilization of AC joint dislocations with a suture button system is an established procedure that is widely and successfully used in everyday practice. The main advantages of this one-step method are the minimally invasive procedure and the anatomical reconstruction of the ruptured coracoclavicular ligaments with a permanent implant. With this technical note study, for the first time, the new method of navigated suture button implantation in everyday clinical practice is described with the future goal of further reducing invasiveness and increasing precision. Materials and Methods: The surgical technique is explained using precise descriptions and illustrations, photos, X-rays, and 3D reconstructions based on clinical cases. The step-by-step system setup and patient positioning, AC joint reduction and retention, 3D scan and drill tunnel planning, stab incision and Kirschner wire navigation, and cannulated drilling and implant positioning, as well as closure and documentation are described in detail. Results: The standard coracoclavicular stabilization of AC joint dislocations with the 3D C-arm navigated suture button method is described in detail. Furthermore, the feasibility of an additive horizontal acromioclavicular suture cerclage, the implantation of an additional coracoclavicular suture button system, and the single-stage cannulated screw fixation of non-displaced fractures is demonstrated. Conclusion: The navigated suture button method aims to be simple, safe, minimally invasive, and precise. Prospective clinical studies with a long follow-up should be carried out to determine the clinical and radiological outcome in comparison with current methods.
引用
收藏
页码:214 / 226
页数:13
相关论文
共 50 条
  • [41] Use of robotic C-arm cone-beam computed tomography in surgical stabilization of rib fractures
    Yen, Ming-Hong
    Liu, Tsu-Hao
    Liu, Jung -Sen
    Yim, Shelly
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 (12):
  • [42] C-arm angiography (DYNA-CT) for 3D Coronary Reconstruction and Myocardial Perfusion Assessment
    Rittger, Harald
    Lauritsch, Guenter
    Brachmann, Johannes
    Rieber, Johannes
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (17) : B93 - B93
  • [43] 3D ablation catheter localisation using individual C-arm x-ray projections
    Haase, C.
    Schaefer, D.
    Doessel, O.
    Grass, M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (22): : 6959 - 6977
  • [44] Online C-arm calibration using a marked guide wire for 3D reconstruction of pulmonary arteries
    Vachon, Etienne
    Miro, Joaquim
    Duong, Luc
    [J]. MEDICAL IMAGING 2017: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2017, 10135
  • [45] 3-D Model Reconstruction from C-arm Images
    Chen, Yan-Ru
    Lin, Huei-Yung
    Wang, Min-Liang
    [J]. 2016 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2016, : 2454 - 2459
  • [46] Automatic bone removal for 3D TACE planning with C-arm CBCT: Evaluation of technical feasibility
    Wang, Zhijun
    Hansis, Eberhard
    Chen, Rongxin
    Duran, Rafael
    Chapiro, Julius
    Sheu, Yun Robert
    Kobeiter, Hicham
    Grass, Michael
    Geschwind, Jean-Francois
    Lin, MingDe
    [J]. MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2016, 25 (03) : 162 - 170
  • [47] Evaluation of a novel C-Arm draping technique to minimize surgical field contamination and surgery time
    Darbandi, Aria
    Pujari, Amit
    Lin, Carol
    [J]. ANZ JOURNAL OF SURGERY, 2021, 91 (7-8) : 1455 - 1461
  • [48] Automatic C-arm Pose Estimation via 2D/3D Hybrid Registration of a Radiographic Fiducial
    Moult, E.
    Burdette, E. C.
    Song, D. Y.
    Abolmaesumi, P.
    Fichtinger, G.
    Fallavollita, P.
    [J]. MEDICAL IMAGING 2011: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2011, 7964
  • [49] Radiofrequency ablation under 3D intraoperative Iso-C C-arm navigation for the treatment of osteoid osteomas
    Yu, Feng
    Niu, Xiao-hui
    Zhang, Qing
    Zhao, Hai-tao
    Xu, Li-hui
    Deng, Zhi-ping
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1056):
  • [50] Comparative irradiation between peroperative 2D C-arm and 3D CBCT in children: a study on phantoms
    Prod'homme, Marc
    Sans-Merce, Marta
    Pitteloud, Nicolas
    Damet, Jerome
    Lascombes, Pierre
    [J]. SWISS MEDICAL WEEKLY, 2018, 148 : 59S - 59S